User's Guide
1 4
Author: Jan GrothusenIssue Date: 09/05/2011
Doc №: 94-0199-4-A
Operation
The target must always be used with its longest side vercal.
Switch the unit o when not in use to preserve the baery.
!
The target is water resistant to IP66.
However, do not submerge the unit in water.
To Switch the Target ON:
1. Press the ON/OFF buon on the top of the unit.
2. The green light should be permanently lit when unit is in operaon.
Under normal condions with a fully charged baery,
the rechargeable target will operate connuously
for up to 640 hours before it needs recharging.
!
When the unit is switched on and no green light is shown,
then the baery requires charging.
ON/OFF Buon
Power
Light
Charging
The rechargeable target should be fully charged before use.
A full charge takes approximately 24 hours.
!
DO NOT charge targets in an explosive
atmosphere or other hazardous environment.
The target should be switched o while charging. (Both lights o).
To Charge the Target:
!
Note: Only use the
supplied charger.
1. Switch the target o and unscrew the charging socket cap on the
rear of the unit.
2. Connect the supplied mains charger (Part № 39-0033-2).
(Input: 100–240VAC, 50–60Hz, 1.5A Output: 24VDC, 2.5A, 60W).
3. When charging is complete, disconnect the power from
the unit and replace the charging socket cap.
Rechargeable Target—Rear
Charging
Socket
RadaScan Mini-Target Guide
ATEX Cercaon Label Mini-Target
Mini-Target—Front
Instructions for Safe Selection, Installation, Use, Maintenance, Repair and Transport
User instrucons (in compliance with ATEX 94/9/EC Direcve, Annex II, 1.0.6)
Mini Target Part Numbers: 20-0108-1 and 20-0110-1
ATEX Certificate Number: SIRA 10ATEX2254X
Use in Hazardous Environments
X Targets may be used in zones 0, 1, or 2 with ammable gases.
X Targets may be used in the presence of ammable gases and vapours with
apparatus groups IIB or IIA and with temperature classes T1 or T2 or T3 or T4.
X The equipment is cered for use in ambient temperatures in the
range of −25°C to +55°C and should not be used outside this range.
Installation and Maintenance
X Targets must be installed by suitably trained personnel in accordance
with the applicable code of pracce (typically IEC EN 60079-14).
X Targets must be inspected regularly by suitably trained personnel in accordance
with the applicable code of pracce to ensure they are maintained in a sasfactory condion.
X Targets are not intended to be repaired by the user. They must only be repaired or serviced by Guidance Navigaon Ltd,
or by an approved service representave of Guidance Navigaon Ltd, in accordance with the applicable code of pracce.
X Targets do not require assembly or dismantling.
They do not contain any customer-replaceable parts, and no user adjustment is required.
Electrostatic Hazard
X Targets must not be installed where external condions could cause an electrostac build-up on their outer casing.
X The target’s outer casing presents a stac hazard and must only be cleaned using a damp cloth.
Corrosive Substances
X Targets should be protected from solvents, or acidic gases or liquids that may aect the integrity of its outer case.
Transport
X Targets must be transported in a suitable transit case.
Mini-Targets can be used with RadaScan and Mini-RadaScan systems.
One or more targets should be mounted on the target plaorm or vessel.
There are two models of Mini-Target:
X Rechargeable (Part № 20-0108-1-S2-*)
X Non-rechargeable (Part № 20-0110-1-S2-*)
(The non-rechargeable variant requires baery pack replacement as roune
maintenance. This should be undertaken by Guidance Navigaon Limited,
or a suitably qualied service technician).
!
Do not open the target. It should only be serviced by Guidance Navigaon
Limited, or a suitably qualied service technician.
If you experience any problems with the unit, please contact:
Guidance Navigaon Ltd
4 Dominus Way
Meridian Business Park
Leicester Tel: +44 (0) 116 229 2600
LE19 1RP Fax: +44 (0) 116 229 2604
United Kingdom Email: radascan@guidance.eu.com
RadaScan Mini-Target
INTRINSICALLY SAFE
Part And Serial Numbers:
*20-01XX-X-X MRT100XXXX*
20-01XX-X-X MRT100XXXX
4 DOMINUS WAY, LEICESTER, ENGLAND, LE19 1RP, UK
TEL: 44 116 229 2600 FAX: 44 116 229 2604
II 2G
0359
WARNING
POTENTIAL ELECTROSTATIC
CHARGING HAZARD
SEE INSTRUCTIONS
HAZARDOUS LOCATION DESIGNATION
I.S. FOR Cl.I, DIV.1, GRPS C,D, Temp. Code T4
Class I, Zone 0 AEx ia IIB T4
SIRA 10ATEX2254X Ex ia IIB T4 Gb
(Tamb = -25C to +55C)
POWERED BY BATTERY PACK 39-0034-2
(Series 2)
US
CSA 2368857