Specification
ProLED
®
Select T8 Linear
Hybrid
Specifications
Product Description
The ProLED Select T8 Linear Hybrid (Type A+B) lamps offers the most versatile installation solution for your linear
fluorescent T8 or T12 retrofit needs. Fully certified as a UL 1598C retrofit kit in single end or double end ballast bypass
scenarios (UL Type B) and UL listed for use with electronic T8 fluorescent ballasts (UL Type A), these lamps provides the
perfect, hassle free solution for whatever the project requires. When being used with an instant start, programmed start,
or emergency backup ballast, no fixture re-wiring is needed. If the ballast fails in the future, simply re-wire the fixture with
120-277V line voltage using either single end or double end wiring.
This CCT selectable hybrid comes in 2-foot, 3-foot, and 4-foot lengths, and offers users the ability to select between
3500K, 4000K, and 5000K kelvin temperatures by simply sliding the selector on the tube to the desired color.
LED Lamps
Page 1/2 Rev Date: 05/27/22
Halco Lighting Technologies 2940 Pacific Drive | Norcross, GA 30071 | Toll Free 800.677.3334 | Phone 770.242.3612 | Fax 800.880.0822 | halcolighting.com | Atlanta | Chicago |
Cleveland | Houston | Los Angeles | Phoenix © 2022 Halco Lighting Technologies, LLC. All rights reserved. Halco and ProLED are registered trademarks of Halco Lighting
Technologies. All sizes and specifications are subject to change
DATE: LOCATION:
TYPE: PROJECT:
CATALOG #:
• Maximum convenience for installation
• Reduce stocking needs
• UL listed & UL classified
• 116+ LPW efficacy
• IS, PS, EM ballast compatible
• 120-277V ballast bypass (single or double end)
• CCT selectable: 3500K/4000K/5000K
• 2FT, 3FT, and 4FT lengths available
DUO
Type A/B
THIS IS TEMPLATE FOR NEW
Construction
• High quality frosted pet coated glass construction
• Plastic endcaps
• 320 degree beam angle
• No mercury or UV emissions
• Instant startup
• Suitable for dry or damp locations
• Current leakage protection (UL 1993)
Installation
• Can be installed as either a Type B or Type A lamp
• As Type A, operates on electronic fluorescent
T8 instant start, programmed start, or
emergency ballasts
• As Type B, replaces T8 or T12 fluorescent lamps
when fixture is re-wired (single end or double
end wiring)
Performance
• Operates on electronic fluorescent T8 instant
start, programmed start, or emergency ballasts
• Operates on 120-277V
• 12.5W, 1,600 lumens
• 3500K/4000K/5000K
• 116+ LPW
• L70 >50,000 hrs
• 83 CRI
Certifications
• UL listed (for UL Type A installation)
• UL classified 1598C retrofit kit
(for UL Type B installation)
• FCC compliant
• NSF rated
• DLC 5.1
• Suitable for dry or damp locations