These instructions provide a quick reference for installing the G-Prox II™ family
of intelligent (jumper-free) proximity readers, and the G-Prox series I (HID™-
compatible readers). These units are weather-resistant, and the G-Prox II
readers are auto-programmable using special programming cards.
These readers can be used with any type of door controller that supports
standard Wiegand readers (with 12 V
DC
output). The arming station is
supported by Monitor ISM/AFx systems.
Cards
: G-Prox II readers = G-Prox cards; G-Prox series I = HID comp. prox. cards.
Switch-plate
Reader
111-82x4
Mullion
Reader
111-8289
Switch-plate
Keypad
111- 82x0 (Arming)
Mullion Reader
Keypad
111-8267(Arming)
Switch-plate
Reader Keypad
111-82x1 (Weigand)
111-82x3 (Matrix)
Mullion
Reader
Keypad
111-8266
(Wiegand)
Poducts
Mullion Part Numbers: 111-8266, 111-8267,
111-8289.
White Grey Black
GProx I 111-8220 111-8240 111-8310
GProx I 111-8221 111-8241 111-8311
GProx I 111-8223 111-8243 111-8313
GProx I 111-8224 111-8244 111-8314
GProx II 111-8270 111-8280 111-8290
GProx II 111-8271 111-8281 111-8291
GProx II 111-8273 111-8283 111-8293
GProx II 111-8274 111-8284 111-8294
System Cabling Reference
Recommended reader cabling is 24
AWG, shielded.
(max 150 m / 500 feet).
For reliable operation at max. distance,
reader cabling must be less than 27 pf
per foot.
Number of Conductors Needed:
Typically 6
conductors. Will need
one or two more wires for external
buzzer control (if supported).
Check the wiring tables to verify the
number of conductors.
Note: A G-Prox II™ reader with Matrix-style keypad requires a second cable with the same
specifications (8 conductors needed). Max. length: up to 150 m / 500 feet. These can be used with
a door controller that supports a Wiegand reader with matrix keypad.
!!! Do's & Don’ts !!!
Notice: Do all wiring with the door controller
powered down, or ensure the +12V is
never connected without the 0V/Gnd first.
Static can destroy electronic
components! Always take proper
precautions when handling or
transporting devices.
Remove power before servicing readers
or other electronic components.
Always conform to local fire and building
regulations (if unsure, find out).
Specifications
Environment: -35 to 66° C (-31 to 151°
F), 5-95% relative humidity
(non-condensing) at 25° C (77° F).
Weather resistant.
Power: 12 V
DC
(or 13.8 V) regulated,
@100 mA (typical);
Data Output: Standard Wiegand;
Cable Routing
Be sure to distance all cables from
sources of electromagnetic interference
(motors, fluorescent lights, etc.).
Grounding
Ground the reader cable shield only at
the door controller earth ground.
G-Prox Series I DIP Switches
G-Prox series I readers have DIP
switches accessible from the back. (Set
switches only when powered down.)
(9 = factory default)
Switch 1 ON = High Volume 9
OFF = Low Volume
Switch 2 ON = Buzzer (+) trigger
OFF = Buzzer Gnd trigger 9
Switch 3 ON = Pull Up on Data Lines
OFF = No Pull Up 9
Switch 4 ON = No Beep on key press
OFF = Beep on key press 9
Switch 5 ON = No Beep on Card Read
OFF = Beep on Card Read 9
Switch 6 ON = No Flash on Card Read
OFF = Flash on Card Read 9
Switch 7 ON = Red if both LED lines on
OFF = Green if both lines on 9
Switch 8 ON = Dual LED Mode
OFF = Single LED Mode 9
G-Prox II Programming
These intelligent (jumper-free) readers are
auto-programmable using special cards.
Supported features include:
Operation of the door state LED;
How a 'card read' will be indicated;
The type of circuit to be used with the
reader buzzer (active high vs. Gnd.);
Whether cards must be encoded with a
specific lock code.
For details on the programming cards, refer to "G-Prox II Programming" (pg. 2),
plus the on-line help or User's Guide for the G-Prox Desktop Programming Station.
Defaults: LED: Bi-colour; Keypress beep: Yes; Lock Code: 1 (card default);
Buzz: Ground trigger; Card Read: LED & Beep.
Cabling P/Ns: FT4 FT6
Module Bus (shielded)
Preferred (24 AWG): 120-3401 120-3405
ULC (22 AWG): 120-3408 120-3409
Note: Max. distance may be reduced with the ULC cable.
Reader cable (24 AWG shielded):
6 Conductors: 120-3402 120-3406
10 Conductors: 120-3403 120-3407
Note: ULC requires 22 AWG shielded cable.
Power (18 AWG): 120-3400 120-3404
I/O
(quad): 120-3410 120-3411