Mounting and Operating Instructions (Simple Programming) Art.No..: 732.29.125, published: 10/2003 Wall Terminal 2000 V.7 Art. No. Model Trans. Format Art. No. Model Trans. Format 917.01.101 917.01.104 Int., 1 Relay Int., 4 Relays TI-RFid TI-RFid 917.21.101 917.21.104 Int., 1 Relay Int.
Contents Components supplied………………………………………………………………….3 Area of use………..…………………………………………………………..………….3 Features………………………………………………………………………………..….3 Installation instructions………………………………………………………………..4 Start-up…………………………..……………………………………………….………11 Instructions for use………………………………………………………….…………12 Operation…………………………………………………………………………………13 RESET…………………………………………………………………………………….13 FAQs………………………………………………………………………………………14 Technical Data………………………………………………………………………..
Components Supplied • • • • Reader unit (1) Control unit (2) Installation frame (3) These instructions Area of Use The wall terminal is part of the Dialock electronic locking systems. It is an access-control system for outdoor and indoor use and can be used for a variety of purposes such as: • • Opening and closing doors by triggering electric door openers, motor locks, automatic doors etc. Triggering electrical equipment (e.g.
Installation instructions Safety Note: Before beginning installation, ensure that the power supply is switched off. The installation work should be done by a qualified electrician only, as complex wiring is required. Unsuitable tools may cause damage to the wall terminal. Please note that the wall terminal is intended only for switching electrical equipment with max. 1 A constant current and 2 A short-time current. Incorrect or incomplete installation may cause permanent damage to the system.
1. 2. 3. 4. 5. 6. 7. Control unit Reader unit Equipment being switched (door, barrier) Power supply for equipment being switched Distributor External CPU (e.g. PC) (optional) Power supply for control and reader units Model No.: DTS120250U/AC6-AMP-SZ Art.No.: 917.93.
Example: electrical connection of an electrical strike 1. Power supply Model No.: DTS120250U/AC6-AMP-SZ Art.No.: 917.93.005 2. Electrical strike 3.
The connection between the reader and the control units can be made using a standard 4-conductor cable. We recommend using a standard electrical cable J-Y (St) Y 2 x 2 x 0.8 with a maximum distance of 100 meters. When installing several wall readers, ensure that the distance between the reader units is at least 25 cm (fig. 7). If the distance is too small, the HF fields may overlap. This may cause the transponder media to not be reliably detected.
Control Unit Model No.: DTS120250U/AC6-AMP-SZ Art.No.: 917.93.
Mounting the reader unit - Screw the frame of the reader unit into the desired recessed socket - Remove the rear cover - Connect wires as shown in connection plan in table 1 page 7 - Push cable into cable comb - Replace cover and screw into place - Place the reader unit in the frame and allow it to click into position 9
- To disassemble, push a screwdriver into the slot and pry the unit out as shown. Mounting the control unit The control unit may be damaged by use of unsuitable tools. - - The distance between the control and reader units may be up to 100 meters. Mount the control unit on a standard rail (top-hat rail) in accordance with DIN EN 50022. Connect the wires as stated in table 2 page 8 If necessary, connect a recovery diode (100V) on the equipment being switched (door opener).
Start-up The wall terminal is supplied in the “simple programming mode” of operation. Only this mode is described in these instructions. Other operating modes are possible only after consultation with the Dialock sales office. Ensure that unauthorized persons do not misuse the user keys. Keep the programming ADD and DELETE keys in a safe place, as these are used for authorizing user keys.
Operating Instructions Assignment of access rights to user keys 1. Present the green programming ADD key in front of the operating panel. 2. The green LED display flashes. 3. Present the user key to be learned in front of the operating panel within 5 seconds. The green LED lights up to indicate that the locking right for the user key has been assigned. 4. Remove the user key. 5. Present the next user key to be learned in front of the operating panel within 5 seconds.
Operation 1. Present an authorized user key in front of the operating panel. 2. The green LED display lights up. The red LED display goes off. 3. The equipment being switched (e.g. door opener) is unlocked. If the LEDs do not switch from red to green: ð Present the user key closer to the reader. If the LEDs still do not switch from red to green: ð The user key has no right of access Reset General: The RESET button is located on the control unit beneath the housing cover between the two indicator LEDs.
If the RESET button is pressed for longer than 4 sec. A total RESET takes place. This resets all the configuration data (basic settings) and cancels all data (including user data). Release the RESET button when the red LED has stopped flashing. Single RESET (short RESET): If the RESET button is pressed for longer than 1 sec. But less than 4 sec. a single RESET takes place. This resets only the project code. Release the RESET button while the red LED is flashing.
Technical data Voltage supply: DC voltage Continuous current consumption Peak current consumption Number of relays Contact rating of delays 9-17 V < 150 mA 200-300 mA depending on number of relays 1 or 4 as required DC voltage max. 60 V AC voltage max. 125 V Switching current Max. 2 A (short period) Continuous current max. 1 A max. 30 W / max.
Notes: 16
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device my not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications made to this equipment not expressly approved by HAFELE America Co. or SPHINX Electronics GmbH & Co KG may void the FCC authorization to operate this equipment.