RD21XX series High Frequency Medium Power Reader User Manual ◆ Before you use this product, please read this manual carefully and properly keep it for future reference. ◆ As our products continue improving, they may be changed without advanced notice. ◆ The copyright of this manual belongs to our company. Unauthorized plagiarism or dissemination will be held legally responsible. Version:V1.
User manual Safety Instructions ⚫ Modification of the equipment without permission or use additional equipment not sold or recommended by the equipment manufacturer may result in fire, electric shock or personal injury. We are not responsible for damage caused by this behavior. ⚫ If the equipment breakdown, it can only be repaired by the manufacturer. ⚫ Installation, operation and maintenance procedures can only be carried out by professionals.
User manual Contents 1. 2. 3. 4. 5. 6. 7. 8. Product Overview ...................................................................................................1 1.1. Introduction ...................................................................................................1 1.2. Product Features ............................................................................................1 1.3. Product Model ..........................................................................................
User manual 1. Product Overview 1.1. Introduction RD21XX series high frequency medium power reader has high sensitivity read-write performance and adopts fast anti-collision processing algorithm. The product supports electronic tags that comply with ISO 15693 and ISO 18000-3M1 standard, and the reading speed of tag is up to 70 pieces per second.
User manual 1.3. Product Model RD2101 RD2104 1.4. Main Parameter The detailed technical parameters of this series of products are as follows: Table 1 Description of main technical parameters of the product Parameter/Model Operating Frequency Support Standard RF Power Antenna Interface Communication Interface Working Mode RD2101 RD2104 13.56 MHz ISO/IEC 15693 和 ISO/IEC 18000-3M1 0.25~1.5W(configurable, the system default setting is1.
User manual Supply Voltage 12VDC Maximum Power Consumption 10W Shell Material aluminum alloy Dimensions 123×105×25mm Maximum Operating Temperature 40℃ ① Product specifications are approximate, please refer to the actual size; ② Due to continuous improvement of our products, technical parameters are subject to change without notice. 2. Hardware Interface Description 2.1.
User manual 2.2. Antenna Interface This product uses an external antenna port design. Different models have different numbers of antenna interfaces.
User manual ⚫ When connecting an antenna, ensure that it does not exceed the permissible limits as prescribed by the national regulations for RF devices. 2.3. Power Interface The power interface of this product uses a standard DC power socket (Ø5.5*2.1mm, length of 8.0mm with thread ) and the power supply voltage is DC 12V, as shown below: Figure 4 Power interface Note: To reduce noise, the power cord can be equipped with a 28 mm x 20 mm EMC ring core.
User manual ⚫ Baud rate: 38400 ⚫ Data bit:8 ⚫ Parity check: even parity ⚫ Stop bits:1 RS232 interface pin definition: Figure 6 RS232 interface for host communication (DB9 connector) Table 3 Pin definition of RS232 interface Pin Definition Description 1 COM Relay port: common port 2 PC-TXD RS232 data output 3 PC-RXD RS232 data input 4 IN1 data input 5 GND Ground 6 NC Relay port: normally closed port 7 NO Relay port: normally open port 8 RS485-B DATA- 9 RS485-A DATA+ Fig
User manual 2.4.2. Ethernet Interface The reader has an RJ-45 network port for integrating 10/100 base-T. To ensure reliable data transmission, it is recommended to use the shielded twisted pair STP CAT5 cable for connection. Figure 8 LAN interface for host communication ⚫ Communication protocol: TCP/IP ⚫ Default IP address: 192.168.0.222 ⚫ Default subnet mask: 255.255.255.0 ⚫ Default gateway address: 192.168.0.
User manual 3.
User manual electrified. Blue light is off: the antenna interface is set to output without electricity. ANT1~ ANT4 Antenna port RF indicator light When RF of the antenna is open, the yellow light will always be on. Otherwise, the light is off. 4. Installation Instructions This product provides holes for installation in the housing, so there is no need to open the housing during installation. The installation dimensions are as follows (unit: mm): Figure 11 Reader installation size 5.
User manual reader separation design. Therefore, when the reader is working , one or more antennas must be connected to read and write electronic tags normally (up to 4 antennas can be connected). Customers can choose different antennas according to the actual needs of the project. Tighten the connector clockwise when connecting the antenna feeder to the reader antenna connector.
User manual Antenna AC 220V DC 12V Power USB data cable Figure 13 Schematic diagram of using USB communication connection Antenna AC 220V DC 12V Power Network cable Figure 14 Schematic diagram of using Ethernet port connection 6. Device Configuration And Test Instructions Refer to Chapter 5 "Device Connection" to connect the device and power on the reader.
User manual Figure 15 R-Tool connection interface Select the corresponding communication method according to the actual interface type used by the device. ① When connected by RS232 interface,choose "COM" from [Communication] under [Search parameters]. Choose "All" for [COM name], set [Baud rate] as 38400, set [Frame] as 8E1, and set [address] as 255; ③ ① ② ④ Figure 16 Operation steps when use RS232 interface connection Guangzhou Andea Electronics Technology Co., Ltd. http://www.gzandea.
User manual ②When connected by USB interface, choose "USB" from [Communication] under [Search parameters]: ③ ① ② ④ Figure 17 Operation steps when use USB interface connection ③When connected through Ethernet port, choose "NET" under [Communication] of [Search Parameters]. Click apostrophe button at right of IP address to search corresponding IP. ① ② Figure 18 Operation steps when use LAN port connection Guangzhou Andea Electronics Technology Co., Ltd. http://www.gzandea.
User manual On the "Discover IP" interface, click the [Start Search] button to search for the device: ① ② ③ Figure 19 Operation steps of discover devices by searching IP Click [Select] button to return to equipment searching interface. Choose 9909 port number. Click [Start] button for successful connection and enter into main interface of software configuration. Notice: Following two points should be noticed when use Ethernet port connection.
User manual 6.1. Configuration Description Of Parameters 6.1.1. System Basic Parameters Figure 20 Configuration interface for system basic parameters ⚫ Work mode: the system work mode can be set to "Host mode" and "Auto read mode", which will take effect immediately after setting: A. Host mode: in this mode, after the device starts,it is in a passive state. It responds to and returns results by receiving commands from the host. B.
User manual 6.1.2. Communication Interface Figure 21 Configuration interface for Communication interface ⚫ Bus address: this parameter is mainly used on the RS485 bus. When multiple readers are connected to a bus, different bus addresses need to be configured for each device, with a value range of 1-255. ⚫ RS232/RS485:it needs to be powered on again to take effect after setting.
User manual Static IP: set IP, Mask and Gateway. 6.1.3. RF And Air Protocol Figure 22 Configuration interface for RF and air protocol ⚫ RF parameter: Transmitter power: 250mW ~ 1500mW, the default setting is 1500mW. When RF closed, Keep antenna port open: check to take effect. Enable EMC: check to enable EMC mode.
User manual 6.1.4. Inventory General Parameters Figure 23 Configuration interface for inventory general parameters ⚫ Basic: ① Beep when tag found: if this option is checked, the buzzer will sound when a tag is detected.
User manual A. Attempt N times; B. Max timeout; Value of attempt N: this parameter is only valid when " Exit condition " is selected as A; Max timeout: the maximum time to read a card on an antenna; ⚫ Special application: ① Disable Anti-collision: Disable anti-collision doesn't mean reading only one tag. If it is an inventory of 1 slot, it can read up to 2 tags after turning off this function. If it is an inventory of 16 slots, turning off this function can read up to 16. Tags.
User manual 6.1.5. Read/Write Command Parameters Figure 24 Configuration interface for Read/Write command parameters ⚫ Failed retry N times: For example, the read data block command is likely to fail in a disturbed environment, the anti-jamming capability can be enhanced by trying multiple times.
User manual 6.1.6. Antenna Port Parameters Figure 25 Configuration interface for antenna port parameters ⚫ Enable DC: when checked, the reader antenna interface is output with electricity. ⚫ Default antenna port select: When the reader has multiple antenna interfaces, the antenna is enabled according to the actual connection. Check to enable. 6.1.7.
User manual Figure 27 Configuration interface for data source ① Data field select: UID: whether to output the 64-bit unique serial number of the discovered tag; User block: whether to output the data block content of the discovered tag; Antenna ID: whether to output the antenna ID of the tag; Input status: whether to output the status of the input port; ② Data field parameters: ➢ UID Length: The default is to output all 8 bytes.
User manual Bytes num to read: Starting from the offset byte, read N bytes; Key index: reserve; ➢ Input port select: Optocoupler input: checking indicates that the state of the port is to be read, but the "Input status" in the "Data field select" must be checked firstly. ③ Data format: ➢ UID data format: A. Raw bytes output: without any conversion, directly output 64-bit data stream; B. Hex string output: each byte outputs 2 hexadecimal characters; C.
User manual B. Hex string output; ➢ Others data format: A. Raw bytes output; B. Hex string output; ⚫ Trigger: Figure 28 Configuration interface for trigger ① Trigger way: Periodic trigger, trigger reading data every N milliseconds; ② Periodic trigger parameters: Internal(ms): trigger with an interval of N milliseconds; Inventory count(0 means once): how many times to inventory after triggering.
User manual Figure 30 Configuration interface for serial output parameters ① Output port select: A. None: read-only does not output any data; B. RS232: output data through RS232 interface; C. HID Custom:output data through the HID Custom interface. If use this interface output, the USB interface must be enabled; D. HID Keyboard:The output characters are output in the form of simulated keys, without any software support. It outputs at the place where the cursor of the operating system stops.
User manual Frame option: frame header + data field + separator + data field + Terminator; ✓ Enable header: whether to output the frame header byte; ✓ Enable separator: when the output data contains multiple fields, if the item is checked, the fields are separated by a separator, such as the comma separator "E004050102030405, 01"; ✓ Enable Terminator: whether to output the terminator; ✓ Separator: whether to use the system separator or the custom separator; ✓ Terminator: whether to use the system t
User manual ⚫ Inventory command: ① Reverse UID: the sequence number contained in the data packet of the inventory command is reversed; ② Enable buffer mode: If checked, the buffer mode is used; if not checked, the asynchronous output mode is used. Buffer mode:buffer the read tags in the memory of the reader, and output them after the inventory is finished.
User manual ⚫ Auto close RF power: ① Enable: If it is enabled, after the RF is turned on, it will be turned off when Idle time exceeds the set time. ② RF idle time(100ms): timeout. Note: after the" Auto close RF power" function is enabled, the operation of password authentication for the tag may cause failure. 6.2. Testing 6.2.1.
User manual 6.2.2. Single Tag Operation Testing After entering the main interface of R-Tool test software, select " Single Tag Test" , carry out the procedure as shown in the following figure ①,②,③,④ and ⑤ for tags test: ③ ④ ⑤ ② ① Figure 33 Single tag operation test steps Note: Step 1: In the software main interface, select the menu "Single Tag Test"; Step 2: In the "Single Tag Test" interface, select the type of tag to be operated; Step 3: mode: none address, address.
User manual ① ② ④ ③ Figure 34 Single tag reading and writing steps Steps: 1) Set the data block of the tag to be operated in the Addr drop-down box and the Num drop-down box.
User manual the error identification. Figure 35 System error flag Table 8 Description of system error flag No. Error Flag Description 0 Temperature alarm The operating temperature of the reader is too high.
User manual 6.3.3. Noise The "Noise " function can be used to detect noise on the spot, as shown below: 1. The noise waveform is normal, indicating that there is no interference signal or the interference signal is small in the environment; 2. When the noise waveform has a large square shape or a parabolic shape, it indicates that the environment has interference signals and the interference source needs to be eliminated.
User manual 7. Failure Analysis 1.The reader doesn't respond: Check the power, whether the input power supply voltage is correct; whether the external power adapter is working properly; whether the power socket contacts are secure; whether the input voltage fluctuates too much. Check whether the connection interface of the relevant cable is loose and whether there is any problem with the cable. You can replace the cable for testing. 2.
User manual Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s).
Guangzhou Andea Electronics Technology Co., Ltd. Address: Room 401, Building H, Jingye San Street, Yushu Industrial Park, Economic And Technological Development Zone, Guangzhou. Zip code: 510663 Phone: 0086-20-32039550, 32039551, 32039552 Fax: 0086-20-32039553 Website: http://www.gzandea.