User Manual Hand Tremor Data Collector Version: TC200-EN-V3.
DEFINITIONS WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in invalid data collecting ,damage to the equipment or invalid operation. NOTICE: Information necessary to be known before using the equipment.
1 INTENDED USE The hand tremor data collector is used to collect hand tremor data of user with Parkinson's Disease, Parkinson’s Syndrome, Essential Tremor, or other physical disabilities. It can also be used as an assistive equipment to eat.
2 SAFETY INFORMATION WARNING 1 Do not place or store the equipment near fire or heat articles. 2 Do not use a damaged charging cable or socket. 3 Do not use the equipment if a pacemaker or electrical stimulation equipment is adopted. 4 Users allergic to medical rubber are not commended to use this equipment. 5 Do not plug or unplug the charging cable when hands are wet. 6 Do not make self-diagnose based on data collected by the equipment.
3 KNOW YOUR UNIT The equipment can collect tremor data of user by built-in sensors and transfer the data via WIFI. It can also detect and offset shaking of hand to help user eat smoothly.
Handle Figure 2 Handle Side View Item Description 1 Connecting point to attachments 2 Front part of handle 3 Distance sensor 4 Soft sleeve 5 Twist button 6 Rear part of handle Table 1 Handle Side View Description Figure 3 Handle Rear View Item Description 1 Power button Short press: Turn on or off the equipment Long press for 5 seconds: Enter WiFi configuration mode 2 Indicating light to identify different status 3 Fixing screw 4 Charging cable jack 5 Connecting dock for hand str
Attachment Figure 4 Spoon Attachment -8-
4 SYMBOLS USED General warning sign General caution sign Notice sign Refer to user manual.
5 SPECIFICATIONS Approx. 233 (L) * 52.5 (W) * 31.5 (H) (mm) Dimensions Total Weight ≈ 155 g Spoon Weight ≈ 6.7 g Fork Weight ≈ 5.4 g Measurement Range Frequency: 3 Hz to 12 Hz Amplitude: 6 mm to 100 mm Resolution Frequency: 0.
6 INDICATING LIGHT DESCRIPTION Color Status Breathing in green Standby Green Fully charged Breathing in blue Collecting data Flashing in blue WiFi connected or data transferring Breathing in red Low battery Red Charging Flashing in yellow Under WiFi configuration Yellow WiFi not connected NOTICE 1 If the indicating light alternates in red and yellow, the equipment is charging and not connected to WiFi.
7 DOWNLOAD MOBILE APPLICATION Please search for “GYENNO SPOON” in the appropriate mobile application store, download and install it. You can also visit www.gyenno.com/spoon2 for downloading the mobile application “GYENNO SPOON”. Open the app on your smartphone and follow the WiFi configuration instructions.
8 BEFORE USING Attachments Installation The attachments will adhere to the handle by magnetic force when the attachments are placed near the handle as shown below. Figure 5 Installing Attachment How to Hold the Equipment Make sure the attachment is firmly connected to the handle before using. It is recommended to hold the equipment as shown below. For users with severe tremor or stiff, please put on the hand strap before using to avoid dropping the equipment.
Power On and Off Short press the power button to turn on or off the equipment. When the equipment is standby, the indicating light breaths in green. NOTICE The equipment will automatically turn off if it had not been working for 5 minutes.
9 TAKING A MEASUREMENT When the equipment is on and once it detects tremor, data collecting will start. The indicating light breaths in blue. Figure 7 Taking a Measurement The data collecting process takes a few minutes (measurement period), when it is completed, the indicating light breaths in green. Each measurement period the equipment exports a measurement result including frequency and amplitude. NOTICE 1 Reboot the equipment before taking the next measurement.
2 The measurement is terminated.
10 ASSIST TO EAT Shaking Offset Once the equipment detects tremor, the internal motors actively offset the shaking to keep stable. Figure 9 Vertical Shaking Offset Figure 10 Horizontal Shaking Offset Twist Function The equipment offers a twist function to help the user eat noodles, spaghetti, pasta, etc. Install the fork before using the twist function, press and hold the button to start twisting, loose the button after twisting the noodles, the fork will then reset to horizontal.
11 AFTER USING Attachments Uninstallation Please power off and uninstall the attachments after using. The handle should be placed horizontally. It is suggested that both the handle and attachments should be cleaned each time after using. Charging If the indicating light breaths in red, the equipment can still work for approximately 10 minutes. In order to protect the mechanic parts, please charge the equipment as soon as possible. To start charging, plug in the charging cable and connect to power.
12 CLEANING AND DISINFECTION Attachments NOTICE The attachments should be cleaned before the first use. Please uninstall the attachments from the handle before cleaning. The attachments are suggested to wash with utensil detergent and water, they can also be cleaned in the dishwasher. Wipe the attachments with dry cloth. Do not submerge the attachments into detergent contains corrosive ingredient. If low-level disinfection is required, use alcohol solution (ethanol (75%), isopropyl (70%), e.g.
13 MAINTENANCE 1. The attachment should be uninstalled from the handle before cleaning. Use a small portion of utensil detergent and water to wash. 2. The attachment should not be submerged into detergent contains corrosive ingredient. 3. Any part of the handle is not waterproof, do not splash water on the handle or submerge it into water. Wipe and clean the handle with antibacterial tissue or cotton cloth soaked with alcohol. 4.
14 TROUBLESHOOTING Problems Causes and solutions The equipment is not registered in “GYENNO SPOON” . Please register the equipment follow the instructions in “GYENNO SPOON” . No data shown The equipment is not connected to the WiFi. Please configure the WiFi follow the instructions in “GYENNO SPOON”.
15 PRECAUTIONS 1. 2. 3. 4. 5. It is suggested to use this equipment independently at the first time to avoid worse tremor caused by the anxiety and nervous since the users may have difficulties on daily eating and being taken care of. It is suggested to proactively adjust holding gestures and ways of sending food to mouth at the beginning of adopting the equipment. The best way of using the equipment will come after some time.
16 CONTRAINDICATIONS Do not use the equipment if a pacemaker or electrical stimulation equipment is adopted. Users allergic to medical rubber are not commended to use this equipment.
17 EMC INFORMATION Guidance and manufacture’s declaration – electromagnetic emission TC200 is intended for use in the electromagnetic environment specified below. The customer or the user of TC200 should assure that they are used in such an environment.
Guidance and manufacture’s declaration – electromagnetic immunity TC200 is intended for use in the electromagnetic environment specified below. The customer or the user of TC200 should assure that they are used in such an environment.
Guidance and manufacture’s declaration – electromagnetic immunity TC200 is intended for use in the electromagnetic environment specified below. The customer or the user of TC200 should assure that they are used in such an environment. Immunity test Conducted RF IEC/EN 61000-4-6 Radiated RF IEC/EN 61000-4-3 IEC/EN 60601 test level Compliance level 3 Vrms 150 kHz to 80 MHz 6 Vrms in ISM bands between 0,15 MHz and 80 MHz N/A 3 V/m 80 MHz to 2.7 GHz 3 V/m 80 MHz to 2.
Recommended separation distances between portable and mobile RF communications device and TC200 TC200 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of TC200 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications device (transmitters) and TC200 as recommended below, according to the maximum output power of the communications device.
Test specifications for enclosure port immunity to RF wireless communications device Test frequency (MHz) Band a) (MHz) Service a) Modulation b) Maximum power (W) Distance (m) Test frequency (MHz) 385 380-390 TETRA 400 Pulse modulation b) 18 Hz 1,8 0,3 27 450 430-470 GMRS 460, FRS 460 FM c) ± 5 kHz deviation 2 0,3 28 704-787 LTE Band 13, 17 Pulse modulation b) 217 Hz 0,2 0,3 9 800-960 GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 Pulse modulation b) 18 Hz 2 0,3 28 1
18 REGULATORY INFORMATION FCC ID: 2ACGF-TC200 IC: 24095-TC200 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
19 LIMITED WARRANTY The handle of the equipment is warranted to be free from defects within 12 months starting from date of purchase. The attachments (spoon and fork) and accessories (charging cable) are free from defects within 6 months starting from date of purchase. Any part of the equipment, including attachments and accessories, is not allowed to be repaired by unspecified maintenance. One of the following occurs is not eligible for warranty claim: ● Damage caused by dismounting on customer’s own.
20 DISPOSAL GYENNO has always been committed to earth care, we also encourage our users to make contribution by executing proper disposal: ● Packaging materials should be handed over recycling companies for possibility of re-use. ● Comply with relevant laws and regulations when disposing wasted parts and components. ● The equipment should be disposed as electronic waste.
21 COMPLIED STANDARDS EN ISO 14971:2019(ISO 14971:2019 IDT) EN ISO 15223-1:2016(ISO 15223-1:2016 IDT) EN ISO 780:2015(ISO 780:2015 IDT) EN 1041:2008+A1:2013 EN 60601-1:2006+A11:2011+A1:2013+A12:2014(IEC 60601-1:2005+A1:2012 IDT) EN 60601-1-11:2015(IEC 60601-1-11:2015 IDT) EN 60601-1-2:2015(IEC 60601-1-2:2014 IDT) - 33 -
MANUFACTURER INFORMATION Manufacturer Address GYENNO Technologies CO., LTD. A805 A806, Shenzhen Institute of Industry-University-Research of HUST, No.9 Yuexing 3rd Road, Science Park, Nanshan District, Shenzhen, 518000, P.R.China. Tel. 0086-755-86724035 Email service@gyenno.com Website www.gyenno.