Mounting instructions Wall Terminal
Mounting instructions Technical information All wall terminals are supplied in the basic method of operation. With this method of operation, electronic keys are given access authorisations directly at the wall terminal with a special programming key stick (green). Up to 100 electronic keys can be allocated per wall terminal. With a clearing key stick (red), the access authorisations of an authorised electronic key can be withdrawn directly at the wall terminal.
Mounting instructions Range of application Wall terminals control electric door openers and motor locks for: l external or internal doors or: l automatic roller shutters l barriers appliances and installations, such as goods dispensers or sun beds can also be monitored via wall terminals.
Mounting instructions Installation The following steps are necessary for the installation: l install the reader module l install the control electronics module l electrical installation 2 1 10 3 9 8 7 6 1 2 3 4 5 6 7 8 9 10 5 4 flat band cable (round, shielded) reader module element to be switched (appliance) power supply for element to be switched (appliance) distributor control electronics module power supply for control electronics module conductor interface cable (optional) online-adapter (optio
Mounting instructions Install the reader module Preparations: l drill a hole into the wall for the connecting cable between the reader module and the control electronics module. Lay a protective pipe with an internal diameter of at least 12 mm or a cable channel. l flush fitted installation: install a flush fitted container with a diameter of 70 mm and a minimum depth of 60 mm. l surface installation: drill a 25 mm diameter hole and minimum 48 mm depth for the PG-9-screw fixing. 1 1 2 2 3 min.
Mounting instructions 1 2 3 4 spacer plate reader module 10-mm-hole front foil 3. For installation on brick work: Ø drill holes for 6 mm dowels into the wall to fix the reader module. Ø fix the reader module with 4 Hospa screws, 4x50 mm. Make sure, that the 10 mm hole is at the bottom and that the screws do not protrude over the countersinkings. 4. For installation on metal: Ø drill four holes for an M4 thread. Ø cut the thread Ø fix the reader module with four countersunk screws.
Mounting instructions Ø guide the free end of the cable through the hole to the control electronics module. Ø cut the cable to length. Ø re-fit the PG-9-screw fixing to the cable. Ø guide the flat band cable through the aperture in the spare plug, such that the arrow on the plug is on the same side as the red marking of the flat band cable (polarity!) Ø squeeze the spare plug shut with water pump pliers or with special squeezing pliers. 6. Apply the front foil onto the reader module.
Mounting instructions Install the control electronics module Conditions: l cables and power supply for all appliances to be connected have been laid l for flush fitted installation: a sufficiently large drilling has been prepared 1 2 1 2 3 3 5 4 4 Flush fitted installation (left) and surface installation (right) of the control electronics module 1 2 3 4 5 protective pipe (internal diameter min.
Mounting instructions Electrical installation 8 7 S-Input1 Input2 Input1 TxData RxData GND RTS CTS 3 2 + NO NC COM 1 NO NC COM 4 NO NC COM 5 6 Occupancy schedule of the control electronics module 1 2 3 4 5 6 7 8 22 Plate of control electronics module TTL-entrances, to be approached via a switch relay 3 (optional) relay 2 (optional) relay 1 flat band cable connection to the reader module (pin bar) supply voltage serial RS-232-interface to the PC or online adapter engl.
Mounting instructions 1 2 5 4 3 6 1 2 5 4 3 Switch example: joint (top) and separate (bottom) power supply for the consuming device and the terminal 1 2 3 4 5 6 transformer (adapted to the voltage and output requirements of the element to be switched) element to be switched (appliance) relay 1 connection for the reader module plate of control electronics module transformer (adapted to the voltage and output requirements of the element to be switched) engl.
Mounting instructions Danger of death through an electric shock! ØMake sure, that the electrical installation is carried out by qualified personnel. Destruction of the relay contacts when operating the door opener with direct current! ØUse a free running diode. 1. turn off the fuses of all consuming devices to be connected and the power supply for the wall terminal! 2. make sure, all cables are voltage-free. 3.
Mounting instructions The plate is destroyed, if inappropriate tools are used! ØConnect the cables of the appliances to be connected only with the enclosed feeder implement. 1 2 1 2 feeder implement contact clamp 9. open the contact clamps with the feeder implement. 10. slide the cable into the contact apertures. 11. remove the feeder implement. 12. insert the cable of the sensor head into the pin bar. 13. fix the casing lid onto the casing with the enclosed plastic screws. 14.
Mounting instructions Initiation for basic method of operation Allocate the programming and deletion key-stick In the basic method of operation, the programming and deletion keysticks are allocated during the initiation. This step is only possible straight after the installation of the supply voltage for the wall-terminal.
Mounting instructions Brief operating instructions for basic method of operation Allocate access authorisations 1. Place the green programming key-stick in front of the reader module. The green indicator (LED) flashes. 2. Place the key to be introduced in front of the reader module within 5 seconds. The green indicator (LED) flashes briefly. The locking authorisation for the electronic key to be introduced has been allocated. 3. Remove the introduced key.
Mounting instructions How to operate the Wall Terminal Ø Place the electronic key with locking authorisation in front of the reader module at a distance of a few centimetres. The green indicator (LED) lights up, the red indicator (LED) switches off. The element to be switched is activated, i. e. the door opener is unlocked. If the LEDs do not switch from red to green: Ø Place the electronic key closer to the terminal.
Mounting instructions 732.29.101 The reprint of the mounting instructions, even extracts, or copying of the illustrations and drawings as well as copying of the layout are prohibited. No liability is accepted for printing errors or errors occurred during the creation of the mounting instructions. We reserve the right for technical changes and changes of availability. Status 06.