EDGE GSF LFID W/ AUTO TUNING Models: 074-11963 Installation / User Manual 890-00682 Version 02 Date: 10-04-21 REV02
All information, illustrations, photos, and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice.
Contents Chapter 1 Introduction...............................................................................................................................5 Contact information .....................................................................................................................5 General Safety Precautions and Usage.........................................................................................7 Telecommunication Advice.............................................................
NOTES 4 890-00682 EDGE GSF LFID W/ AUTO TUNING
1 Introduction Topics Covered in this Chapter ▪ ▪ ▪ ▪ ▪ ▪ ▪ Contact information General Safety Precautions and Usage Telecommunication Advice Terms of Use Inspecting Your Received System System Overview Guidelines for Installation Location Contact information Sales USA Automated Production Systems (AP/Cumberland) 1004 East Illinois St.
Chapter 1: Introduction Support USA Automated Production Systems (AP/Cumberland) Technical Support: 712-239-1011 Phone: 217-226-4449 International Phone: 217-226-4401 Fax: 217-226-3540 International Fax: 217-226-4420 E-mail : apsales@automatedproduction.com BRAZIL Contact your nearest GSI authorized representative. Consult the Brazilian representative list at: http://www.gsibrasil.ind.br/ -OR- http://www.gsibrasil.ind.
Chapter 1: Introduction General Safety Precautions and Usage Safety Symbols Warning. Read the following text carefully; it contains important information which, if ignored, may cause the controller to operate improperly High Voltage. Hazard of electrical shock. Read the message and follow the instructions carefully Direct current (DC) Alternating current (AC) Protective Earth Ground Terminal, Primarily used for protective earth terminals.
Chapter 1: Introduction Safety Messages Turn off the main electrical disconnect switch prior to servicing any of the boxes. Failure to do so might lead to serious injury or death. DANGER Always use extreme caution when measuring voltage or performing procedures that require a module to be powered on. Electrostatic Discharge Prevention When Manipulating a Printed Circuit Board (PCB) Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry.
Chapter 1: Introduction FCC non-interference disclaimer This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Terms of Use Read and follow all installation, operation, and maintenance information carefully before using the product.
Chapter 1: Introduction • Follow all installation and maintenance recommendations and consider all provided information regarding product specifications and limitations • Do not use the system if it does not operate correctly • The enclosures must be closed and locked at all times, particularly when operating the system • Use only specified replacement parts Inspecting Your Received System Inspecting your system and making sure you have received all expected parts helps avoid many hassles.
Chapter 1: Introduction Figure 1-1 EDGE GSF LFID W/ AUTO TUNING Guidelines for Installation Location Consider the environment, mounting recommendations, and clearance space to choose the ideal location for your system. Operating Environment • The ideal ambient temperature is between 20 °C and 25 °C (68 °F - 77 °F). The temperature should not go lower than 0 °C (32 °F) and should not exceed 40 °C (104 °F). • Ensure there is sufficient ventilation around the unit.
NOTES 12 890-00682 EDGE GSF LFID W/ AUTO TUNING
2 Installation Topics Covered in this Chapter ▪ Mounting the Antenna ▪ EDGE GSF LFID W/ AUTO TUNING Connections Mounting the Antenna The EDGE GSF LFID with Auto Tuning must be installed to the stall before connecting it to the EDGE GSF Feeder. What You Should Know These instructions only cover the installation of the EDGE GSF LFID with Auto Tuning to the GSF stalls. Refer to the GSF Stall assembly and installation manual for details on stall installation.
Chapter 2: Installation Figure 2-1 Mounting the antenna Item 01 02 03 04 05 06 07 08 09 10 14 Code GSF-0423 GSF-0763 GSF-1234 GSF-0413 GSF-1233 GSF-10021 SUS-BMC10030 SUS-FWM10 SUS-NLNM10 GSF-10027 Description ANTENNA PLATE ANTENNA UPPER PLATE ANTENNA REINFORCEMENT BRACKET ANTENNA PLATE SUPPORT BOTTOM ANTENNA REINFORCEMENT BRACKET ANTENNA HEX HEAD BOLT, M10X30 SUS304 8.8 GRADE GB/T5783-2000 WASHER, FLAT M10 SUS304 GB/T95 NYLOCK NUT, M10 SUS304 Grade 8,GB/T 889.1 SCREW,M8X1.
Chapter 2: Installation EDGE GSF LFID W/ AUTO TUNING Connections Connection output (5) is dedicated to the LFID Antenna. Connect the LFID Antenna cable to output (5). Connecting to Power Source The EDGE GSF LFID W/ AUTO TUNING power is supplied by the EDGE GSF. When the EDGE GSF is powered on, the EDGE GSF LFID W/ AUTO TUNING is running. The EDGE GSF comes with a power cord of 3 meters (9.8 feet). The EDGE GSF voltage is limited by the power cord provided with the model.
NOTES 16 890-00682 EDGE GSF LFID W/ AUTO TUNING
3 Maintenance Topics Covered in this Chapter ▪ Inspecting and Cleaning the EDGE GSF Inspecting and Cleaning the EDGE GSF Regularly inspecting and cleaning the EDGE GSF can prolong the life and keep the system functioning properly. Before You Begin Before servicing the system, disconnect the main voltage supply. CAUTION Do not pressure wash the EDGE GSF. WARNING WARNING Maintenance must only be performed by maintenance personnel and qualified service personnel. 1.
NOTES 18 890-00682 EDGE GSF LFID W/ AUTO TUNING
4 Troubleshooting Table 4-1 Troubleshooting Problem Possible Solutions Verify if the AC power cable plug is connected in the outlet Verify if the outlet breaker is not opened or correctly sized EDGE GSF does not power up Ensure that the AC power cable plug is not disconnected in the EDGE GSF plastic enclosure Verify if the outlet provides a voltage from 100-Vac to 240Vac Verify if the power led is green on the user interface If the problem persists, contact AP or GSI Electronics EDGE GSF LFID W/ AUTO
NOTES 20 890-00682 EDGE GSF LFID W/ AUTO TUNING
A Technical Specifications Table A-1 EDGE GSF LFID W/ AUTO TUNING — Safety Ratings INPUTS : Supply Input : 24VDC ± 10%, 1.92W Operating Temperature 0 to 40°C (32 to 104°F) Storage Temperature -20 to 50°C (-4 to 122°F) Environment Type Indoor use Pollution Degree 2 Installation Category 2 Altitude 2000 Meters Max. (6561 Ft.
Appendix A: Technical Specifications Table A-2 EDGE GSF LFID W/ AUTO TUNING — Functional Ratings (cont'd.
B Safety Characteristics and Certification Safety Characteristics The EDGE GSF is Safety Class I according to IEC classification and has been designed to meet the requirements of UL 61010-1 third edition, CAN/CSA-C22.2 nº 61010-1 third edition, EN 61010-1: 2010 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use). It is an Installation Category II intended for operation from a normal single phase or two phase(s) supply according to the power cord.
Appendix B: Safety Characteristics and Certification Table B-1 Emissions Test number 1 Test name Standard Standard level Radiated emissions CISPR 11 Group 1, class A FCC part 15, Subpart B Class A ICES-003 Class A EN61000-6-4 Class A ETSI EN 301 489-17 and ETSI EN 301 489-3, article 8.2 →EN 55032 Class A EMC characteristics - Immunity Standard The EDGE GSF has been designed to meet the requirements of the EMC Directive 2014/30/EU, FCC directives, Industry Canada directives.
Appendix B: Safety Characteristics and Certification Test methods, limits and performance achieved are shown below (requirement shown in brackets): Table B-2 Immunity Test number Test name Standard Standard level Radiated, radio-frequency, electromagnetic field immunity test IEC61000-4-3 : Modulation: ETSI EN 301 489-17 and ETSI EN 301 489-3, article 9.2→ EN61000-4-3 80% AM at 1kHz, 80MHz - 1GHz: 10V/m 1.4GHz-2 GHz: 3 V/m 2 2GHz-2.7GHz: 3 V/m 2.
Appendix B: Safety Characteristics and Certification Environment characteristics Parameter Condition Environment Location Inside Temperature Operating Humidity (Maximum Relative) Operating Value Operating 0 to 40°C (32 to 104°F) Storage -20 to +50°C (-4 to +122°F) 0 to 10 °C (32 to 50 °F) Non condensing 10 to 30 °C (50 to 86 °F) 95 % (± 3%) Non condensing 30 to 40 °C (86 to 104 °F) 95 % (± 3%) Non condensing Storage Non condensing 2000 Meters Max. (6561 Ft.
C EC Declaration of Conformity (In accordance with EN ISO 17050-1 2004) EC DECLARATION OF CONFORMITY (In accordance with EN ISO 17050-1 2004) We: Of: GSI Electronics Inc.
Appendix C: EC Declaration of Conformity Directive EMC Ref. No.
D Innovation, Science and Economic Development Canada Statement This device complies with RSS-210, and CAN ICES-003(*) / NMB-003(*) of Innovation, Science and Economic Development Canada Rules. This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard. Ce dispositif est conforme à la norme CNR-210, et CAN ICES-003(*) / NMB-003(*) d’ Innovation, Sciences et Développement économique Canada.
NOTES 30 890-00682 EDGE GSF LFID W/ AUTO TUNING
E FCC part 15 statement FCC Statement regarding the importation of radio frequency devices capable of causing harmful interference. GSI Electronics Inc. develops, manufactures and distributes innovative technological products for the agricultural industry. Our unique expertise allows us to offer accurate, simple and diverse electronic, data processing and mechanical solutions for improving agricultural production. The EDGE GSF has a RFID device at 134.2 kHz: EDGE GSF LFID W/ AUTO TUNING.
NOTES 32 890-00682 EDGE GSF LFID W/ AUTO TUNING
F FCC RF Exposure Statement regarding the importation of radio frequency devices capable of causing radiation exposure. GSI Electronics Inc. develops, manufactures and distributes innovative technological products for the agricultural industry. Our unique expertise allows us to offer accurate, simple and diverse electronic, data processing and mechanical solutions for improving agricultural production. The EDGE GSF has a RFID device at 134.2 kHz: EDGE GSF LFID W/ AUTO TUNING.
NOTES 34 890-00682 EDGE GSF LFID W/ AUTO TUNING
G FDA declaration Statement regarding the importation of devices and public health hazard directives from FDA (U.S. Food and Drug Administration) GSI Electronics Inc. develops, manufactures and distributes innovative technological products for the agricultural industry. Our unique expertise allows us to offer accurate, simple and diverse electronic, data processing and mechanical solutions for improving agricultural production. GSI Electronics’ controllers are shipping under 9032.89.60.
NOTES 36 890-00682 EDGE GSF LFID W/ AUTO TUNING
H Reduction of Hazardous Substances REACH directive The REACH directive addresses the production and use of chemical substances, and their potential impacts on both human health and the environment. On June 1, 2007, the European Commission promulgated new legislation that covers the registration, evaluation, authorization and restriction of chemical within the European Union community.
NOTES 38 890-00682 EDGE GSF LFID W/ AUTO TUNING
I Disposal and Recycling Information North America : Canada As the concern for the volume of electronic waste grows, a number of Provinces in Canada have passed regulations since 2006 to divert electronics waste from the landfills and to protect the environment. These waste diversion regulations require manufacturers of covered electronic devices to participate in approved electronic product stewardship programs.
Appendix I: Disposal and Recycling Information • Public system— contact your municipality or the nearest collection site to dispose of Electrical and electronic Equipment waste • Private system— For a Return Material Authorization for Disposal of Waste Equipment, contact customer support at 1-877-926-2777 or by e-mail at mtl_techsupport@agcocorp.
J California Proposition 65 California Proposition 65 - Statement regarding the importation of devices and public health hazard directives from The Office of Environmental Health Hazard Assessment (OEHHA) In 1986, California voters approved Proposition 65, an initiative to address their growing concerns about exposure to toxic chemicals. That initiative is officially known as the Safe Drinking Water and Toxic Enforcement Act of 1986.
NOTES 42 890-00682 EDGE GSF LFID W/ AUTO TUNING
K Product material composition EDGE GSF Antenna Material Weight Lbs Grams Percentage of the product weight (%) Packaging material Plastic material Electronic Circuits Metal 890-00682 EDGE GSF LFID W/ AUTO TUNING 43
NOTES 44 890-00682 EDGE GSF LFID W/ AUTO TUNING
L Packaging Characteristics The following directives were followed during the packaging process 2015/863/EU The RoHS 3 directive 2012/19/EU The WEEE 2 directive 1907/2006/EU The REACH regulation 2006/66/EC The battery directive 94/62/EC Packaging and packaging waste directive 97/129/EC Packaging material identification directive The packaging is only in cardboard to respect international standards about environment standards: EN 13428 Packaging - Requirements specific to manufacturing and com
NOTES 46 890-00682 EDGE GSF LFID W/ AUTO TUNING
M EDGE GSF LFID with Auto Tuning - End-of-Life Disassembly This disassembly and recycling guidance provides general guidance for the disassembly of the referenced product to remove components and materials requiring selective treatment, as defined by EU directive 2002/96/EC and, Waste Electrical and Electronic Equipment (WEEE). Models and Descriptions This document provides disassembly instructions for the product listed in the next table.
Appendix M: EDGE GSF LFID with Auto Tuning - End-of-Life Disassembly Disassembly of EDGE GSF LFID with Auto Tuning 4 2 3 6 1 5 7 8 10 Item number 48 9 Description Item number Description 1 PLASTIC ANTENNA ENCLOSURE 6 PCB SCREWS 2 SCREW,M8-1.
Appendix M: EDGE GSF LFID with Auto Tuning - End-of-Life Disassembly Items Requiring Selective Treatment Items in the product that are classified as requiring selective treatment are provided in the following table. Item description Notes Quantity of items included in the product 1 Printed Circuit Boards (PCB) or Printed Circuit Assemblies (PCA) With a surface greater than 10 square cm Batteries All types including standard alkaline and lithium coin or button style batteries.
Appendix M: EDGE GSF LFID with Auto Tuning - End-of-Life Disassembly Item description Notes Quantity of items included in the product Components, parts and materials containing refractory ceramic fibres none Components, parts and materials containing radioactive substances none Components, parts and materials containing chlorofluorocarbons (CFC), hydrochlorofluorocarbons (HCFC), hydrofluorocarbons (HFC), hydrocarbons (HC) none 1All Location plastics used in this product are RoHS compliant and do
Limited Warranty - Protein Products The GSI Group, LLC. (“GSI”) warrants products which it manufactures, to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months from the date of purchase (or, if shipped by vessel, 14 months from the date of arrival at the port of discharge).
This equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made. 1004 E. Illinois St. Assumption, IL 62510-0020 Phone: 1-217-226-4421 Fax: 1-217-226-4420 www.automatedproduction.