Pr-Installation Procedure 1. Relieve the pressure. “To reduce the risk of serious injury whenever you are instructed to reflexive pressure, always follow the Pressure Relief Procedure on page 6. 2. Close the shut-off naive (J). See Fig. 2, 8. Ground the hose and reel or console. See Ground. ing on page 8. Installation Procedure /\ CAUTION + It this Is a new installation or if the fluid in the fines is contaminated, flush the lines before you install the metered valve.
hose ding shine onto % J hose before connecting Fic. 3 model shown has 45° bend rigid extension 2c nozzle is not serviceable. Meter Installation Grounding Fire, Explosion, and Electric Shock Hazard / When operating the Electronic Meter any ik grounded objects in the spray area (people, containers, tools, etc.) ean become We electrically charged. Improper grounding can result in static sparking, which can E-] cause a fire, explosion, or electric shock. Follow the grounding instructions below.
Setup Keypad Buttons The buttons on the keypad are used to select meter functions and enter PIN codes. See Fig. &: * left arrow up (A) * right arrow down (B) * center arrow up (C) «center arrow down (0) NOTE: Asleep / Awake Asleep is a battery-saving mode in which the display goes blank after 2 minutes of inactivity during normal operation. The display comes awake from sleep mode when any button is pressed, or when the trigger is pulled.
Battery Charge Indicator On the right side of the display is a series of four bars under the word BAT. See Fia. 9. The presence of all four bars indicates a fully charged battery. The bars decline in number as the battery discharges when the meter is used. When one bar is shown the battery needs to be recharged. Fig. 8 Security When the meters were originally programmed one of the following security choices was entered: * Tracking mode + PiN Code » Parts Room Security mode.
Operation Pr-programmed Dispense Options The meter dispense options were programmed using the Matrix software at the time the meter(s) were first set up. The meter is programmed for either: Manual Dispense Mode Preset Dispense Mode NOTE: To change the meter from one mode to another it is necessary 10 reprogram the meter. See Programming the Meter on page 5. Dispensing Fluid in Manual Mode This mode provides meter operators with the greatest level of simplicity.
Operation Note: if “End” is not pressed the meter will time out and . ™ Iog the dispense lo the PC. Quick-Lock ~ Nozzle 1 To close the nozzle to prevent dripping, rotate left {counter clockwise} until tight {approximately 1/4 turn). See Fig. 14. 2. To open the nozzle for dispensing, rotate right {clockwise) until fully open (approximately 1/4 turn). \ Open 1/4 turn Siw Close 1/4 Turn Removing and Replacing the Battery 1.