VENTILATION FAN VFB160D6A3-DGL TABLE OF CONTENTS READ AND SAVE THESE INSTRUCTIONS Address: 46101 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: 1-888-979-9889 – Technical Support 1-877-685-4384 – Customer Sales Support www.deltabreez.
PACKAGE CONTENTS 1 PART DESCRIPTION QTY 1 Fan Body 1 2 Suspension bracket 4 3 6" to 4" adapter 1 4 Grille 1 HARDWARE CONTENTS (Images are to scale) 2 A ×8 Long Wood Screw (Ø4 x 25mm) B ×4 Short Screw (#8-32x1/4”) 3 4 2
GENERAL SAFETY INFORMATION READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter) – protected branch circuit. 1. Make sure that the electric service supply voltage is AC 120V, 60Hz. 8. Do not use this unit with any other solid-state control device.
PREPARATION Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife Helpful Tools (not included): Electric Drill, Drill Bits Proper insulation around the fan to minimize building heat loss and gain. 6” circular duct is recommended for installation. The ducting from this fan to the outside of building has a strong effect on the air flow, noise and energy use of the fan.
WIRING DIAGRAM QUICK CONNECTOR INSTRUCTIONS To be sold only with installation instructions. WARNING: Wiring must comply with all appliable electrical codes. Turn OFF power before removing or installing connectors. Quick connector House wires WARNING: COPPER TO COPPER ONLY. Do not use aluminum wire. Product wires CAUTION: Accessory part (quick connector) should meet installation instructions below. NOTE: The connector is reusable on solid wires of the same wire gauge or smaller.
ASSEMBLY INSTRUCTIONS NEW CONSTRUCTION – ATTACHING TO THE JOIST 1 Joist BEFORE INSTALLATION Turn off power source. Review all safety precautions. 1 1. If spacing between joists is 12 in. apart, use four long wood screws (provided) to attach the fan body 1 to ceiling joists, NO NEED FOR SUSPENSION BRACKETS. A Hardware A Long wood screw 2 1 Fan Body 2. For joist spacing 16 in.- 24 in., insert suspension bracket 2 into the bracket cover on the duct connector side and the back of the fan body 1 .
ASSEMBLY INSTRUCTIONS 3 3. Remove the fan junction box cover a . Using wire nuts (not supplied), connect house wires to fan wires b as shown in the wiring diagram on page 5. 14AWG is the smallest conductor that shall be used for branch-circuit wiring. Reattach fan junction box cover c . b c a 4 4. Connect a 6 in. circular duct a (not supplied) and vent to the outside. Secure it with duct tape (not supplied) or clamp (not supplied) to make the connection secure and air tight. a Joist Joist 5 5.
ASSEMBLY INSTRUCTIONS EXISTING CONSTRUCTION BEFORE INSTALLATION Turn off power source. Review all safety precautions. 1 1. Remove existing fan. 2 2. Measure the opening to ensure it is large enough to accommodate the new fan body (10 1/4 in. x 10 1/4 in.). 3 3. If this fan is not replacing an old fan, be sure to cut a 10 1/4 in. x 10 1/4 in. opening for the fan body 1 . /.4"in. 10 19 10 . n .
ASSEMBLY INSTRUCTIONS Install from below, no need for suspension brackets (no attic access) 4 4. Remove fan unit by removing 3 screws. 5 5. Remove duct connector by removing duct screw. Duct screw 6 6. A piece of wood (not supplied) is screwed in from below through the ceiling board. Suggested size is 1 in. x 3 in. x 14 in. Position the screws far enough away from the edge of the ceiling board that it does not crumble and give way. Put screws in both ends of wood beyond the 10 1/4 in. hole.
ASSEMBLY INSTRUCTIONS 7 7. Remove the fan junction box cover a . Using 2 wire nuts (not supplied), connect house wires to fan wires b a s shown in the wiring diagram on page 5. 14AWG is the smallest conductor that shall be used for branch-circuit wiring. Reattach fan junction box cover c . c a b 8 8. Insert housing can into the ceiling cut out. Secure the housing can from below by using 2 long wood screws through the flange into the wood support and 2 long wood screws through the flange into the joist.
ASSEMBLY INSTRUCTIONS Install from above with suspension brackets (attic accessible) 1 1 Fan Body *ONLY IF UNABLE TO ATTACH DIRECTLY TO JOIST(S) 1. For joist spacing 16 in.- 24 in., insert suspension bracket 2 into the bracket cover on the duct connector side and the back of the fan body 1 . 2 Suspension Bracket Install the suspension brackets to the joists with long wood screw, and secure the suspension brackets to the fan body 1 by using the short screws (provided).
GRILLE INSTALLATION Attach grille 4 by pinching mounting springs a and insert into the narrow rectangular slots in fan body. a 4 OPERATION Turn the POWER switch on to operate at full speed airflow.
CARE AND MAINTENANCE See safety information before proceeding. Routine maintenance should be done at least once a year. • Never use solvents, thinner or harsh chemicals when cleaning the fan. • Do not allow water to enter the motor. • Do not immerse metal parts in water. • Do not immerse resin parts in water over 140º Fahrenheit. 1 Turn off power source. Review all safety precautions. 1. To remove grille 4 , squeeze springs and pull down. 4 2.
TROUBLESHOOTING PROBLEM The fan is not turning on The fan seems louder than it should The fan is not clearing the room POSSIBLE CAUSE CORRECTIVE ACTION 1. Power off 1. Make sure power supply is on. 2. Faulty switch 2. Test or replace switch. 3. Faulty wire connection 3. Check wire in switch box. 1. CFM too great 1. Be sure the CFM rating on the fan matches the size of your room. 2. Damper not working properly or damaged 2. Check damper to ensure it is opening and closing properly.
12 3/8 (314.0) 11 21/32 (295.8) 6 (150) DIMENSIONS 7 7/8 (200) 1 9/16 (40.0) 12 3/8 (314.0) Unit: Inches(mm) 9 21/32 (245.4) 3 3/4 (94.4) PRODUCT SPECIFICATIONS Model No. Voltage (V) Frequency (Hz) Air Flow @ 0.1"SP (CFM) Power @ 0.1"SP (W) Max Current (Amps) Weight (lb.) Note VFB160D6A3-DGL 120 60 160 16.4 0.38 10 Single Speed Note: Design and specifications subject to change without notice.
WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase. Limitations and Exclusions 1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer.