Measurement Guide

Cellulose
Insulation
BLOW-IN
OR
SPRAY-APPLIED
ATTIC CARD
25lbs (11.3kg)
SANCTUARY
®
R-Value at 75° F
Mean Temp.
Minimum Thickness (inches)
Espesor minimo (en pulgadas)
Net Coverage (no adjustment for framing)
Cobertura neta (sin compesación para la estructura)
Initial Installed Thickness
Espesor inicial instalado
Settled Thickness
Espesor asentado
Maximum Sq. Ft. per Bag
Pies cuadrados máximos por bolsa
Minimum Bags per 1,000 Sq. Ft.
Cantidad minima de bolsas por 1,000 pies cuadrados
Minimum Weight per Sq. Ft.
Peso minimo por pie cuadrado
Net Coverage (adjusted for 2" x 6" framing on 16" centers)
Cobertura neta (con compensación para una estructura de 2" x 6" en centros de 16")
Maximum Sq. Ft. per Bag
Pies cuadrados máximos por bolsa
Minimum Bags per 1,000 Sq. Ft.
Cantidad minima de bolsas por 1,000 pies cuadrados
THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 25 LBS USING A
VOLUMATIC III, 3RD GEAR AND 8" GATE. THE CHART IS BASED ON SETTLED THICKNESS AND IS FOR
ESTIMATING PURPOSES ONLY. DO NOT EXCEED MAXIMUM SQUARE FEET COVERAGE PER BAG. THE
APPLICATOR MUST INSTALL BOTH THE MINIMUM NUMBER OF BAGS PER 1000 SQ. FT. AND THE
MINIMUM INSTALLED THICKNESS TO ENSURE THE STATED R-VALUE HAS BEEN REACHED. FAILURE
TO MEET BOTH THESE REQUIREMENTS MAY PREVENT THE APPLICAITON OF SPECIFIED R-VALUE.
JOB CONDITIONS, APPLICATION TECHNIQUES, EQUIPMENT AND SETTINGS CAN INFLUENCE ACTUAL
COVERAGE. MINIMUM NET WEIGHT IS 23.75 LBS.
THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 25.0 LBS USING A VOLUMATIC III, 3rd
GEAR AND 8" GATE. THE CHART IS BASED ON SETTLED THICKNESS AND IS FOR ESTIMATING PURPOSES ONLY.
DO NOT EXCEED MAXIMUM SQUARE FEET COVERAGE PER BAG. THE APPLICATOR MUST INSTALL BOTH THE
MINIMUM NUMBER OF BAGS PER 1000 SQ. FT. AND THE MINIMUM INSTALLED THICKNESS TO ENSURE THE
STATED R-VALUE HAS BEEN REACHED. FAILURE TO MEET BOTH THESE REQUIREMENTS MAY PREVENT THE
APPLICATION OF SPECIFIED R-VALUE. THE INSTALLED MOISTURE CONTENT MUST BE BETWEEN 16% AND 22%
IN ATTIC APPLICATIONS. JOB CONDITIONS, APPLICATION TECHNIQUES, EQUIPMENT, AND SETTINGS CAN
INFLUENCE ACTUAL COVERAGE. MINIMUM NET WEIGHT IS 23.75 LBS.
11
13
19
22
26
30
32
38
40
44
48
49
50
60
3.3
3.9
5.7
6.6
7.7
8.9
9.5
11.2
11.8
12.9
14.0
14.3
14.6
17.3
3.0
3.6
5.3
6.1
7.2
8.3
8.8
10.4
10.9
12.0
13.0
13.3
13.5
16.1
78.6
65.8
44.2
38.0
31.2
25.9
23.8
19.0
17.7
15.7
14.1
13.8
13.5
10.8
0.32
0.38
0.57
0.66
0.80
0.97
1.05
1.32
1.41
1.59
1.77
1.81
1.86
2.31
86.7
72.6
48.8
41.2
33.4
27.4
25.2
19.9
18.6
16.5
14.6
14.2
14.0
11.1
12.7
15.2
22.6
26.3
32.1
38.6
42.0
52.6
56.5
63.5
70.8
72.6
74.3
92.5
11.5
13.8
20.5
24.2
30.0
36.5
39.7
50.1
53.8
60.8
68.5
70.2
71.4
89.8
ATTIC COVERAGE CHART – LOOSE-FILL AND STABILIZED APPLICATIONS
LOOSE-FILL APPLICATIONS STABILIZED APPLICATIONS
Tabla de Cobertura de Ático - Aplicaciónes de Relleno Suelto y Aplicaciónes Estabilizadas
Wilkes-Barre, PA 18702
Debert, Nova Scotia
Norfolk, NE 68701
Mesa, AZ 85212
Salt Lake City, UT 84119
Tampa, FL 33605
Waco, TX 76704
Manufactured by
US Greenfiber, LLC
Toll-Free 800-228-0024
www.greenfiber.com
Greenfiber is a registered
trademark of US Greenfiber, LLC.
All rights reserved.
© 2020 US Greenfiber, LLC.
All rights reserved.
US Greenfiber, LLC
5500 77 Center Drive, Suite 100
Charlotte, NC 28217
Made in USA
This coverage chart is based on the Volumatic III, 2nd gear, 6" gate. The installed moisture content must be
between 25% and 35% as measured by a hand held moisture meter. Do not cover the insulation until the
insulation moisture content, measured and documented after a minimum period of 24 hrs from the time of
installation, reaches 25% or less in accordance with Greenfiber's Wallspray Manual. Install dry dense pack
Sanctuary insulation in all exterior wall sections where added vapor impediments, such as cabinets,
mirrors, tubs, and shower enclosures are located. If unsure where impediments are located, dry dense
pack the entire exterior wall section(s). Non-standard or unusual wall configurations (i.e., other than 2x4
and 2x6 walls) can affect thermal and sound properties and require special installation considerations.
These types of designs should be analyzed and, if necessary, tested prior to plan review. Contact Greenfiber
technical representative for applications or framing that is not included on these charts.
Spray-Applied Sidwall Applications (2.75 pcf minimum installed density)
Framing
Estructura
Maximum Coverage per Bag
(Adjusted for Framing)
Cobertura máxima por bolsa (con compensación para la estructura)
16
16 pulgadas o.c. pie2/bolsa
inch o.c.
ft
2
/Bag
24 pulgadas o.c. pie2/bolsa
24 inch o.c.
ft
2
/Bag
2 x 4
2 x 6
13
21
3.5
5.5
0.79
1.24
35.0
22.3
33.8
21.6
Dry Dense-Pack Sidewall & Floor Applications
(3.5 pcf minimum installed density)
Thermal
Resistance
(R value)
Resistencia térmica
(R)
Framing
Estructura
Maximum Coverage per Bag
(Adjusted for Framing)
Cobertura máxima por bolsa (con compensación para la estructura)
16
16 pulgadas o.c. pie2/bolsa
inch o.c.
ft
2
/Bag
24 pulgadas o.c. pie2/bolsa
24 inch o.c.
ft
2
/Bag
This coverage chart is for dry applications only and is based on the Krendl KS200, with material applied dry.
2 x 4
2 x 6
2 x 8
13
21
28
3.5
5.5
7.5
1.02
1.60
2.19
27.0
17.2
12.6
26.1
16.6
12.1
SIDEWALL & FLOOR COVERAGE CHART
DENSE-PACK APPLICATION
SANCTUARY
®
Tabla de Cobertura de Piso y Pared Lateral -Aplicaciónes de Paquete Denso
Tabla de Cobertura de Pared Lateral - Aplicaciónes Aplicadas por Spray
PM-6.3328 Rev C 05/20
Valor de resistencia
termica (valor R)
at 75 F de
temperature media
SIDEWALL COVERAGE CHART
SPRAY APPLIED APPLICATIONS
SANCTUARY
®
Thermal
Resistance
(R value)
Resistencia térmica
(R)
Installed
Thickness
(Inches)
Espesor instalado
(pulgadas)
This insulation has been installed in conformance with
the above recommendations, to provide a value of
R- using bags of this insulation
to cover square feet of area.
Minimum Wt
Per Square foot
lb/ft
2
lb/ft
2
Peso mínimo por
pie cuadrado
Installed
Thickness
(Inches)
Espesor instalado
(pulgadas)
Minimum Wt
Per Square foot
lb/ft
2
lb/ft
2
Peso mínimo por
pie cuadrado
UL Classified.
See complete marking on back of packaging
Greenfiber
®
provides outstanding thermal
performance, fire-resistance and sound control.
Consisting of up to 85% recycled content, Greenfiber
®
Insulation is specially treated for flame resistance.
R-value means resistance to heat flow - the higher the
R-value, the greater the insulation power.
Builder’s Signature
Company Name
Date
Applicator’s Signature
Company Name
Date

Summary of content (1 pages)