3.3.19 NET TOOL PRO NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. (1)IP address scan Connect the cable to the LAN port. Set your IP address search range by changing the Start and End IP addresses. Click the "Start" button to scan the IP address range. You can also input an IP address in the Port Number Scan to scan for open ports. Page.57.
(2)PING Test PING is the most conventional network debugging tool, it is used for testing if the connected IP camera or other network equipment's Ethernet port is working normally and the IP address is correct. Connect a network cable to the LAN port and click the icon to open the PING tool. You can set your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet time and Timeout. Press "Start" to start pinging.
When test, need a tester or a computer installed Network Test Software as the Server, the other tester sends packet test. The two testers must be in the same network segment. a). Start the server: Click "Start Server" button to use the tester as a Server. It will display its IP address at the top of the screen. b). Start send packet test: Using the other IP tester, type in the Server's IP address at the top right corner of the screen. This app is used to send packets for network speed testing.
Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester. If use computer as the server, the computer IP address is :192.168.0.39 Tester as Client, tester's IP address is:192.168.0.238. The Server and the Client are at the same network segment, but with different IP address. Input Server's IP address 192.168.0.
Or use tester as a Server, computer as test Client(select Client, input tester's IP address to test) When use tester as Server, shows results: (4)Port Flashing Connect a network cable to the meter's "LAN" port, click the icon to open the Port Flashing app. Click "Start". The IP tester sends a unique signal to make the connected LAN port of the switch flash.
Application: The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection. (5)DHCP server Click on the DHCP icon to open the DHCP server app. Select the "Start" check box at the top and make any desired changes to the network settings.
(6)Trace route It is used to determine path of the IP packet access target. Note: Trace route testing results only for reference, for accurate test route tracking, Please use professional Ethernet tester. Click to enter trace route Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally default is 30 Click "start" to trace the goal address (7)Link monitor Click the icon to open the Link Monitor app.
Application: Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied. 3.3.20 PoE power / DC12V 3A and DC 5V 2A USB power output When the tester is turned on, the DC 12V and DC 5V power output functions are automatically turned on.
Note: 1. Don't input power into the "DC12/3A OUTPUT" port. 2. Don't output this DC12V/3A power to the DC12V/IN port of the IP camera tester to avoid destroy 3. The IPC tester power output is close to 3A, if the IP camera's power is over 3A, the tester will auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester. 4. Before turning on the PoE power output, please make sure the IP camera supports PoE power.
the camera. Notice: a. Don't input any power into the "DC24V/2A OUTPUT"port of the tester to avoid destroy. Man-made damage is not within our company's warranty b. Don't output this DC24V/2A power to DC12V/ IN port to avoid destroy. otherwise the tester will damage, and man-made damage is not within our company's warranty. c. The IPC tester power output is close to 2A, if the IP camera's power is over 2A, the tester will auto enter protection mode.
If need several different number other types cable testers, should pay the additional cost. Cable test Tap "cable test sketch map", pop up Straight-through cable and crossover cable sketch, It is for line sequence reference, when the crystal on the first pressure in the twisted-pair. 3.3.23 RJ45 cable TDR test Connect cable to tester's LAN port, click icon " " to enter RJ45 cable TDR test app. Single test: Test cable status, length and attenuation. Page.67.
Repeat test: Continue to test cable status, length and attenuation. Status: After link up, screen display "online", if not link up or open circuit, screen display "open circuit", if cable pair is short circuit, screen display "short circuit". Length: The max test length is 180 meters, when cable is open circuit or short circuit, can test the cable length, if screen display "online", the testing result would be not accurate.
Click "Help" to check the instruction of all parameters. 3.3.24 Cable Tracer ( *Optional ) Connect tested cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port on the bottom. Click icon to enter, click the Number on the screen to adjust audio type. Page.69.
UTP mode is used for searching the normal network cable or other cables. STP mode is used for searching the shielded network cable. Rotating the switch of cable tracer to turn on. Clockwise rotation increases sensitivity, anticlockwise rotation reduce sensitivity. Cable tracer and Cable tester can be tested at the same time. It is better to judge whether the search network cable is accurate.
Note: The battery of the cable tracer must according to corresponding positive pole + and negative pole -, otherwise will damage the tester. Note: While the cable tracer tester is receiving the audio signal from the tester, it may be influenced by other signals and make some noise. 3.3.25 TDR cable test ( *Optional ) Note: The testing cable can't be connected to any equipment, otherwise it will damage the tester.
Open (break point): The curve shows a downward trend after the inflection point 2) Curve operation Zoom: Zoom the curve. Click icon "zoom", tap the curves by two fingers or use virtual keyboard (tap the icon of the screen left edge, to call virtual keyboard) Move: Move curve, click icon "move", and drag the curve to move. Distance bar: Display the current length, and use the virtual keyboard to move distance bar.
User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click "Cable", "Type" to select user-defined 1 for calibration, 11 groups user-defined can be set. 1. Select user-defined and click "Calibration" to enter test, click "user-defined 1" can define cable name, such as: AiPu BNC-5 2. Click "Cable", "Type" to select cable, and corresponding type, for example, if testing BNC cable, select "BNC", if testing communication cable 75-2, select SYV 75-2. 3.
Application: TDR test is the use of pulse reflection method, to transmit pulse signal for tested cable, when cable is open circuit or short-circuit, reflected pulse is generated, the tester receives and deals with the reflected wave, measurement results displayed on the screen. TDR can test cable open circuit and short circuit, help engineer quickly find the cable's problem location. It is more convenient and efficient to repair the faulty cable.
2.After calibration, the red clip clips the copper core of the BNC cable, and the black clip clips the outer envelope of the BNC cable. attenuation value will be displayed after connection, as below: 3.Click "Reset", the application will restore factory defaults. 3.3.27 PoE Voltage test Click icon to enter PoE voltage measurement Page.75.
Connect a network cable from a PoE switch to the IP tester's PSE IN port. Connect an IP camera or other PoE using node to IP tester's LAN port, the PoE voltage and the cable's pin connection status show on the screen. Note: This test if for measuring the voltage being drawn by the PoE node and the IP tester must be between the PoE switch and the PoE node for this test to work. Note: The PoE switch must be connected to the PSE IN port.
Warning: Not allow connect device with input power over 17V to tester "12V IN" port, otherwise it will damage the machine. 3.3.29 Digital Multi-meter Click icon ( *Optional ) to enter. 1) SYMBOLS: U: DC Voltage Measuring A: DC Current Measuring Page.77.
Ω: Resistance Measuring ~ U: AC Voltage Measuring : Diode Testing ~ A: AC Current Measuring : Continuity Testing AC/DC : Capacitance Measuring Voltage and current measurement state display Auto- range Data hold The Multimeter auto adjust the range by input signal or tested components Hold data Display the relative measurement value Relative measurement Press the key to change display state 10A socket In 10A current measurement state ,indicate use 10A socket Over range The current measurement va
000.0V 660.0V range 000.0mV 660.0mV rang B. AC Voltage Measuring WARNING! You can't input the voltage which more than 660V AC, it's possible to show higher voltage, but it's may destroy the inner circuit. Pay attention not to get an electric shock when measuring high voltage. a. Connect the black test lead to the "COM" jack and the red test lead to the "V/Ω" jack. b. select U ~ , enter the AC voltage measurement. C. The tester default Auto range status, by click "AC auto range" d.
00.00mA 66.00mA range 000.0mA 660.0mA range 00.00A 10.00A range(use 10A socket) d. Select the range to enter current measurement NOTE: When only the figure "OL" is displayed, it indicates over range situation and the higher range has to be selected. When the value scale to be measured is unknown beforehand, set the range selector at the highest position. The maximum current of mA socket is 660mA, over-current will destroy the fuse, and will damage the meter.
c. Manual range: 0.000mA 6.600mA range 00.00mA 66.00mA range 000.0mA 660.0mA range 00.00A 10.00A range(use 10A socket) Note: When only the figure "OL" is displayed, it indicates over range situation and the higher range has to be selected. When the value scale to be measured is unknown beforehand, set the range selector at the highest position. The maximum current of mA socket is 660mA; over-current will destroy the fuse, and will damage the meter.
00.00 KΩ 66.00KΩ range 000.0 KΩ 660.0KΩ range 0.000 MΩ 6.600MΩ range 00.00 MΩ 66.00MΩ range F. Continuity Testing WARNING! When testing the circuit continuity, be sure that the power of the circuit has been shut down and all capacitors have been discharged fully. a. Connect the black test lead to the "COM" jack and the red test lead to the "V/Ω" b. Select jack. , enter the continuity test, Connect test leads across two point of the circuit under testing. c. If continuity exists (i.e.
H. Capacitance Measuring WARNING! To avoid electric shock, be sure the capacitors have been discharged fully before measuring the capacitance of a capacitor. a. Connect the black test lead to the "COM " jack and the red test lead to the "V/Ω " jack. b. Select " ", enter the capacitance measurement. c. The tester default auto range status, and manual range by press upward and downward key, Auto rang by press the key "NEAR" Manual range: 0.000nF 6.600nF range 00.00nF 66.00nF range 000.0nF 660.
Manual range and Auto range When testing, click "Range select" to change the value, click "Auto range" to enter Auto measurement. Data hold Click "Hold data" to enter, the data be hold, the value is green. Press it again to quit. Relative value measurement Click "Relative "to enter, the tester Auto-save the data, the displayed new measurement and relative value is red color. Press it again to quit.
change the fuse, Pls opens the battery cover to change. Note: 10A socket without fuse protection, if over the current range Wrong using the 10A socket to measure the voltage, will damage the meter. 3.3.30 Optical power meter Click icon ( *Optional ) to enter ,with five wavelength 1625nm,1550nm, 1490nm, 1310nm,1300nm, 850nm, linear or nonlinear optical power display, both for optical power testing and Fiber link loss relative measurement.
the displayed new measurement and relative value is red color. Press it again to quit. Data hold and Relative measuring use together, the data is yellow while the function is effect. Page.86.
3.3.31 Visual Fault Locator Click icon ( *Optional ) to enter VFL four status can select——"Steady mode", "Evasive 1Hz","Evasive 2Hz"and "Time off". Click button "Steady mode" to enter steady status, click button "Evasive 1Hz" and "Evasive 2Hz", to enter pulse mode, click button "Time off ", VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60 mins and 120 mins). Click "Steady mode", red laser source emits steady, click again to quit.
3.3.32 Audio Record Connect an audio device to the IP tester's audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop, and the unit will prompt you to save the recording. 3.3.33 Data monitor Please click icon to enter Click "Setting" to choose the baud rate of RS485, it must be the same as the DVR or the Control keyboard.
3.3.34 Audio player Click the icon to enter . The audio player only supports MP3 format Audio files. 3.3.35 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4, and MKV. The IP tester recorded files can play directly via the Media player. The Media player will automatically display the video files from the SD card. Click on the desired file to play. Click RETURN to exit.
3.3.36 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video. From the main menu, select the "APP Tool" folder and then select the "RTSP Player" to open the app. If the IP camera uses MJPEG, select the RTSP icon. If the IP camera uses H.264, select the "RTSP HD" icon. Page.90.
Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera's RTSP URL or click on Search to search the network for cameras that use an RTSP stream. IPC Username: Enter the IP camera's user name. IPC Password: Enter the IP camera's password. Once you have entered all the necessary information, select Enter at the bottom left to view the RTSP stream.
"Activation" and "Batch activation" are optional. Auto open ONVIF protocol: After activation, the new HIK cameras click "play, modify the channel name, modify network information, modify user information" any one of to auto open the selected camera ONVIF protocol. Play: Security status shows the "activated" camera. Enter the correct camera password in the right [password] and click [play] to pop up the "private protocol" or "speed ONVIF" two options. Select the protocol you need to see the camera images.
Modify channel name: Clicking "Modify the channel name" will pop up OSD settings, including time, channel name and other optional items. After channel selecting, you can edit the channel name, modify the display position, and switch the font size. Select "default location" in "content location" is without modification. Select "Customization" to arbitrarily adjust the channel name and display location. Click"OK"and the effects will appear.
and other parameters modification. Enter a new IP address and subnet mask, the default gateway will be auto modified according to the IP address. Click "OK" to save the changes. Modify user information: Modify the camera's user name and password. Page.94.
Factory Reset: Camera factory reset. 3.3.38 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera, it can display image, and modify IP, user name and password etc. Making Dahua camera test more convenient and quickly. Page.95.
Activation: select left [online detection] to display the "inactivated" camera and click activate. Activate and Batch activate are optional, support reserved phone number for resetting password. Page.96.
Play: When mode display "activated" camera, input correct password, click "Play" poping up "private protocol" and "ONVIF", Select correspond protocol to view the camera image. Modify Channel: Click "Modify Channel", will pop up OSD setting, includes time, channel name,etc Page.97.
After selected Channel name, can edit channel name, modify the display position and font size. If select "Default position" of Content location, then no need to modify. If select "customize", then can modify Channel name and display position, click "OK"to view the image. Click "Back" or "Return" button to return previous interface. Modify Network: Support Modify and batch modify two way, can modify camera IP address, Subnet mask and gateway. Page.98.
Input new IP address, need to input password, click "OK" to save the modification Modify user information: Modify camera user name and password, which is onvif, Dahua test tool, IPC TESTE user name and password, not web user name and password. Page.99.
Factory reset setting: Camera will be soft reset, and the device's user name, password and network set be saved. Other settings information is factory reset. 3.3.39 Update Copy the downloaded update file to SD card "update" directory, if no directory, please create one. Click the icon to open the Update menu. Select "Local Update" to update via the SD card or select "Online Update" to check for updates on the internet.
If there are update programs, applications will be listed in the interface, click related applications, update to the latest version. Update online: Before using online update, need enter settings-user management to register first. System update: Connect the Internet to update systems. 3.3.40 Office Quick office app (support excel, word, ppt format) doc. editable Page.101.
3.3.41 LED Flashlight It is convenient for the installation or maintenance in the evening or in the dark. Click icon to enter While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don't press the red button to shut off the lamp and press the button to exit the app, the lamp will stay on. Click the Time Setting button to set a timer that will shut off the lamp. 3.3.
camera. If they are not in the same segment, click the button or press "RETRUN" to exit. Open the "Settings" app from the main menu to change the IP tester's network settings to match those of the IP camera. 3.3.43 Notepad Notepad can be used to record the important testing results, click the key "Save" to save the contents. Notepad can auto record the storage date and time. . Please click to view the notepad, all saving contents display. Click each record bar to show the details.
3.3.44 System Setting Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish, Spanish, French or Japanese, German,Turkish,etc. Typewriting: You can select typewriting or install other typewriting: Date/Time: Set the Date/time of the IP tester IP setting: Manually set the IP address, Subnet Mask, Default Gateway and DNS address or select "Dynamic allocation" to use DHCP. To test multiple network segments, click "Advanced " and then Page.104.
click "Add " to enter another IP address for the IP tester. After setting an advanced IP address (refer to the photos above), the unit can test two network segments (192.168.5.0) and (192.168.1.0) WLAN Net: Turn WiFi off or on by pressing the "Open the wifi" button. Once WiFi is turned on, and click connected WIFI, it will scan for wireless networks in your area. Select and press "WIFI" several seconds, to set static IP address. Page.105.
Wi-Fi hotspot: Input "SSID" name and "password", and then click "ok" to create Wi-Fi hotspot. Brightness: Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level SD Card: Displays SD Card Capacity. You can also format the SD card or unmount it before removing it. FTP server: Once the IP tester connects to a network, a computer can be used to read the SD card files via FTP Page.106.
Start the FTP server and then input the tester's FTP address in the PC's address bar. This will enable the PC to read, copy and edit the files from the SD card without the use of SD card reader. Version Information: Shows applications version information, if press any apps icon several seconds to uninstall. Screen display rotation: Click on "Screen Rotation" to flip the IP tester's display 180 degrees.
and write your feedback. Lock Screen: The meter default is not locked. You can choose password Lock screen, pattern Lock screen or "NO". Password Lock Screen: Set password, you can input digitals, letters or characters as password, input it again to confirm .when the meter is in standby mode or turn it on, you can input your password to enter. Pattern Lock Screen: Drawing a pattern to lock. While the meter is in standby mode or turn it on, you can input your pattern to enter.
FTP server You can choose internal or external SD card. Other operation details, Please refer to FTP settings. Page.109.
3.3.46Audio test You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP tester with the supplied audio cable. 4. Specifications 4.1 General Specifications Model Display Network port IP Camera Tester【*】models Optional New 7 inch retina touch screen, 1920*1200 resolution 10/100/1000M auto adjust, RJ45, Dual LAN port Built in WIFI, speeds 150M, allows you to connect to a wireless network WIFI H.
Channel, batch modify IP, user name and password parameters etc. Batch activate Dahua camera, batch modify IP, modify Channel, user name DH test tool and password parameters etc. ONVIF, ONVIF PTZ, Dahua IPC-HFW2100P, Hikvision DS-2CD864-E13, IP camera type Samsung SNZ-5200, Tiandy TD-NC9200S2, Kodak IPC120L, Honeywell HICC-2300T, RTSP Viewer Auto-recognize the resolution and Auto-display the image of the connected AutoHD* (Optional) camera.
PEAK video signal level, SYNC signal level, COLOR BURST chroma Video level meter Zoom Image level measurement for CVBS camera. Supports Analog and IP camera image zooming & movement Snapshot, Video Capture current images and record live video as JPG file. Media player will record and playback view photos and playback video HDMI IN *(Optional) HDMI output HDMI IN, Support 720×480P /720×576P/1280×720P/1920×1080P /1024×768P/1280×1024P /1280×900P /1440×900P.
Captures and analyzes the command data from controlling device, also can Data monitor send hexadecimal NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex NET TOOL PRO Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP.
Auto off 1-30 (mins) General Working -10℃---+50℃ Temperature Working Humidity 30%-90% Dimension/Weight 240mm x 154mm x 46mm / 620g 4.2 Multi-meter specifications Counts: -6600~+6600 Conversion rate: 3times/s Current modes for clamp meter with ZERO function Isolation: the Multi-meter connector must be isolated with the other connector. DC voltage Range Accuracy 660mV (Manual range) 6.600V 0.1mV ±(0.3%+4) 66.00V Resolution 660.0V 1mV 10mV 100mV AC voltage Range 660.
DC current Range Accuracy Resolution 6.600mA 1uA 66.00mA 10uA ±(0.5%+3) 660.0mA 100uA 10.00A 10mA ±(1%+5) AC current Range Accuracy Resolution 6.600mA 1uA 66.00mA 10uA ±(0.5%+3) 660.0mA 100uA 10.00A 10mA ±(1%+5) Resistance Range Accuracy 660.0Ω Resolution 0.1Ω ±(0.8%+5) 6.600KΩ 1Ω 66.00KΩ 10Ω ±(0.8%+2) 660.0KΩ 100Ω 6.600MΩ 1KΩ 66MΩ 10KΩ ±(1.2%+5) Continuity Range Resolution 660.0Ω 0.1Ω Function The measurement value less 30Ω±3Ω,the tester will sound Page.115.
Diode Range Resolution Function Schottky diode:0.15~0.25V 2.0V 1mV rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V Capacitance Range 6.600nF Accuracy Resolution 1pF ±(0.5%+20) 66.00nF 10pF 660.0nF 6.600μF 100pF ±(3.5%+8) 1nF 66.00μF 10nF 660.0μF 100nF 6.600mF 1μF ±(5%+8) 66.00mF 10μF 4.
-20~+70 Storage Temperature (℃) FC/PC Connector type 4.4 Visual fault locator specifications Laser type LD Wavelength Calibration 650nm Output power 5mW(Optional 10mW,20mW) Modulation mode CW/1Hz/2Hz Measurement Range 5KM(Optional 10-20KM) Connector FC/PC exchangeable Working Temperature -10℃~+50℃ Operating Temperature -20℃~+70℃ The data above is only for reference and any change of them will not be informed in advance.
FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.