Specification

FACT SHEET
30 lbs (13.6 kg)
Application Coverage Chart
READ THIS BEFORE YOU BUY
What you should know about R-values
FOR MORE INFORMATION CONTACT:
GreenFiber Corporate Office
2500 Distribution Street, Suite 200
Charlotte, NC 28203
(p) 800.228.0024 (f) 704.379.0685
(e) greenfiber.info@greenfiber.com
www.greenfiber.com
MANUFACTURING LOCATIONS:
Albany, NY
Belchertown, MA
Delphos, OH
Norfolk, NE
Chandler, AZ
Salt Lake City, UT
Tampa, FL
Waco, TX
Wilkes-Barre, PA
PM-6.3-328 Rev B 03/15
THIS IS GREENFIBER
®
ALL BORATE LOOSE FILL FORMULA INSULATION
R-Value at
75° F Mean
Temp.
Valor de
resistencia
termica
(valor R) a
75 F de
temperatura
media
Minimum Thickness
(inches)
Expesor minimo
(en pulgadas)
Net Coverage
(no adjustment for framing)
Cubertura neta (sin compensación
para el estructura)
Net Coverage (adjusted for 2” x 6”
framing on 16” centers)
Cobertura neta (con compensación para una estructura
de 2“ x 6” en centros de 16”)
Initial
Installed
Thickness
Espesor
inicial
instalado
Maximum
Sq. Ft. per Bag
Metros
cuadrados
máximos
por bolsa
Maximum
Sq. Ft. per Bag
Pies
cuadrados
máximos
por bolsa
Mimimum
Bags per
1,000 Sq. Ft.
Cantidad minima
de bolsas por 1,000
pies cuadrados
Mimimum
Bags per
1,000 Sq. Ft.
Cantidad minima
de bolsas por1,000
pies cuadrados
Minimum
Weight per
Sq. Ft.
Peso minimo
por pie cuadrado
Settled
Thickness
Espesor
asentado
INS765LD
11
13
19
22
26
30
32
38
40
44
48
49
50
60
3.36
3.99
5.86
6.77
7.99
9.19
9.79
11.57
12.16
13.33
14.49
14.78
15.07
17.96
3.02
3.59
5.27
6.10
7.19
8.27
8.81
10.41
10.94
11.99
13.04
13.30
13.57
16.16
100.8
83.5
54.3
45.9
37.8
32.0
29.6
24.1
22.7
20.2
18.1
17.7
17.2
13.7
9.9
12.0
18.4
21.8
26.4
31.2
33.7
41.4
44.1
49.6
55.2
56.6
58.1
73.1
0.298
0.359
0.552
0.653
0.793
0.937
1.01
1.24
1.32
1.49
1.66
1.70
1.74
2.19
111.3
92.2
59.6
49.7
40.5
33.9
31.3
25.3
23.7
21.0
18.8
18.3
17.8
14.1
9.0
10.8
16.8
20.1
24.7
29.5
32.0
39.6
42.2
47.6
53.2
54.6
56.1
71.0
THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 30 LBS USING A VOLUMATIC III, 3rd GEAR AND 8" GATE. THE CHART
IS BASED ON SETTLED THICKNESS AND IS FOR ESTIMATING PURPOSES ONLY. DO NOT EXCEED MAXIMUM SQUARE FEET COVERAGE PER BAG.
THE APPLICATOR MUST INSTALL BOTH THE MINIMUM NUMBER OF BAGS PER 1000 SQ. FT. AND THE MINIMUM INSTALLED THICKNESS TO
INSURE THE STATED R-VALUE HAS BEEN REACHED. FAILURE TO MEET BOTH THESE REQUIREMENTS MAY PREVENT THE APPLICATION OF
SPECIFIED R-VALUE. THIS PRODUCT IS INTENDED FOR DRY APPLICATION ONLY. JOB CONDITIONS, APPLICATION TECHNIQUES, EQUIPMENT,
AND SETTING CAN INFLUENCE ACTUAL COVERAGE. DO NOT ADD WATER TO THIS PRODUCT. MINIMUM NET WEIGHT IS 28.5 LBS.
Estructura
(inches)
(pulgadas)
Thermal Resistance
(R value)
13
21
2x4
2x6
3.5
5.5
1.02
1.60
29.39
18.70
32.4
20.6
31.3
19.9
Dry Dense Pack Sidewall Applications (3.5 pcf minimum installed density)
30 lbs. (13.6 kg) INS765LD
Resistencia térmica
(R)
Framing Installed Thickness
Espesor instalado
Maximum Coverage Per Bag
(Adjusted for Framing) ft
2
/Bag
Cobertura máxima por bolsa
(con compensación para la estructura)
ft
2
/Bag
Maximum Coverage Per Bag
(No Adjustment for Framing)
ft
2
/Bag
Minimum Wt.
Per Square Foot
lb/ft
2
Peso mínimo por
pie cuadrado
lb/ft
2
Cobertura máxima por bolsa
(sin compensación para la estructura)
ft
2
/Bag
(16oc) (24 oc)
This chart shows the R-value of this insulation. R means resistance to heat flow. The higher the
R-value,the greater the insulating power. Compare insulation R-values before you buy. There are
other factors to consider. The amount of the insulation you needdepends on the climate you live in.
Also, your fuel savings from insulation will depend upon the climate, the type and size of your
house, the amount of insulation already in your house, and your fuel use patters and family size. If
you buy too much insulation, it will cost you more than what you’ll save on fuel. To get the marked
R-value, it is essential that this insulation be installed properly.
THIS COVERAGE CHART IS FOR DRY
APPLICATIONS ONLY AND IS BASED
ON THE KRENDL KS200, WITH MATERIAL
APPLIED DRY. FOR MAXIMUM
COVERAGE PER BAG (ADJUSTED FOR
FRAMING), THE FRAMING FACTOR FOR
16" OC STUD SPACING IS 9.375%; FOR
24" OC STUD SPACING THE FRAMING
FACTOR IS 6.25%.

Summary of content (1 pages)