FCC ID : U88GSTR-825DC-SPR ATTACHMENT E.
FCC ID : U88GSTR-825DC-SPR INFORMATION TO USER : NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
FCC ID : U88GSTR-825DC-SPR - INDEX 1. SUMMARY .................................................................................................................4 2. SYSTEM STRUCTURE...............................................................................................5 2.1 Network structure for iDEN 25dBm RF Repeater ............................................................................................. 5 2.2 System Design and Operation .........................................................
FCC ID : U88GSTR-825DC-SPR 1. SUMMARY iDEN repeater is located in blanket / shadow area of insider of building to transmit iDEN800MHz, iDEN900MHz BTS signal simultaneously. There are two types of RF Repeater for iDEN band as each 15dBm, and 25dBm output power in system 65dB Gain, and 30dBm output power in system 80dB Gain. This User Manual is the Repeater having 65dBGain / +25dBm output power.
FCC ID : U88GSTR-825DC-SPR 2. SYSTEM STRUCTURE 2.1 Network structure for iDEN 25dBm RF Repeater Below picture shows a Network structure for iDEN In-building RF Repeater in a real site. Donor ANT takes a position on the direction to BTS which be linked, and Server ANT is available to be located in designated area for service by using RF cable deployments and dividers as blow. One thing that we consider is Path losses between Repeater port and ANT in case of dividing by dividers and RF cables.
FCC ID : U88GSTR-825DC-SPR 2.2 System Design and Operation 2.2.1 System design NO. PART NO.
FCC ID : U88GSTR-825DC-SPR iDEN 25dBm internal design NO. PORT NO. PORT ① SERVICE ANT PORT ⑤ AC POWER PORT ② SERVICE ANT TERM ⑥ DC POWER PORT ③ DONOR ANT PORT ⑦ MONITOR PORT ④ DONOR ANT TERM ⑧ ETHERNET PORT iDEN 25dBm PORT design 2.2.2 Downlink Path There are four (4) parts of downlink Block in iDEN In-building RF Repeater.
FCC ID : U88GSTR-825DC-SPR - If Converter part having several bands of SAW Filter paths to adjust Band Edge of high frequency as 200KHz and 400KHz each. In case of 800MHz band, extra Switching Filters equipped to individually select 18MHz and 7MHz - Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to adjust desirable output power of Repeater Downlink frequency contains lots of signals such as Paging signal, DCS etc through Donor ANT.
FCC ID : U88GSTR-825DC-SPR of Donor/Server - LNA Part of two(2) paths for processing 800MHz and 900MHz signals - 800MHz IF Converter part and 900MHz IF Converter part of 5MHz band having Switching filter parts for selecting each 18MHz and 7MHz.
FCC ID : U88GSTR-825DC-SPR Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max. -15dBm, is to be inputted into Donor ANT. Among this two kind of Paging Signal Band, 929MHz~932MHz bandwidth is possible for sufficient Rejection via SAW Filter, But 940MHz~941MHz is difficult to gain big decreasing volume even if use SAW Filter because Band Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz Downlink.
FCC ID : U88GSTR-825DC-SPR 3. SPECIFICATIONS 3.1 System specifications Characteristic Specification 800MHz Forward Frequency Range 900MHz Reverse 800MHz 900MHz 18 MHz BAND 851~869 MHz 17.8 MHz BAND 851~868.8 MHz 17.6 MHz BAND 851~868.6MHz 7 MHz BAND 862~869 MHz 6.8 MHz BAND 862~868.8 MHz 6.6 MHz BAND 862~868.6MHz 5 MHz BAND 935~940MHz 4.8 MHz BAND 935~939.8MHz 4.6 MHz BAND 935~939.
FCC ID : U88GSTR-825DC-SPR Pass Band Ripple 2.5dB(±1.25dB) Maximum Output Power 316.
FCC ID : U88GSTR-825DC-SPR • To add or subtract Attenuation level referring to AGC Power Limit level. • To limit output power as far as default range • Set up via GUI ALC Auto Limit Control • Automatic Gain decrement when output power of repeater is higher than default level • Automatic Gain recovery when output power of repeater is reduced.
FCC ID : U88GSTR-825DC-SPR • Reporting VSWR Alarm and Shutdown when the rate is 3:1 • Automatic Recovery Algorithm conversion after Shutdown status IP address report via E-mail • When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address, reports to operator.
FCC ID : U88GSTR-825DC-SPR 4. SET UP 4.1 System Set up 4.1.1 Constitution (based on 1 SET) Parameter Item Quantity Major accessory iDEN 25dBm repeater 1 EA Additional components Main power input Cable 1 EA Mountable Bracket 1 EA Fixable Screw 1 SET Manual 1 EA User Manual 4.1.2 Notice 1 ) System Power check : Major electricity is A C 1 1 0 V, therefore please input electricity after power verification.
FCC ID : U88GSTR-825DC-SPR
FCC ID : U88GSTR-825DC-SPR Hole sizes of iDEN In-building RF Repeater 4.1.3 System set up 1) Once aforementioned process is done, open for service get ready. 2) For grounding, there is a grounding terminal in main power supply side and the grounding terminal on a site and unit should be connected same. 3) System installation work is basically performed more than two people and should be careful for unexpected accident. 4.1.4 Open for service 1) Check points before open a.
FCC ID : U88GSTR-825DC-SPR a. Check by external LED ① RUN: Green light ON (Off: Green light off) ② ALARM: Green light in normal status, Red light in alarming ③ SHUT DOWN: Green light in normal status, Red light in Shutdown ④ iDEN Number of LED bar on front side of repeater will show input signal level. -43 dBm~38dBm: LED 1bar -37dBm~-33dBm: LED 2 bars -32dBm~-28dBm: LED 3 bars -27dBm~-23dBm: LED 4 bars Up than -22dBm: LED 5 bars Number of LED bar in output power side will show output power signal level.
FCC ID : U88GSTR-825DC-SPR Spectrum Analyzer. - Output power generation status, system spurious emission characteristics. d. Verification of signal quality and strength in service area User should verify signal strength and quality of in-service coverage area by using cell phone or other terminal. e. Verification of upper-level NMS operation status 4.
FCC ID : U88GSTR-825DC-SPR (5) Verify assigned IP address at local connection. (Unless IP address is not assigned, please click repair.) 5.1.2 Explorer option setting - Proceed step by step as indicated in below. All files and records should be removed. - Set up mode will be displayed after (2) click. - Please proceed along following set up mode screen shot.
FCC ID : U88GSTR-825DC-SPR 5.2 Web UI 5.2.1 Web UI connection - Input desirable IP address. - Default Use Name and Password for Web UI is ‘admin’. 5.2.
FCC ID : U88GSTR-825DC-SPR window. 5.3 Web UI control 5.3.1 Status - Currently setting level check at this menu tap. 5.3.2 RF Configuration - Setting level can be changed at this menu tap.
FCC ID : U88GSTR-825DC-SPR 5.3.3 Alarm Configuration - (1) On/Off function for entire alarm report - (2) Alarm status - (3) On/Off function for individual alarm category - (4) Alarm SNMP Mapping - User may set and change its level per it field condition and click apply button. 5.3.
FCC ID : U88GSTR-825DC-SPR - This provides all necessary information related to network - To provide relative information about DHCP and modem 5.3.5 User Management - Add and Remove user, Assigning accessibility - (1) User Registration: Click Register after input required information - (2) User Removal: Click Delete upon click of user name you wish to remove.
FCC ID : U88GSTR-825DC-SPR 5.3.6 Logs - All users’ access record will be saved as a log. 5.3.7 Sub System/Mailing List - Set up e-mail address the place you wish to receive alarm. 5.3.8. Troubleshooting Following is a trouble shooting table, which is frequently occurred to repeater and treatment me thod.
FCC ID : U88GSTR-825DC-SPR 5.3.9 Remote Software Upgrade - Upload repeater operation program. 5.3.10 System Reset - Reset repeater.