Catalogue Preface------------------------------------------------------------------------- 3 1 Production introduction---------------------------------------------------- 3 2 Product installation and function description--------------------------- 4 3 Operation instructions-----------------------------------------------------11 4 Notes-------------------------------------------------------------------------19 5.
Preface Thank you for purchasing the imaging plate scanner produced by Guilin Woodpecker Medical Instrument Co., Ltd. Woodpecker is a high-tech enterprise researching, developing, producing and selling dental products. It owns a sound quality control system. To ensure that you use the equipment correctly and safely, please read the full text of the instruction manual carefully before use. 1 Production introduction 1.
mixture with air, oxygen, or nitrous oxide: Equipment cannot be used in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous oxide. 1.8 Primary technical parameters 1.8.1 Power adapter input: 100-240V 50/60Hz,1.5A 1.8.2 Power adapter output: DC 30V 3A 1.8.3 IP imaging plate model: 0; 1; 2; 3 1.8.4 Threshold contrast: 4 holes of 1.0 mm, 1.5 mm, 2.0 mm and 2.5 mm can all be distinguished. 1.8.5 Image uniformity: <2% 1.8.
IP imaging plate inlet Touch screen Power switch USB interface Power supply socket IP imaging plate tray Figure 1 Schematic diagram of imaging plate scanner (Left is the back of the device and right is the front of the device) 2.2 Accessories installation 2.2.1 Installation area Take out all the parts from the packing box. Be careful not to drop or damage the equipment. 2.2.
plate scanner is in use. The computer system must also meet the following configuration requirements: Windows®: Recommended configuration Operating system Windows® 7 , Windows® 8 , Windows® 10 . Processor Intel® Core 2 Memory 2 GB or above Hard disk 320 GB or above USB port 4 high-speed USB 2.
Figure 4 d) Read the license agreement. The user chooses whether to agree to this agreement, if the user agrees, click the "Next" button, do not agree, cancel the installation, as shown in Figure 5: Figure 5 e) Select components.
Figure 7 g) Click the “Install” button to start the installation, as shown in Figure 8: Figure 8 h) After the “Install” button is clicked, the program starts to install.
Figure 10 2.3.
b) Click“WIFI” c) Click"Open WIFI" d) Click the WIFI to connect e) Open the software, click the Acquisition button, and select the I-SCAN device type. After connecting the device, the IP address will be displayed below the device type. Click open, and the device will enter the acquisition state, and images can be collected.
3 Operation instructions 3.1 Preparation before X-ray photographing 3.1.1 Start the image management software on the image workstation and create a new patient file or open an existing patient file. 3.1.2 Take out the IP imaging plate of the required size from the storage box. Note: Natural X-rays and/or X-rays scattered by the X-ray generator may cause the imaging phosphor to be exposed before normal use. Warning: There is a risk of cross infection.
sprayed with disinfectant. ② Wear protective gloves when placing the disposable protective bag of IP imaging plate into the patient’s mouth. 3.2.1 Place the sealed protective bag with the IP imaging plate in the patient’s mouth, parallel to the longitudinal axis of the teeth. The back (black side) of the protective bag must face the X-ray generator. 3.2.2 Select the appropriate exposure value on the dental X-ray generator. 3.2.3 Move the dental X-ray generator towards the patient’s mouth.
3.4 Erase IP imaging plate After reading, the image data of IP imaging plate will be automatically erased before the plate falls into the tray of imaging plate scanner. However, if the IP imaging plate is used for the first time, or it has been stored for more than 24 hours, or it has been stored in a dark room, or the image data of imaging plate scanner is not erased, it is necessary to conduct erasing. 3.5 Software operation instructions 3.5.
Figure 13 3.5.2 Patient module Click the “Patient” button to enter the patient module. a) Add, modify and delete patients Click the “Add Patient” button to enter the information, click “OK” and a patient can be added. If you need to modify the patient information, click the “Modify Patient” button to modify the patient information, click “OK” and the modification can be successful. If you need to delete a patient, click the “Delete Patient” button and click “OK”.
Figure 15 c) Image preview Click the “Preview” button to view acquired images. Select an image, rightclick and select “Export” to export the image to the local. Select “Information” to view the information of the image. Select “Delete” to delete the image. Double-click the image to enter the diagnosis interface. As is shown in Figure 16: Figure 16 3.5.3 Diagnostic module Click the “Diagnosis” button to enter the diagnosis module. Click the image on the left to select an image to be processed.
Temporary State” button to save the image quality at this time. Select the temporary state in the drop-down box to reproduce the image. There are delete, export, and image information functions above the processed image. These functions are similar to the corresponding functions of the patient module. When multiple images are selected for processing, click the “Clear” button to close them all. Move the mouse wheel up and down to zoom in and out of the image.
Figure 18 3.5.5 Setting module Click the “Setting” button to enter the setting module. a) Basic setting Click the “Basic Setting” button to enter the basic setting page. Click the “Sign Out” button to return to the login interface. Click the language dropdown box to select the software language. Click the tooth profile drop-down box and select the tooth profile number.
Figure 20 c) Image processing Click the “Image Processing” button to enter the image processing interface. Select the HD checkbox, select “HD”, and the acquired image will be initialized and HD processed automatically. Select “Ultra HD”, and the acquired image will be initialized and Ultra HD processed automatically. As is shown in Figure 21: Figure 21 d) IP setting Click the “IP Setting” button to enter the IP setting interface. Enter the IP address and port number.
clients connected to the server will receive a reminder of 10s countdown to upgrade. After 10 seconds, the software will automatically close and then start to upgrade. Click “No” and the software will not be upgraded temporarily. 4 Notes 4.1 The imaging plate scanner shall never be used in the presence of flammable anesthetic gas, pure oxygen or nitrogen oxide to avoid any risk of explosion. 4.2 The imaging plate scanner is a Class I laser product and turns to Class 3B after the cover is removed.
4.11 When the image quality is affected by excessive use or artificial damage of IP imaging plate, the device needs to be replaced in time. 5. Troubleshooting Fault Possible cause Solution 1. Reinstall the WIFI The software interface WIFI driver is not driver shows the connection installed. 2. Contact the local timeout. distributor 1. Reinstall the entrance The environment light is Environment light cover plate too strong to operate the intensity alarms 2. Avoid direct strong light equipment.
6.3 Cleaning, disinfection and sterilization of storage box of IP imaging plate a) The storage box of IP imaging plate can be cleaned with a non-abrasive cloth dipped in a detergent. The recommended detergents are cold water, warm water, soapy water, and medical ethanol. Make sure the parts are completely dried before use. b) The storage box of IP imaging plate can be disinfected with a wipe dipped in a disinfectant. Aldehyde-free disinfectant is recommended.
8 Environment protection This device cannot be disposed of as household waste. Therefore, this equipment should be placed in a special recycling place for waste electronic medical and electrical equipment. For more detailed information about equipment disposal and recycling, please contact the dental equipment dealer. 9 After-sales service Since the date of sale, if the device fails to work normally due to quality problems, our company will be responsible for the maintenance with the warranty card.
The imaging plate scanner is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment-guidance The imaging plate scanner uses RF energy only for its internal function. RF emission Therefore, its RF emissions are very Group 1 GB 4824 low and are not likely to cause any interference to nearby electronic equipment.
±1kV line to ±1kV line to Mains power quality should be Surge line line that of a typical commercial or GB/T 17626.5 ±2kV line to N/A hospital environment. earth <5 % UT <5 % UT (>95% dip in (>95% dip in Mains power quality should be Voltage UT.) for 0.5 UT.) for 0.5 that of a typical commercial dips, short cycle cycle or hospital environment. interruptions 40 % UT (60% 40 % UT (60% If the user of the imaging and voltage dip in UT.) for dip in UT.
Conducted RF GB/ T17626.6 Radiated RF GB/ T17626. 3Vrms 150kHz~ 80MHz 3V/m 80MHz~ 2.5GHz 3Vrms 3V/m d = 150kHz~80MHz d = 80MHz~800MHz d = 800MHz~2.5GHz Portable and mobile RF communication equipment should be used no closer to any part of the imaging plate scanner, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance d = 150kHz~80MHz d = 80MHz~800MHz d = 800MHz~2.
a. Field strengths from fixed transmitters, such as base stations for radio (cellular/ cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
For the rated maximum output power of transmitters not listed in the above table, the recommended separation distance “d” in meters (m) can be determined by the formula in the corresponding transmitter frequency column. Here “P” is the maximum output rated power of the transmitter in watts (W) provided by the transmitter manufacturer. NOTE1: At 80 MHz and 800 MHz, the formula of higher frequency range is applied. NOTE 2: These guidelines may not be suitable for all situations.
Products comply with WEEE directive Authorized Representative in the EUROPEAN COMMUNITY Humidity limit for storage: 10% ~ 93% Atmospheric pressure for storage: 70kPa ~ 106kPa Temperature limit for storage: -20℃ ~ +55℃ 13 Statement All rights of modifying the equipment design, product technology or accessories, instruction manual and packaging content at any time are reserved to Woodpecker without further notice. 14 FCC Statement This device complies with part 15 of the FCC Rules.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
ZMN-SM-318 V1.