Re: Certification for Hafele. DT2000 Transmitter Model: DT2000 FCC ID: PW3108 USER'S MANUAL INFORMATION (PRELIMINARY) The User's Manual is in preparation. The following material will be contained in the manual: FCC ID: PW3108 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Mounting Instructions Door Terminal Basic European version
Contents Contents Area of use...................................................................................... 3 Technical information .................................................................... 3 Scope of delivery.............................................................................4 Mounting ......................................................................................... 6 Disassambly....................................................................................
Mounting Instructions Attention! • It is essential that you read the "Commissioning" section of these instructions before commissioning (allocation of keys). Area of use The Door Terminal Basic is an electronic door fitting used principally in the hotel sector. It is mounted on interior doors with mortise locks acc. to DIN 18 251 and can also easily be retrofitted on the door leaf.
Mounting Instructions Scope of delivery 2 5 9 10 8 6 2 4 3 8 7 10 3 1 1 Door Terminal Basic : 1 outer module (fixing plate with bracket and cover) 2 1 set of rosette fittings 3 2 door handles Small parts bag: 4 5 1 chipboard screw, 3 x 20 1 retaining ring 6 1 pin, 3 x 22 7 8 1 pin, 4 x 22 2 adhesive labels (to assist mounting) 9 Fastening parts: 1 square Spindle 10 4 countersunk screws M4 The length of the fastening parts depend on the thickness of the door leaf.
Mounting Instructions Accessories (not included in the scope of delivery): User and Programming Key-sticks 2 lithium batteries 1 release lever 1 pair of retaining ring pliers 28
Mounting Instructions Spare parts (not included in the scope of delivery): 1 3 2 4 1 1 cover (available in a variety of colors) 2 1 bag of fastening parts (square spindle and countersunk screws, M4) 3 1 small parts bag 4 1 fixing plate 29
Mounting Instructions Mounting Requirements: • DIN mortise lock Depending on the design of the fixing plate, it is also possible to use mortise locks on the Door Terminal Basic that deviate from the DIN norm (e.g. for Austria).
Mounting Instructions Adapting the Door Terminal Basic for right-facing door handles The Door Terminal Basic is adapted for left- or right-facing door handles using the pins on the back of the fixing plate (with the bracket). 1. Place the door handle on the bracket in such a way that the direction of door handle movement is appropriate for its use. 2. Turn the external square with the door handle at its upper limit (zero position) and hold it.
Mounting Instructions R L R80 L80 R45 L45 3. Using a hammer, lightly tap a 3 x 22 pin into the drilled hole labelled "R" on the back of the fixing plate. The spring of the door handle is under pressure. 4. Insert a 4 x 22 pin in the drilled hole labelled "R45°" on the back of the fixing plate for the door handle limit. If the door handle angle of rotation is to be greater than 45°: Ö Insert a 4 x 22 pin in the drilled hole labelled "R80°" on the back of the fixing plate. 5.
Mounting Instructions 6. Remove the door handle from the external square spindle. The Door Terminal Basic is adapted for a right-facing door handle. Proceed as follows if the pins have been inserted in the wrong side: Ö Remove the 8 screws in the fixing plate. Ö Remove the fixing plate from the bracket. Ö Pull the pins out of the bracket, using pliers if necessary. Ö Place the fixing plate on the bracket. Ö Tighten the screws. Ö Repeat the adaptation process for the correct hole location.
Mounting Instructions Adapting the Door Terminal Basic for left-facing door handles The Door Terminal Basic is adapted for left- or right-facing door handles using the pins on the back of the fixing plate (with the bracket). 1. Place the door handle on the bracket in such a way that the direction of door handle movement is appropriate for its use. 2. Turn the external square with the door handle at its upper limit (zero position) and hold it.
Mounting Instructions R L R80 L80 R45 L45 3. Using a hammer, lightly tap a 3 x 22 pin into the drilled hole labelled "L" on the back of the fixing plate. The spring of the door handle is under pressure. 4. Insert a 4 x 22 pin in the drilled hole labelled "L45°" on the back of the fixing plate for the door handle limit. If the door handle angle of rotation is to be greater than 45°: Ö Insert a 4 x 22 pin in the drilled hole labelled "L80°" on the back of the fixing plate. 5.
Mounting Instructions 6. Remove the door handle from the external square spindle. The Door Terminal Basic is adapted for a left-facing door handle. Proceed as follows if the pins have been inserted in the wrong side: Ö Remove the 8 screws in the fixing plate. Ö Remove the fixing plate from the bracket. Ö Pull the pins out of the bracket, using pliers if necessary. Ö Place the fixing plate on the bracket. Ö Tighten the screws. Ö Repeat the adaptation process for correct hole location.
Mounting Instructions Mounting the square spindle 1. Insert the square spindle in the inner coupling component in such a way that the pins are located in the cavities of the coupling component. 2. Using the retaining ring pliers, insert the retaining ring in the slot of the inner coupling component. In the process, ensure that the opening of the retaining ring is not lying over any of the upper square spindle pins. This completes the square spindle mounting process.
Mounting Instructions Mounting the Door Terminal Basic The following steps are necessary for mounting the Door Terminal Basic : • drilling holes for the rosette fittings and guiding pins • attaching the Door Terminal Basic • attaching the rosette fittings • setting up the Door Terminal Basic for operation Mounting on wooden doors is described below. Condensation forming on cold components can damage the Door Terminal Basic. Ö Ensure that all components are at room temperature.
Mounting Instructions 3. Drill holes at least 6 mm deep in the outer side of the door with drill bit Ø = 8 mm. 4. Drill holes in the inner side of the door with drill bits Ø = 8 mm or Ø = 7 mm (depending on the rosettes used). Attaching the Door Terminal Basic a a Slot of the square spindle 1.
Mounting Instructions 3. Place the bolting elements of the rosette fittings on the inner door leaf in such a way that the screw guides are located in the drilled holes. 4. To connect the fixing plate (and bracket) to the bolting elements: attach the bolting elements firmly with two screws each. 5. To attach the fixing plate to the door: tighten 3 x 20 chipboard screws in one of the three upper drilled holes of the fixing plate. The Door Terminal Basic has been attached.
Mounting Instructions Attaching the rosette fittings 1. Place the ornamental plates of the rosette fittings on the bolting elements in such a way that they snap into place. 2. Place the door handle on the square spindle in such a way that the set screws point in the direction of the strike. 3. Tighten the set screws. 4. Install the profile cyclinder, if available. The rosette fittings have been attached.
Mounting Instructions Setting up the Door Terminal Basic for operation 1. Insert two lithium batteries type ½ AA 3V in the battery compartment. Use correct polarity! (See also "Changing the batteries") 2. Place the lower part of the cover on the bracket in such a way that the cover guides are located in the ledges of the bracket. 3. Press the upper part of the cover back on the bracket, until it audibly snaps into place. Take care not to damage the sensitive plug-in connections. 4.
Mounting Instructions Disassambly Tools required: • retaining ring pliers • screwdriver • release lever • 3 mm Allen wrench 1. Undo the set screws. 2. Remove the door handles. 3. Use the release lever to remove the cover from the bracket. 4. Remove the batteries from battery compartment. 5. Undo the screws in the upper fixing plate. 6. Remove the ornamental plates of the rosette fittings with a screwdriver. 7. Undo the screws of the bolting elements. 8.
Mounting Instructions Commissioning Assigning Programming ADD and DELETE Key-sticks In the simple operating mode the Programming ADD and DELETE Key-sticks must be assigned during commissioning. Attention! Ö In order to prevent abuse of the electronic keys by unauthorised persons: keep Programming ADD and DELETE Key-sticks in a safe place. 1. Get the green Programming ADD Key-stick and the red DELETE Key-stick ready. 2. Switch on the Door Terminal Basic by pressing the white button on the display.
Mounting Instructions Brief operating inctructions Allocating access rights 1. Switch on Door Terminal Basic : press the white button on the display. The red LED lights up. The Door Terminal Basic is switched on. 2. Hold the green Programming ADD Key-stick in front of the Door Terminal Basic. The green LED blinks. 3. Present the user key to be learned in front of the Door Terminal Basic within 5 seconds. The green LED lights up solid in confirmation. Access rights have been granted to the learned user key.
Mounting Instructions Withdrawing access rights from all user keys If a user key is lost and should no longer retain its access rights, the access rights of all user keys must be withdrawn at the Door Terminal. After this, all the keys that remain and are to have access rights must be re-authorized/learned again. 1. Hold the red Programming DELETE Key-stick in front of the display of the Door Terminal Basic. The red LED blinks. 2.
Mounting Instructions Operation Opening the Door Terminal Basic 1. Switch on the Door Terminal Basic by pressing the white button on the display. The red LED lights up. The Door Terminal Basic is switched on though the door handle is still uncoupled. 2. Hold an authorized user key a few centimetres (1-3) from the Door Terminal Basic . The green LED lights up and the red LED goes out. The coupling of the door handle engages and the door can now be opened.
Mounting Instructions Replacement of batteries When the batteries are weak, the red and green LEDs blink alternately after the Door Terminal Basic has been switched on. If the batteries are empty, the door with the Door Terminal Basic can no longer be locked. Smooth operation of the Door Terminal Basic is only guaranteed if weak batteries are replaced immediately. We recommend that the batteries are changed at least every two years, to prevent any possible damage being caused by leakage of the batteries.
Mounting Instructions 2. Remove the door handle from the external square. 3. Press the upper part of the cover against the door leaf to remove the load from the magnets of the bracket. 4. Place the release lever on the cover from above in such a way that the back edge of the tool is engaged between the door leaf and cover and the magnets of the release lever are located above the magnets of the bracket. 5. Press the upper part of the release lever in the direction of the door leaf.
Mounting Instructions 10. Press the upper part of the cover back on the bracket, until it audibly snaps into place. Take care not to damage the sensitive plug-in connections.
Mounting Instructions 11. Place the door handles on the external square in such a way that the set screw points in the direction of the strike. 12. Tighten the set screw. The batteries have been changed. The Door Terminal Basic is ready for operation again. Emergency opening via the profile cylinder An emergency opening of the Door Terminal Basic can be carried out with a key via the profile cyclinder. 1. Loosen and remove the door handles (see 'Changing the batteries', Steps 1-2). 2.
Legal Notice Any reproduction of these Mounting Instructions, or extracts of it, or copying of the illustrations and drawings, or copying of the design is forbidden. No liability whatsoever is accepted for any printing errors or mistakes that may have taken place in the production of these Mounting Instructions. Delivery terms and technical details are liable to change without notice. Status 11.01 Copyright Sphinx Electronics GmbH & Co KG Tullastr.