K200-622 Cabinet Lock Series Installation Instructions HES, Inc. Phoenix, AZ 1.800.626.7590 www.hesinnovations.
External Interface Signals Summary: Lock Signal Name Vin Lock Signal Direction and Wire Color Input, Red/24 AWG Electrical Interface Logic Power to Reader Input Power Active High Unlock Input, Orange/24 AWG Wetted Relay Contact Closure (0–35 VDC) Tamper / Door Position + Output, Yellow/24 AWG Dry Contact (0–35 VDC, <100mA) Open = Unlocked Tamper / Door Position – Output, Blue/24 AWG Dry Contact (0–35 VDC, <100mA) Open = Unlocked Closed = Locked Closed = Locked Wiegand Data 0 Output, Gre
TESTING THE LOCK 1. TEST the lock with a known good credential to confirm it will open as desired when installed. a. REMOVE the cover from the lock body. b. PASS the wire and shaft from the reader through the lock body. NOTE: The wire connector is keyed. c. CONNECT the wire connector from the reader to the socket in the lock compartment. d. CONNECT the 10-position Molex Micro-Fit 3.0 cable between the K200 and the EAC, and ENSURE power is ON. e. PRESENT a credential known to the EAC. f.
MOUNTING THE LOCK NOTE: The K200 reader and lock body can be oriented in several ways to accommodate various cabinets and drawers. When selecting an orientation, it should be noted that some reader orientations may prevent use of the key override function. For example, in the door handing shown here, the key override paddle cannot be accessed in orientation “A”, but it can be accessed in orientations “B,” “C” and “D”. 1. ESTABLISH the horizontal centerline of the latch. a.
2. TRANSFER the location of the inside wall of the cabinet to the door. a. MEASURE the horizontal distance between the inside edge of the cabinet and the door edge. NOTE: The drawn line depicts the location of the strike mounting surface. b. LOCATE the lock centerline notch on the latch and MARK this point on the inside of the cabinet door using a pencil. c. DRAW the horizontal latch centerline from this mark on the inside of the cabinet door and TRANSFER it to the outside of the cabinet door. 3.
4. INSTALL the shaft extension. a. IF the cabinet door thickness is greater than ½” [12.70 mm] (see Table 1), THEN INSTALL the Shaft Extension to the Antenna/Reader to ensure proper engagement into the lock. b. INSTALL the Shaft Extension to the shaft as shown in the figure, and firmly TIGHTEN the screw. Table 1 Door Thickness Extension Shaft Used? 1/16” [1.59 mm] – ½” [12.70 mm] No > ½” [12.70 mm] – 1 ½” [38.10 mm] Yes 5.
. INSTALL the Antenna/Reader. CAUTION Pinching the wires may prevent the Reader and Lock from properly functioning. a. PLACE and HOLD the antenna/reader to the outside of cabinet, routing the wire through the 1/2” [12.70 mm] offset hole, and ENSURE the knob is in the locked position in the vertical. NOTE: Using the table below will help determine the length of the top mount screw needed, based on the thickness of the cabinet door. b.
9. CONNECT the antenna/reader wire to the lock body. NOTE: The antenna/reader wire connector is engineered to fit only one way. a. INSERT the antenna/reader wire connector, ensuring correct orientation b. TUCK excess cable into the lock body. c. ATTACH the cover. Part Number 3085006.001, Rev.
10. CONNECT the 10-position Molex Micro-Fit Cable between the K200 and the EAC. 11. ENSURE the following power cabling guidelines are followed: Wire AWG Supply Voltage Allowed Cable Length (ft.)* 12 872 24 6679 12 548 24 4201 12 345 24 2641 20 AWG 22 AWG 24 AWG * Round trip loss. V = 2 x I x R x xft xft = V / (2 x I x R) 12. POSITION the cable out of the way, as required. 13. PREPARE for the single door strike plate. a.
CAUTION The Installer must ensure that the lock can be opened before closing the cabinet door. 14. INSTALL the single door strike plate. PLACE the strike plate over the pilot holes, and INSERT and TIGHTEN the two screws in the slotted holes. CLOSE the door to verify installation, and ADJUST the strike plate if necessary. INSERT and TIGHTEN the lock down screw on the strike plate. 15. INSTALL for the double-door strike plate mounting bracket.
FCC Statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
(2) cet appareil doit accepter toute interference, y compris des interférences qui peuvent provoquer un fonctionnement indésirable du périphérique. Conformité aux normes CE HES déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 1999/5/CE. For Technical Support please call 1-800-626-7590 Part Number 3085006.001, Rev. A © 2015, Hanchett Entry Systems, Inc., an ASSA ABLOY Group Company.