User Manual Language: English Version: 1.
Table of Contents 1 Indications for Use.......................................................................................................... 3 1.1 Symbols .................................................................................................................. 3 1.2 Safety ...................................................................................................................... 4 1.3 Warning......................................................................................
1 Indications for Use It is essential to read the operating instructions carefully and completely before using the first time the equipment and software. They contain important information on safety, installation and use. Keep these instructions in a safe place. 1.1 Symbols Warning of dangerous situations that can cause injury and damage to the devices. Warning The ZONESCAN Correlating Noise Logger contains a very powerful magnet.
1.2 Safety The operating and maintenance personnel must read the instructions carefully before using the equipment. Knowing all the information contained therein - in particular the warning and safety instructions - is needed to safely operate the equipment, and to protect yourself and others against possible dangers. Ignoring the warning, safety and operating instructions can result in injury, damage, or a considerable shortening of the equipment life time.
2 Delivery Contents The EASYSCAN System contains the following components: 1. Smartphone or tablet computer with Android OS (optional) 2. Ground Plate and 3 Rods a. Pointed rod b. Extension rod c. Handle rod 3. EASYSCAN Link including USB battery charge cable 4. EASYSCAN Red and Blue Correlating Sensors 5. Robust carrying case 6. Sensor Clips 7. Around-the-Ear Headphones (optional) 8.
3 Installation EASYSCAN Software This guide helps with installing and running the EASYSCAN software for Android OS. For help with getting started please refer to chapters 4, 10, or the enclosed Quick Start Guide. 3.1 Features EASYSCAN currently has the following features: Programming of EASYSCAN Correlating Sensors via Link Show Sensors in map Listening Feature Free offline maps available for download View saved correlations and listenings in Histroical data section 3.
A one time setup of the link and sensors are required. On the intial screen enter your Company Name and Link Serial Number which can be found in the red panel of the link. The next screen choose “Open Bluetooth Settings” , Switch on the Link and SCAN for the EASYSCAN ******* Link and pair (no PIN required). Use the back arrow to return to EASYSCAN then select “Pair Device”.
4 EASYSCAN Link On/off: The link can be switched on and off by using the push-button on the side. The LED will blink every 2 seconds when the link is on. Charge: Connect the link with the USB cable to a USB 2.0 or higher port to charge. The LED will blink fast to indicate the charging process. Battery status: The status can be seen in the top icon bar on your android device. The link needs to be connected to your device for this.
Switch the Link on and tap Synchronise Deploy the Red Sensor first using the tablet to plot the sensor position. If the GPS position is not accurate enough, you can move the map with your finger (zooming in increases position accuracy). Then tap the green arrow to confirm. Repeat for the Blue sensor and the correlation starts. A timer counts down until the measurement is completed The EASYSCAN App will instruct the user to collect the Sensors. Once collected tap next to download the data.
below. Tap the headphone symbol if you wish to pin point the leak, or the chart symbol to filter the correlation manually. The Correlation Filter screen on the right hand-side shows the correlation chart on the top with the leak position as a peak over the length of the pipe. With the buttons in the middle you can switch automatic or manual filtering on/off. The bottom chart shows the similarity of the acoustic signal between the red and blue sensors over the frequency.
6 Listening Hardware: For a description of how to prepare your hardware for the listening operation, please refer to section 9 of this manual. In your App: Tap “Listening” The EASYSCAN system is a listening stick or a ground microphone. Simply tap on “Listening” on the main screen then attach a sensor to the ground plate using the magnet. Then choose the appropriate rod configuration to create the microphone required. 6.
To pin point the leak using the noise level feature place mic on the ground surface (above the pipe) and press play, listen for 5 seconds then press stop, move to the next spot above the pipe and press play, listen for 5 seconds and press stop. Repeat the process until the highest number has been found. The highest noise level and the highest pitch is likely to be the leak. 6.
Configure the rods to create a listening stick then either tab the middle symbol when listening through soft ground or the lower symbol if listening on fittings such as valves, hydrants or meter services. Repeat the process as described above. 6.3 Creating a Leak Event You can save a listening permanently (and later load in from “Browse Data”). For this, you create a Leak Event tapping the “+” button at the bottom right corner of the screen.
8.1 Download Maps By default, EASYSCAN uses online Open Street Maps. However, this requires network access. In addition, the map server can be slow which causes grey tiles in the map. To download an offline map, you need a fast internet connection. Then choose the map required in the list of countries as shown below.
I 19
9 Help The help button is on the bottom left of the main screen. 9.1 Send Problem Report If the user has any issues with the EASYSCAN System then simply use the “Send Problem Report” option to email support with the problem. Fill out the steps within the email which lead up to the problem, fault or crash, then hit Send. 9.2 Sharing measurements EASYSCAN has the ability to share measurements with Gutermann Support who will be able to advise on a problem. Tap the Send Database and send via email.
10 Detailed Instructions of Kit Setup For the Correlation Operation: Connect the clip to the sensor: 1. Push clip vertically over the top of the sensor handle 2. Push the clip down until you hear a second click 3. Pull the clip back up until the sensor handle is blocked in the clip hooks (and you hear a click) Release the sensor from the clip: 1. Push the clip down to release the sensor handle from the hooks 2. Turn the clip carefully sideways on the handle 3.
11 Technical Data EASYSCAN SENSOR Models numbers: GESA401 (red sensor EU) GESB401 (blue sensor EU) GESA501 (red sensor North America) GESB501 (blue sensor North America) Technical Data: Casing: Rubber shrouded high-quality Aluminum casing Ingress Protection: IP68, submersible up to 2 meters Temperature Range: -30ºC to +70ºC Battery Life: Depending on user-specific usage, but optimized in firmware Dimensions: 174 mm x Ø 51 mm (height x diameter) Weight: 375 grams Data Transmission: P
13 Imprint Gutermann Technology GmbH Gottlieb-Daimler-Str. 10 88214 Ravensburg, Germany Subject to changes Tel: +49 751 3590 1682 Fax: +49 751 3590 1699 www.gutermann-water.com info@gutermann-water.com 14 Conformity This device complies with part 15 of the FCC Rules and with Industry Canada's licenceexempt RSSs.