Before attempting to clean the xture, disconnect the power to the xture by turning the breaker off or removing the fuse from the fuse box.
To clean the xture, use a dry or slightly dampened clean cloth.
Do not use cleaners with chemicals, solvents, or harsh abrasives, as damage to the xture may occur.
Problem Possible Cause Solution
Lights do not turn on. There is no power.
There is a disconnection or
break in the wire.
The transformer setting is
incorrect.
Check the outlet and ensure that a breaker or GFCI circuit has not been tripped.
Follow the wires from the xture and ensure a continuous connected path back to the
transformer.
Check the settings on the transformer.
Lights icker. There is a loose wire con-
nector to the xture.
Tighten the wire connector and ensure the metal contacts pierce the insulation on the low
voltage cable from the transformer.
Lights icker (all xtures). There is a loose
connection at the
transformer.
Unplug the transformer from the outlet and visually inspect the positive and negative
connecting posts. Each wire should be securely screwed in and not in contact with any
other.
Cable Selection
WHAT IS COVERED
The manufacturer warrants this lighting xture to be free from defects in materials and workmanship for a period of ve (5) years from date of
purchase. This warranty applies only to the original consumer and only to products used in normal use and service. If this product is found to
be defective, the manufacturer’s only obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer’s
discretion, provided that the product has not been damaged through misuse, abuse, accident, modications, alterations, neglect, or mishandling.
WHAT IS NOT COVERED
This warranty shall not apply to any product that is found to have been improperly installed, set-up, or used in any way not in accordance with
the instructions supplied with the product. This warranty shall not apply to a failure of the product as a result of an accident. misuse, abuse,
negligence, alteration or faulty installation, or any failure not relating to faulty material or workmanship. The warranty shall not apply to the nish on
any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear.
The manufacturer does not warrant and specially disclaims any warranty, whether express or implied, of tness for a particular purpose, other than
the warranty contained herein. The manufacturer specically disclaims any liability and shall not be liable for any consequential or incidental loss
or damage, including but not limited to any labor / expense cost involved in the replacement or repair of said product.
Contact the Customer service team at 1-855-HD-HAMPTON or visit www.HamptonBay.com
12 VOLT TAP Cable Length
Total Fixture Wattage 0-50 feet 51-100 feet 101-150 feet
0-60 Watts 16 AWG 16 AWG 14 AWG
61-120 Watts 16 AWG 14 AWG 12 AWG
121-180 Watts 14 AWG 12 AWG NOT RECOMMENDED
181-240 Watts 14 AWG 12 AWG NOT RECOMMENDED
241-300 Watts 12 AWG NOT RECOMMENDED NOT RECOMMENDED
600W Transformer = (2x300 Watts) 12 AWG NOT RECOMMENDED NOT RECOMMENDED
900W Transformer = (3x300 Watts) 12 AWG NOT RECOMMENDED NOT RECOMMENDED
15 VOLT TAP Cable Length
Total Fixture Wattage 0-50 feet 51-100 feet 101-150 feet
0-60 Watts 16 AWG* 16 AWG 16 AWG
61-120 Watts 16 AWG* 16 AWG 12 AWG
121-180 Watts 14 AWG* 14 AWG 12 AWG
181-240 Watts 14 AWG* 14 AWG 12 AWG
241-300 Watts 12 AWG* 12 AWG NOT RECOMMENDED
600W Transformer = (2x300 Watts) 12 AWG* 12 AWG NOT RECOMMENDED
900W Transformer = (3x300 Watts) 12 AWG* 12 AWG NOT RECOMMENDED
* NOT RECOMMENDED FOR HALOGEN LANDSCAPE LIGHTS
NOTE: Most LED landscape xtures can operate with full illumination from 9V all the way to as little as 6V. It is possible to have extended length runs
with LED xtures that go beyond the specications shown on the charts above.