High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Technical Manual Integrated RFID Reader The purpose of the practical manual is to provide the complete hardware appearance parameter, electric parameter, necessary schematic circuit diagram of the high frequency integrated reader and relevant notices for installation and operation.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Table of Contents 1. 2. 3. 4. 5. 6. Brief Introduction...................................................................................................................... 4 1.1 Brief introduction to the reader ........................................................................................... 4 1.2 Effective range of the manual ..............................................................
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 1. Brief Introduction 1.1 Brief introduction to the reader Sygole SG-HR-I1 reader is an integrated high frequency RFID read-write device, with the working frequency as 13.56MHz, and can meet ISO-15693 standard, and support RS-485, RS-232 and TCP (POE) communication. The shell thereof is made of high strength engineering plastics.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 2. Safety Instruction The product conforms to CE, UL, EMC and FCC significant safety specification. If you have any query upon the installation environment, please contact with our service representative. It is not allowed to modify or demount the product. If the user violates the requirement, the wireless equipment approval, the CE approval and the manufacturer certification will be canceled.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 3. Application planning for high frequency RFID reader 3.1 High frequency RFID application system 3.1.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.2 SG-HR-11Induction Plan View (as shown in shadow part) 1. Transmission window; 2. Sm main working field; 3. Sn second working field; 4. Sc critical field; 5.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.3 Front View for Right Installation of Tag Fig. 3.4 Front View for Wrong Installation of Tag Tag can enter the magnetic field area from any direction; in order to maximize the communication distance and obtain better quality, the tag should be installed maximally in parallel with the reader antenna.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.5 Tag Movement Direction Diagram Transmission window; Tag passes through area L×B; Tag of motion of the transponder; 3.1.4 Static and dynamic operations 3.1.4.1 Static mode According to 3.1.1, the magnetic field area of the reader is divided into the recommended working area, the working area and the critical area. The operation in the critical area may cause unexpected results to the data.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.6 Static Mode Operation Diagram Note: in metallic environment, both the reader and the tag may cause certain loss influence on the recognition distance, so it is necessary to prevent the metal from directly surrounding the reader or adopt anti-metal tag to increase the recognition distance. 3.1.4.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Tab. 3.1 Critical Distance (Sg), Operation Distance and Transmission window Length Corresponding to Reader Transmission Reader Model Operation Distance Critical Distance Sg window Length L SG- HR-I1 0~24 mm 30 mm (related to tag) 15 mm 3.2.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Note: the time mentioned in above table refers to the experimental test data read at a time and is only for your reference. However, a certain additional time brought by 2-3 repeated tag read-write operations of the reader may probably appear in the field application. In addition, such time is also closely related to the communication transmission mode and the speed.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.8 Demonstration of Thread Type Reader Installation in Metallic Environment Embedded installation into metal ---- it is necessary to reserve a free area large enough. Free area ---- it refers to the metal blank area around the reader which is embedded into metal. 1.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.10 Diagram for Annular Metal Framework Installation Mode If a single reader has been installed and surrounded by an enclosed metal framework, the metal framework may absorb the induced current generated by the magnetic field of the reader. If the metal framework is closer to the reader, the interference becomes greater, so such installation mode should be avoided in practical application.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd Fig. 3.12 Demonstration of Insertion of Non-metal between Reader and Metal Framework 3.3.3 Notice for tag installation Tag includes two types ---- anti-metal tag and non-anti-metal tag.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 3.3.4 Power supply and wiring requirments 3.3.4.1 Wiring requirements In industrial environment, correct ground connection is the main method for noise suppression and interference prevention, and the main interference of the equipment circuit is sourced from the unreasonable ground wire.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 4.2 Definition of communication interface SG-HR-I series products support RS485 and RS232 interfaces, wherein SG-HR-I5 products also support TCP (POE) interface, and the default interface is RS485 interface. Specifically, the interfaces are defined as follows: Tab. 4.2 RS485Interface (M12 Acoding 5pin male) Pin Definition No.
High Frequency Integrated RFID Reader Wireless radiation disturbance limit value Power port conduction interference limit value Static discharge interference i mmunity Certification Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd GB 9254-1998, GB/T 17626.3-1998 GB 9254-1998, GB/T 17626.3-1998 GB/T 17618-1998 4.2.1, GB/T17626.2-1998 CE 4.4 Electric parameters of the reader The electric parameters of SG-HR-I series readers are as shown in Tb. 4.6: Tab. 4.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 4.5 SG-HR-I1 4.5.1 SG-HR-I1 machine size Tab. 4.7S G-HR-I1 Machine Size Parameter Name Boundary dimension Total weight Fixation type Shell material Shell color Parameter φ18*92 mm <0.1KG Nut fixation Nickel plated brass + ABS Silver + black Fig. 4.1 G-HR-I1 Machine Size Diagram (Unit mm) 4.5.
High Frequency Integrated RFID Reader Light Power supply/communicati on indicator light Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd OFF: not electrified Normally-on green light: normal power supply Normally-on blue light: tag in the read area (automatic card-read status Green light flicker: in communication 4.5.3 Minimum distance between SG-HR-I1 readers The minimum distance of parallel installation of SG-HR-I1 readers should be more than or equal to 100 mm, as shown in Fig. 4.2.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd SG-HT-134 26 mm SG-HT-143 33 mm SG-HT-214M 7 mm SG-HT-243 30 mm SG-HT-243M 30 mm SG-HT-244 -- SG-HT-263 -- SG-HT-263M -- SG-HT-264 -- SG-HT-268 -- SG-HT-524M 16 mm 6. Networking Application Sygole I series products support multiple communication modes. During networking application, the user may select a suitable communication mode according to the practical application conditions.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd 6.2 Serial communication mode All Sygole high frequency products support RS232 and RS485 communication modes. Specifically, MODBUS RTU communication protocol can be used in serial communication. RS485 communication mode can be used for networking application, and in networking application, various readers need to work at different time.
High Frequency Integrated RFID Reader Operation Manual Guangdong Sygole Intelligent Technology Co.,Ltd FCC NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.