FCC ID : U88GSTR-TRIT-SPR ATTACHMENT E. - USER MANUAL - HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR INFORMATION TO USER : NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
FCC ID : U88GSTR-TRIT-SPR - INDEX 1. SUMMARY .................................................................................................................4 2. SYSTEM CONFIGURATION .....................................................................................6 2.1 Tri-band repeater service network configuration ................................................6 2.2 System Design and Operation......................................................................................8 3.
FCC ID : U88GSTR-TRIT-SPR 1. Summary Tri-band In-building repeater is located in blanket / shadow area of insider of building to transmit Sprint/Nextel CDMA (PCS), iDEN800MHz, iDEN900MHz BTS signal simultaneously. Characteristics (CDMA) CDMA (PCS) Band: 80dB Gain with +24dBm maximum output power iDEN Band: 65dB Gain with +25dBmmaximum output power. Bandwidth: Entire 1900MHz CDMA (PCS) frequency A Block to G Block (65MHz). Bandwidth selection functions per user’s situation.
FCC ID : U88GSTR-TRIT-SPR Characteristics (Tri-Band) Basically system box is two combination types of iDEN and CDMA technologies. Functional modules are classified as below. - 6-Plex and Hybrid Multiplex Cavity Filter to combine HyCDMA (PCS), iDEN 800MHz, iDEN 900MHz, Duplex input/output signal. - LNA(Low Noise Amplifier), - Gain Block to transmit output signal to PAM (Power Amplifier Module). - Donor LNA, Server LNA Module, which include Divider / combiner for IF Module interface.
FCC ID : U88GSTR-TRIT-SPR 2. System Configuration 2.1 Tri-band repeater service network configuration The system’s operation range is from A Block to G Block (Total: 65MHz) and the system features - to set up 20MHz using 5MHz, 10MHz, 15MHz and contiguous ‘Block’ - to set up 3 non-contiguous 5MHz Block - to set up Sub Block by 5MHz with 10MHz, 15MHz Block - Remote control through GUI This system is to provide iDEN800MHz and 900MHz simultaneously. Available band selection a.
FCC ID : U88GSTR-TRIT-SPR Tri-band In-building Repeater Service organization HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 7 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR 2.2 System Design and Operation 2.2.1 System design NO. PART NO. PART 1 SERVICE CAVITY MODULE 12 iDEN FWD LAN MODULE 2 DONOR CAVITY MODULE 13 iDEN NMS& I’O BOARD MODULE 3 5M IF CONVERTER MODULE 14 US PCS NMS& I’O BOARD MODULE 4 18M IF CONVERTER MODULE 15 US PCS WAVE MONITORING MODULE 5 7M IF CONVERTER MODULE 16 US PCS FWD PAM 6 iDEN RVS LAN MODULE 17 US PCS RVS PAM HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
FCC ID : U88GSTR-TRIT-SPR 7 US PCS RVS LAN MODULE 18 iDEN WAVE MONITORING MODULE 8 20M IF CONVERTER MODULE 19 iDEN RVS PAM 9 15M IF CONVERTER MODULE 20 iDEN FWD PAM 10 10M IF CONVERTER MODULE 21 PSU MODULE 11 US PCS FWD LAN MODULE 22 HUB Tri-band In-building Repeater internal design NO. PORT NO.
FCC ID : U88GSTR-TRIT-SPR iDEN 25dBm PORT design 2.2.2 Downlink Path Tri-band In-building RF Repeater operates CDMA (PCS) and iDEN800MHz, iDEN900MHz. RF Module shares the modules used for CDMA (PCS) equipment and iDEN equipment and have differences in the configures of Donor ANT and Server ANT Port. Tri-band In-building RF Repeater has separate 2 Donor ANT Port for aiming each BTS. Server Port for indoor is possible to one port.
FCC ID : U88GSTR-TRIT-SPR Tri-band In-building Repeater Uplink Block Diagram 2.2.4 Adjustable Band Edge functional circuit configuration In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is input via Donor ANT Outdoor. The most worried signal among them is Paging Signal. Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max. -15dBm, is to be inputted into Donor ANT.
FCC ID : U88GSTR-TRIT-SPR Achieving additional Roll Off via Adjust Band Edge 2.2.5 US PCS Frequency Selection A 1930 D 1945 B 1950 E 1965 F 1970 C 1975 G 1990 1995 f (MHz) 1915 f (MHz) < Forward Band Structure > A 1850 D 1865 B 1870 E 1885 F 1890 C 1895 G 1910 < Reverse Band Structure > PCS Band Structure Setup of CDMA Block is formed by Switch and SAW Filter.
FCC ID : U88GSTR-TRIT-SPR Configure of IF Converter for CDMA Block Configure for one 5MHz Block Configure for one 15MHz Block Configure for one 10MHz Block Configure for continuous 20MHz Block HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 13 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR Configure of separated 20MHz Configure of 3 separated 5MHz 3. Electric Material and Specifications 3.
FCC ID : U88GSTR-TRIT-SPR Output iDEN +25dBm / 316mW Composite CDMA (PCS) +24dBm / 250mW Power (ANT Port) +22dBm / 158mW Per Single Band 3.2 System Material & Mechanical Specifications Item Specification Remark RF Connector N-Type Female Donor & Server ANT Port Power AC MS3102A-10SL (3Pin) MIL-C-5015 Type Connector DC SCK-16-2P (2Pin) Circular Type AC Supply AC 120V 60Hz 3.0A Out Dimension 16.7*23*6.77 Inch Net Weight 29.
FCC ID : U88GSTR-TRIT-SPR Spurious F0±885kHz <-45dBc ∆marker: 29dB Emission F0±1.98MHz <-50dBc ∆marker: 34dB Out Band Spurious Emission <-13dBm RBW: 30MHz @ CHOFFSET 25kHz > 50dBc Adjacent @ CHOFFSET 50kHz > 55dBc Degradation of 3dB Channel @ CHOFFSET 500kHz > 55dBc for eight (8) iDEN @ CHOFFSET 1MHz > 55dBc carriers @ CHOFFSET 2MHz > 55dBc Power Adjust @ 869MHz 868.8MHz / 868.6MHz Band Edge @ 940MHz 939.8MHz/ 939.6MHz Flatness <±1.25dB Return Loss / VSWR > 14dB /<1.
FCC ID : U88GSTR-TRIT-SPR • To limit output power as far as default range • Set up via GUI • Automatic Gain decrement when output power of repeater is higher than ALC Auto Limit Control default level • Automatic Gain recovery when output power of repeater is reduced.
FCC ID : U88GSTR-TRIT-SPR • LED displays power and operation status on front side of repeater system. LED Display • DL input and output signal level is verified by LED bar. 4. SET UP 4.1 System Set up 4.1.1 Constitution (based on 1 SET) Parameter Item Quantity Major accessory TRI Case 1 EA Additional components Main power input Cable 1 EA Mountable Bracket 1 EA Fixable Screw 1 SET Manual 1 EA User Manual 4.1.
FCC ID : U88GSTR-TRIT-SPR . Tri-band In-building Repeater Case mounts HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 19 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR Tri-band In-building Repeater Case installation 4.1.3 System set up 1) Once aforementioned process is done, open for service get ready. 2) For grounding, there is a grounding terminal in main power supply side and the grounding terminal on a site and unit should be connected same. 3) System installation work is basically performed more than two people and should be careful for unexpected accident. 4.1.4 Open for service 1) Check points before open a.
FCC ID : U88GSTR-TRIT-SPR ⑤ CDMA: Number of LED bar on front side of repeater will show input signal level. Less than -56dBm: LED 1bar -56dBm~-48dBm: LED 2bars -48dBm~-39dBm: LED 3 bars -39dBm~-31dBm: LED 4 bars -31dBm~-23dBm: LED 5 bars Number of LED bar in output power side will show output power signal level Less than +6dBm: LED 1bar +6dBm~+12dBm: LED 2 bars +12dBm~+15dBm: LED 3 bars +15dBm~+18dBm: LED 4 bars +18dBm~+22dBm: LED 5 bars Tri-band In-building Repeater front LED b.
FCC ID : U88GSTR-TRIT-SPR 4.2 Troubleshooting In case, abnormal operation is detected, user should check abnormal parts via remote accessible function or field debug, then conduct repair after turn it off. 4.2.1 Necessary Testing and Measuring equipment a. RF Power Meter: 10Watt Max, 50ohm b. Signal Generator: 3GHz c. Spectrum Analyzer: 3GHz d. Multi Meter 4.2.2 Notice a. Trouble shooting should be performed with drastic knowledge basis. b. Unsure parts should not be disassembled. c.
FCC ID : U88GSTR-TRIT-SPR 5. WEB USER INTERFACE 5.1 Common set up (PCS, IDEN) 5.1.1 IP Address verification and Explorer setting (1) Start->Control Panel->Network Connections (2) Double-click Local Area Connections at LAN or High Speed internet (3) Click Internet Protocol (TCP/IP) at General tap and click Properties. (4) Apply automatic IP address assignment at local connection (5) Verify assigned IP address at local connection. (Unless IP address is not assigned, please click repair.) TECHNOLOGIES CO.
FCC ID : U88GSTR-TRIT-SPR 5.1.2 Explorer option setting - Proceed step by step as indicated in below. All files and records should be removed. - Set up mode will be displayed after (2) click. - Please proceed along following set up mode screen shot. 5.2 PCS Web UI 5.2.1 Web UI connection - Input desirable IP address. - Default Use Name and Password for Web UI is ‘admin’. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
FCC ID : U88GSTR-TRIT-SPR 5.2.1 Link menu - Following screen shot is located left-top side of main menu and those are linked to relative window. 5.2.2 Web UI control 5.2.2.1 Status - Currently setting level check at this menu tap. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 25 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR 5.2.2.2 RF Configuration - Setting level can be changed at this menu tap. - (1) Level change - (2) Click Apply button 5.2.2.3 Alarm Configuration - (1) On/Off function for entire alarm report HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 26 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR - (2) Alarm status - (3) On/Off function for individual alarm category - (4) Alarm SNMP Mapping - User may set and change its level per it field condition and click apply button. 5.2.2.4 Communication Configuration - This provides all necessary information related to network - To provide relative information about DHCP and modem HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
FCC ID : U88GSTR-TRIT-SPR 5.2.2.5 User Management - Add and Remove user, Assigning accessibility - (1) User Registration: Click Register after input required information - (2) User Removal: Click Delete upon click of user name you wish to remove. - (3) Super User: Accessible to all kinds of information path Read/Write: Accessible to all kinds of information path except for User management path. Read: Checking status only. No control 5.2.2.6 Logs - All users’ access record will be saved as a log. 5.2.2.
FCC ID : U88GSTR-TRIT-SPR - Set up e-mail address the place you wish to receive alarm. 5.2.2.8 Troubleshooting Following is a trouble shooting table, which is frequently occurred to repeater and treatment me thod. 5.2.2.9 Remote Software Upgrade - Upload repeater operation program. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 29 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR 5.2.2.10 System Reset - Reset repeater. 5.3 IDEN Web UI 5.3.1 Web UI connection - Input IP address, want to reach. - Default setting User Name and Password for Web UI is ‘admin’. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 30 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR 5.3.1.2 Link menu Following screen shot is located left side of main menu and those are linked to relative window. 5.3.2 Web UI Control 5.3.2.1 Status - Currently setting level check at this menu tap. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 31 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR 5.3.2.2 RF Configuration - Setting level can be changed at this menu tap. - (1) Level change - (2) Click Apply button 5.3.2.3 Alarm Configuration HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 32 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR - (1) On/Off function for entire alarm report - (2) Alarm status - (3) On/Off function for individual alarm category - (4) Alarm SNMP Mapping - User may set and change its level per it field condition and click apply button. 5.3.2.4 Communication Configuration - This provides all necessary information related to network - To provide relative information about DHCP and modem HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
FCC ID : U88GSTR-TRIT-SPR 5.3.2.5 User Management - Add and Remove user, Assigning accessibility (1) User Registration: Click Register after input required information (2) User Removal: Click Delete upon click of user name you wish to remove. (3) Super User: Accessible to all kinds of information path Read/Write: Accessible to all kinds of information path except for User management path. Read: Checking status only. No control 5.3.2.6 Logs HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
FCC ID : U88GSTR-TRIT-SPR - All users’ access record will be saved as a log. 5.3.2.7 Sub System/Mailing List - Set up e-mail address, the place you wish to receive alarm 5.3.2.8. Troubleshooting - Following is a trouble shooting table, which is frequently occurred to repeater and treatment me thod. HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 35 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR 5.3.2.9 Remote Software Upgrade - Upload repeater operation program HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 36 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.
FCC ID : U88GSTR-TRIT-SPR 5.3.2.10 System Reset - Reset repeater HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD. 37 SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr Report No.