SKO.W7601.3 1. Introduction(简介) SKO.W7601.3 module is based on MediaTek MT7601UN/B complied with IEEE 802.11b/g/n standard from 2.4GHz ISM band.This documentation describes the engineering requirements specification. SKO.W7601.3 模组基于 MediaTek 的 WIFI 芯片 MT7601UN/B 开发,支持 2.4GHz ISM 频段 IEEE 802.11b/g/n 标准。本文档描述了产品的设计要求规范。 2. FEATURES(特性) Reserving System 接收制式 IEEE Std. 802.11b IEEE Std. 802.11g IEEE Std. 802.11n Chip Solution 芯片方案 Band 波段 Dimensions 尺寸 model型号 MT7601UN/B MT7601UN/B 2.4G 16mm*18mm*2.
SKO.W7601.3 Package Outline and Mounting(外形及安装尺寸) 4. Pin Definition(引脚定义) 正视图 PIN SYMBOL DESCRIPTION 1 GND Connected to Ground\连接到地 2 WoW 3 RESET RESET\复位 4 GND Connected to Ground\连接到地 5 DP USB2.0 DP Signal\USB2.0 差分正电压信号 6 DM USB2.0 DM Signal\USB2.0 差分负电压信号 7 VCC 5V input\5V 输入 8 VCC 5V input\5V 输入 Q Device Wakeup Host\WIFI 唤醒主机 2
SKO.W7601.3 5.
6. Key Materials(关键物料) No. 序号 Name 关键件名称 Model 型号 Specification 规格/材料 Producer 生产者 1 集成电路 MT7601UN/B QFN40 MediaTek 2 PCB SKO.W7601.3 FR-4,4LAY 福昌发 3 晶体振荡器 2.3.3.400001535 40MHz 明德亨 (MDH) 6 Maximum Input Level (FER ≦8%) -10 - - Remark 备注 dBm 7. General Requirements(一般要求) No. Feature Description 7-1 Operation Voltage 5V+/-0.
SKO.W7601.3 4) 11Mbps - - -10 dB -25 - 25 ppm Min. Typ. Max. Unit 1) 1Mbps (FER ≦8%) - - -83 dBm 2) 2Mbps (FER ≦8%) - - -80 dBm 3) 5.5Mbps (FER ≦8%) - - -79 dBm 4) 11Mbps (FER ≦8%) - - -76 dBm 4. Frequency Error RX Characteristics 5 Minimum Input Level Sensitivity (each chain) 8.2 IEEE 802.11g Section Items Contents Specification IEEE802.11g Mode OFDM Channel CH1 to CH13 Data rate 6, 9, 12, 18, 24, 36, 48, 54Mbps TX Characteristics Min. Typ. Max.
SKO.W7601.3 7) 48Mbps (PER ≦10%) - - -69 dBm 8) 54Mbps (PER ≦10%) - - -65 dBm -20 - - dBm 6 Maximum Input Level (PER ≦10%) 8.3 IEEE 802.11n HT20 Section Items Contents Specification EEE802.11n HT20 @ 2.4GHz Mode OFDM Channel CH1 to CH13 Data rate (MCS index) TX Characteristics MCS0/1/2/3/4/5/6/7 Min. Typ. Max.
SKO.W7601.3 8.4 IEEE 802.11n HT40 Section Items Contents Specification IEEE802.11n HT40 @ 2.4GHz Mode OFDM Channel CH3 to CH11 Data rate (MCS index) TX Characteristics MCS0/1/2/3/4/5/6/7 Min. Typ. Max.
SKO.W7601.3 9. Mechanical,Environmental and Reliability Tests (机械、环境和可靠性测试) Test Items Test Conditions Qty Criteria Condition The packed samples within 100Kg can be tested Drop height: 9-1 Drop test After drop test, the outer box and inner Face Side: 800/600/450mm 1xBox Edge line: 600/450/350mm box will not been broken by appearance visual inspection. Drop time: 1 each Face and edge. X-Y-Z direction, first Frequency changing from 10Hz to 30Hz to 10Hz,amplitude 0.
SKO.W7601.3 Thermostat cabinet temperature: High 9-6 55±5℃ temperature Applied voltage: load life test 110% rated voltage Working After test, leave samples in standard 60 condition for 1 hour and test, Power, EVM and Frequency error shall be satisfied with the test specification.
SKO.W7601.3 12. warning information(警告语) FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
SKO.W7601.3 This radio transmitter 2AR82-SKOW7601301 has been approved by Federal Communications Commission to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device. Frequency (MHz) 2412-2462 Antenna Type Metal Antenna Gain (dBi) 1.
SKO.W7601.3 This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20centimeters between the radiator and your body. Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu'aucune autre antenne ouémetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres entre le radiateur et votre corps.