Full Product Manual

1
Determine the Target R-Value
First, determine the R-Value recommended
for your region. R-Value indicates
insulating power or thermal resistance
(adjacent chart). Once you know your
target R-Value, refer to the Greenfiber
®
Insulation coverage chart (on Greenfiber
®
Insulation product bag or see the charts
on the next page). These charts will
indicate, for a 1,000-square-foot area, how
many bags of Greenfiber
®
Insulation you
will need to purchase and how many
inches of coverage you will need.
To calculate exactly how much
Greenfiber
®
Insulation you need for a
specific number of square feet, you can
use the following table provided by the
U.S. Department of Energy Insulation
Recommendations for Existing Houses.*
DO-IT YOURSELF ATTIC INSTALLATION INSTRUCTIONS
Zone 1 includes
Hawaii, Guam,
Puerto Rico, and
the Virgin Islands
Wall Insulation: Whenever exterior
siding is removed on an UNINSULATED
wood-frame wall:
Drill holes in the sheathing and blow
insulation into the empty wall cavity
before installing the new siding, and:
Zones 3-4: Add R5 insulative wall
sheathing beneath the new siding
Zones 5-8: Add R5 to R6 insulative
wall sheathing beneath the new
siding
INSULATED wood-frame wall:
For Zones 4 to 8: Add R5 insulative
sheathing before installing the
new siding
ADD INSULATION
TO ATTIC
ZONE
1
2
3
4
5 to 8
FLOOR
R13
R13 to R19
R19 to R25
R25 to R30
R25 to R30
Uninsulated Attic
R30 to R49
R30 to R60
R30 to R60
R38 to R60
R49 to R60
* These recommendations are cost-effective
levels of insulation based on the best available
information on local fuel and materials cost
and weather conditions. Consequently, the
levels may differ from current local building
codes. In addition, the apparent fragmentation
of the recommendations is an artifact of these
data and should not be considered absolute
minimum requirements.
All of Alaska in Zone 7 except for
the following Boroughs in Zone 8:
Bethel Northwest Arctic
Dellingham Southeast Fairbanks
Fairbanks N. Star Wade Hampton
Nome Yukon-Koyukuk
North Slope
Calculate How Much Greenfiber
®
Insulation You Need
1
DM-6.3-38 Rev D 3-21
For further installation instructions visit
https://www.greenfiber.com/install