RL865 Micro-power Multi-protocol Reader User Manual ◆ Before you use this product, please read this manual carefully, and properly keep it for future reference. ◆ As our products continue improving, they may be changed without advanced notice. ◆ The copyright of this manual belongs to our company. Unauthorized plagiarism or dissemination will be held legally responsible.
Version:V1.
User manual Contents 1. Product Overview ........................................................................ 1 1.1. Introduction.............................................................................. 1 1.2. Product Features ...................................................................... 1 1.3. Pictures .................................................................................... 1 1.4. Main Parameter ........................................................................
User manual 1. Product Overview 1.1. Introduction RL865 is a micro-power multi-protocol reader with high sensitivity reading and writing performance and fast anti-collision processing algorithm which supports reading multiple electronic tags of various protocols at the same time. This product is widely used in desktop card issuance, access control, electronic bills, Libraries and other fields. 1.2. Product Features ➢ Operating frequency: 13.
User manual 1.4. Main Parameter The technical parameters of the reader are as follows: Table 1 Description of main technical parameters of the product Parameter Description Operating Frequency 13.56Mhz Support Standard ISO 15693、ISO 14443A、ISO 18000-3M3 Communication Interface USB Voltage 150mA /5V Maximum Recognition Distance ISO 15693:11cm ISO 14443A:7cm Standard Sizes 54×34.
User manual 3.
User manual the configuration tool and find the file in the folder directory. Double-click this file to open the configuration tool, as shown below: Figure 5 R-Tool connection interface Since the device is connected via USB, you need to select "USB" in the [Communication Interface] item under [Search Parameters].
User manual Figure 7 Enter the device configuration and test interface 4.2. Configuration Description Of Parameters 4.2.1. Communication Interface Figure 8 Configuration interface for communication interface ⚫ Bus Address: between 1-255 ⚫ Baud: baud rate: 9600, 19200, 38400, 57600, 115200, 230400 ⚫ Parity: parity check type: None, Odd, Even Guangzhou Andea Electronics Technology Co., Ltd. http://www.gzandea.
User manual 4.2.2. Buzzer Default Parameters Figure 9 Configuration interface for buzzer default parameters ⚫ Type: Unchanged, On, Off, Flash. ⚫ Frequency: value range from 0 to 255, only applicable for the "Flash" type. ⚫ Active time: the frequency of buzzer, only applicable for the "Flash" type. Note: The device V00.02 and above (including V00.02 version) supports this function (buzzer is required). 4.2.3.
User manual device will automatically close the RF if it does not receive a command of card reading or opening the RF. 2)Timing for Auto Close RF:Value range: 0-256, the RF enters the idle mode if no operation in a specified time. ⚫ Air protocol selection 1) ISO15693: Enable to count tags of ISO15693 air protocol. 2) ISO14443A: Enable to count tags of ISO14443A air protocol. 3) ISO18000p3m3: Enable to count tags of ISO18000p3m3 air protocol. 4) ISO14443B: Enable to count tags of ISO14443B air protocol.
User manual 4.2.4. Inventory Parameters Figure 11 Configuration interface for inventory parameters ⚫ Basic options 1) Disable anti-collision: whether to turn off anti-collision function. 2) Beep when discovery tags: set whether the buzzer buzzes when the tag is detected. 3) Only read new tags: each tag is only read once, when it does not leave the antenna sensing area. 4) Stop Trigger Try N times when no tags: set the number of attempts if no new tags are found.
User manual ⚫ ISO14443B 1) AFI: 00-FF.Note: 00 means not to enable. 2) Slot Number: 1,2,4,8,16. 4.2.5. System Work Mode Figure 12 Configuration interface for system work mode ⚫ Mode: 1) Host mode: the host software needs to send commands. 2) Scan mode: the inventory can be automatically completed, even if the host software does not send commands; scan setting in the scan mode should be configured in advance.
User manual ③ Output format of block’s data: A. Format as hex string. B. Format as ASCII. ④ Output format of UID: A. Format as hex string. B. Format as LSB 3 bytes convert to integer string. C. Format as LSB 4 bytes convert to integer string. D. Format as compliant with Wiegand. E. Format as compliant with Wiegand fix 8 bytes. ⑤ UID length: 0-8, 0 for unlimited length, output of a complete UID. 4) Parameter of reading block with ISO15693 Byte offset: the offset of the first byte to be read.
User manual Figure 13 Multi-Tag inventory test steps Note: Step 1: Select the menu "ISO Multi-Tag Test" in the main interface of the software; Step 2: Select the "Inventory " in the drop-down list above the "Start" button; Step 3: Click the "Start" button to carry out the inventory testing. 4.3.2.
User manual Note: Step 1: In the software main interface, select the menu "Single Tag Test"; Step 2: In the "Single Tag Test" interface, select the type of tag to be operated; Step 3: mode: none address, address. 1) For a single tag, select the "none address" mode. 2) For multiple tags, select the "address" mode. Step 4: Click the "Inventory" button to display the UID list in UID drop-down box.
User manual 5. Technical Support ➢ Download link for development data and testing https://www.gzandea.com/download.php ➢ Call for equipment debugging and technical support Mobile phone: 138 0251 4535 180 2712 4253 Fixed telephone: 0086-20-32039552 Guangzhou Andea Electronics Technology Co., Ltd. http://www.gzandea.
User manual Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s).
The module in this product is labeled with its own FCC ID No. and IC ID No.. The FCC ID and IC ID and is not visible when the module is installed inside another device. Therefore, the outside of the device into which the module is installed must also display a label referring to the module. The final end device must be labeled in a visible area with the following: “Contains FCC ID: 2AFI8-RL865” “Contains IC:26251-RL865” Le module de ce produit est étiqueté avec son propre FCC ID No. et IC ID No..