version:1.0 User Manual Wi-Fi Smart Scale GBF-1270-F2 Thank you very much for selecting the Transtek Wi-Fi Smart Scale GBF-1270-F2. ZHONGSHAN TRANSTEK ELECTRONICS CO., LTD No.23,Jin'an Road, Minzhong, Zhongshan, 528441, Guangdong, China TEL:86-760-88282982 www.transtek.cn Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product, and keep the manual well for further reference in case you have problems.
Table of Contents Table of Contents Safety Information Safety and Usage Information .................................................................................................. 2 Your Scale and Its Environment ............................................................................................... 3 Efficient Use of Your Scale ........................................................................................................ 3 Overview Device Components ...................................
Safety Information Safety Information Safety and Usage Information INDICATIONS FOR USE The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury.
Overview Overview Device Components LCD Display LCD Display Up Key Down Key Set Key Body Fat Analysis Result Male Body Water Analysis Result Male Athlete Battery Compartment Muscle Mass Analysis Result Female Sensor Bone Mass Analysis Result Female Athlete Your Goal Weight Kilogram Body Mass Index Pound Age Setting Mpde Inch Percentage Centimeter User ID (Range form U1 to U8) Data transmitting / pending to transmit to wireless wellness system Successful Wi-Fi Connection UNIT and
Initial Start-Up Initial Start-Up Set Up Your Profile General Instructions Transtek Wi-Fi Smart Scale GBF-1270-F2 applies BIA (Bio-impedance Analysis) technology. A small amount of weak current flows through the human body so as to detect the bio-impedance and estimate BMI, body fat, body water, muscle mass and bone mass. The electrical current is small and may not be felt. This BIA technology is cheap, safe, non-invasive, toxic-free and harmless.
Initial Start-Up Initial Start-Up 5.Setting Age After confirming Stature, the system will divert to Age setting. As pictured below, the digits “35” blinks. The operator may press the function key or to increase or decrease the numeral. You may press and hold the function key or for fast changing the numeral. Press “SET” key to confirm Age. When the LCD displays “STEP ON”, you may start. 6. Repeat procedure for a second user, or to change user details.
Initial Start-Up Initialising Your Scale 1. Press the platform centre and remove your foot. 2. “0.0” will be displayed. Start Measuring First Measurement Please process the user setting before your first measurement. (Refer to Set Up Your Profile for more details) STEP 1: Step on the platform barefooted when the LCD display “STEP ON”. 3. The scale will switch off and is now ready for use. This initialisation process must be repeated if the scale is moved. At all other times step straight on the scale.
Start Measuring Manage Your Health Daily Measurement With original SENSE ON patent technology, GBF-1270-F2 will switch on as you step on the platform barefooted. Stand still and keep full contact with the scale until the LCD stops blinking unit. After the weight is locked, the circle of LCD runs clockwise. If identify the stored weight is during this weight within+/-4.5 kg,it will identify the specific user ID.
Troubleshooting Troubleshooting Error Prompt Error Description Overload. The device will power off. Low Battery. The device will power off. Failure of pairing up your scale with your smartphone. There has data doesn’t upload. (The notebook icon will be displayed.) Solution Stop using this scale for measurement. Replace all four batteries in the same time. Please purchase the authorized batteries for replacement. Please check below items: -Wi-Fi is ON. -APP Collector is ON.
Troubleshooting Specifications Specifications Product Name When Data Transmitting ... Problem Root Cause Wi-Fi is OFF. Data transmission failed. The APP is OFF. Solution Turn ON the Wi-Fi via Setting. Dimension Scale: 321x321x24.5mm (Approximately) Net Weight Approximately 1.98kg ( Including the dry cells) Display Measurement Unit Press the icon to turn ON your APP. Measurement Range Division Accuracy Out of range of Wi-Fi transmission. Place your smartphone closer to the scale.
Maintenance Maintenance When carrying out usual maintenance, please ensure practice of the following Do’s and Don’ts: DO use a dry soft cloth to wipe the dust. DO use a wet soft cloth, dipped into water and wrung out, to wipe the dirt. Then use a dry soft cloth to dry up the device. DON’T wash the device with water or immerse it in water. DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of discolor or malfunction. DON’T disassemble this device.
Appendix Appendix Health Tips - About Body Fat Health Tips - About Body Water Body water is the single most important component of body weight. It represents over half of your total weight and almost two thirds of your lean body mass (predominantly muscle). Water performs a number of important roles in the body: All the cells in the body, whether in the skin, glands, muscles, brain or anywhere else, can only function properly if they have enough water.
Appendix Appendix Health Tips - About Muscle Mass According to the American College of Sports Medicine (ACSM), lean muscle mass may decrease by nearly 50 percent between the age of 20 and 90. If you do nothing with it you’re losing muscle and increasing fat. It is also important to know your muscle mass % during weight reduction. At rest, the body burns approximately 110 additional calories for each kilo of muscle gained.
Appendix Appendix EMC Guidance Table 2 Guidance and manufacturer’s declaration - electromagnetic Immunity Guidance and manufacturer’s declaration -electromagnetic emissions and Immunity Immunity Test IEC 60601-1-2 Compliance level Test level Table 1 Guidance and manufacturer’s declaration - electromagnetic emissions Emissions test RF emissions Compliance Group 1 ±8 kV contact ±8 kV contact IEC 61000-4-2 ±2 kV, ±4 kV, ±8 kV, ±15 kV air ±2 kV, ±4 kV, ±8 kV, ±15 kV air Electrical fast transient
Appendix Table 3 Radiated RF IEC61000-4-3 (Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) Guidance and manufacturer’s declaration - electromagnetic Immunity Test Frequency (MHz) Band (MHz) Service Modulation Modulation (W) Distance (m) 385 380 – 390 TETRA 400 Pulse modulation 18 Hz 1,8 0.3 IMMUNITY TEST LEVEL (V/m) 27 450 430 – 470 GMRS 460, FRS 460 FM ± 5 kHz deviation 1 kHz sine 2 0.