High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Technical Manual Integrated RFID Reader The purpose of the practical manual is to provide the complete hardware appearance parameter, electric parameter, necessary schematic circuit diagram of the high frequency integrated reader and relevant notices for installation and operation.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Table of Contents 1. 2. 3. 4. 5. 6. Brief Introduction...................................................................................................................... 4 1.1 Brief introduction to the reader ........................................................................................... 4 1.2 Effective range of the manual ..............................................................
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 1. Brief Introduction 1.1 Brief introduction to the reader Sygole SG-HR-I series reader is an integrated high frequency RFID read-write device, with the working frequency as 13.56MHz, and can meet ISO-15693 standard, and support RS-485, RS-232 and TCP (POE) communication. The shell thereof is made of high strength engineering plastics.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 2. Safety Instruction The product conforms to CE, UL, EMC and FCC significant safety specification. If you have any query upon the installation environment, please contact with our service representative. It is not allowed to modify or demount the product. If the user violates the requirement, the wireless equipment approval, the CE approval and the manufacturer certification will be canceled.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 3. Application planning for high frequency RFID reader 3.1 High frequency RFID application system 3.1.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.3 SG-HR-I5 Induction Plan View (as shown in shadow part) 1. Transmission window; 2. Sm main working field; 3. Sn second working field; 4. Sc critical field; 5.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd tag passes through the magnetic field gap during the movement from the minor magnetic field to the main magnetic field, RFID reader cannot temporarily communicate with the tag and accordingly the tag is lost. Therefore, for applying the dynamic working mode, it is suggested to select the read-write distance greater than 30% of Sg. Fig. 3.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.6 Front Face of Tag Corresponds to Front Face of Reader Fig. 3.7 Front View for Wrong Installation of Tag Tag can enter the magnetic field area from any direction; in order to maximize the communication distance and obtain better quality, the tag should be installed maximally in parallel with the reader antenna.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 3.1.4 Static and dynamic operations 3.1.4.1 Static mode According to 3.1.1, the magnetic field area of the reader is divided into the recommended working area, the working area and the critical area. The operation in the critical area may cause unexpected results to the data.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 3.2 Reader and tag data 3.2.1 Read distance of the reader The critical distance (Sg), the operation distance and the transmission window length corresponding to different readers are as shown in the following table: Tab. 3.
High Frequency Integrated RFID Reader Write Bytes 8 16 32 64 112 Operation Manual Tag Model SG-HT-243(EEPROM) Time Consumption (ms) 41 63 106 193 323 Guangdong Sygole Intelligent Technology Co.,Ltd SG-HT-244(FRAM) Time Consumption (ms) 35 36 52 85 135 Note: the time mentioned in above table refers to the experimental test data read at a time and is only for your reference.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig.3.10 Demonstration for Nut Type Reader Installation in Metallic Environment If the shell of the reader is made of metal, it is suggested to adopt a plastic support under the condition of poor ground connection, as shown in Fig. 3.11: Fig. 3.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.12 Demonstration of Embedded Installation into Metal Installation of reader into metal framework ---- please avoid conductor ring. Fig. 3.13 Diagram for Annular Metal Framework Installation Mode If a single reader has been installed and surrounded by an enclosed metal framework, the metal framework may absorb the induced current generated by the magnetic field of the reader.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.14 Demonstration of Installation of Multiple Readers in Metal Framework Fig. 3.15 Demonstration of Insertion of Non-metal between Reader and Metal Framework 3.3.3 Notice for tag installation Tag includes two types ---- anti-metal tag and non-anti-metal tag.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.16 Tag Installation Environment 3.3.4 Power supply and wiring requirments 3.3.4.1 Wiring requirements In industrial environment, correct ground connection is the main method for noise suppression and interference prevention, and the main interference of the equipment circuit is sourced from the unreasonable ground wire.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Supported protocol communicatio n interface RS485 RS232 POE Read-write distance 0~150 mm Shell material PC+ABS The products with different communication interfaces have different order models. Specifically, the order model of each product is as shown in the following table: communication interface RS232 RS485 POE Model SG-HR-I5 SG-HR-I5-RS232 SG-HR-I5-RS485 SG-HR-I5- 4.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd female) 1 2 3 4 5 6 7 8 TD+ TDRD+ RDPoEPoEPoE+ PoE+ Orange white Orange Green white Green Blue white Blue Brown white Brown UTP above 8-core network cable 4.3 Physical parameters of the reader The physical parameters of SG-HR-I series readers are as shown in Tab. 4.5: Tab. 4.
High Frequency Integrated RFID Reader Power consumpti on Radio frequency output power Working frequency Protocol standard communi cation interface communi cation speed Operation Manual <=1.2W 23dBm 13.56MHZ ISO15693 RS485/RS232/TCP(POE) RS232/RS485: default 115200 TCP(POE): 10/100M self-adaption 4.5 SG-HR-I5 4.5.1 SG-HR-I5 machine size Tab. 4.11SG-HR-I5Machine Size Parameters Name Boundary dimension Total weight Fixation type Shell material Shell color Guangdong Sygole Intelligent Technology Co.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.7 SG-HR-I5Machine Size Diagram (Unit mm) 4.5.2 SG-HR-I5 LED definition SG-HR-I5 reader has two LED indicator lights in total, which are specifically defined as follows: Tab. 4.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.8 Minimum Distance of Parallel Installation of SG-HR-I5 Readers The minimum distance of face-to-face installation of SG-HR-I5 readers should be more than or equal to 600 mm, as shown in Fig. 3.9. Fig. 3.9 Minimum Distance of Face-to-face Installation of SG-HR-I5 Readers 5.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd SG-HT-243 75 mm SG-HT-243M 50 mm SG-HT-244 50 mm SG-HT-263 85 mm SG-HT-263M 55 mm SG-HT-264 100 mm SG-HT-268 110 mm SG-HT-524M -- 6. Networking Application Sygole I series products support multiple communication modes. During networking application, the user may select a suitable communication mode according to the practical application conditions.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 6.2 POE communication mode When RFID system is directly connected to MES system or the field cannot be used due to economic problem, it is also a good choice to connect all RFID equipment together through TCP/IP. Specifically, the networking mode is as follows: 6.3 Serial communication mode All Sygole high frequency products support RS232 and RS485 communication modes.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd FCC NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.