Installation Guide

Majestic LED Flush Mount (Page 1)
Montage encastré du luminaire à DEL de style Majestic (Page 2)
Luces LED de montaje al ras Majestic (Página 4)
Model/Model/Modelo #:
ENGLISH
WARNINGS AND CAUTIONS
SHUT OFF POWER AT THE CIRCUIT BREAKER OR FUSE PANEL BEFORE
REMOVING THE OLD FIXTURE AND/OR INSTALLING A NEW ONE.
Read entire installation procedure before you begin and save instructions and the receipt
for future reference.
THIS FIXTURE IS DIMMABLE BY SPECIFIC FORWARD PHASE ELECTRONIC (TRIAC)
DIMMERS. Dimmers tested to be compatible with this fixture are the Lutron Skylark
®
SCL-153P*,
Diva
®
DVCL-153P*, Maestro
®
MACL-153M*, Toggler
®
TGCL-153P*, Lumea
®
LECL-153P*,
Caseta
®
PD-6WCL*, Eaton Halo
®
SAL06P*. (This list of dimmers does not imply any guarantee or
warranty of compatibility with a particular application. Dimmers not listed do not imply
non-compatibility.)
1
Remove the three post caps, diffuser, and the first decorative ring, and set aside until step 6.
Use the existing electrical box screws or the included box screws in the hardware kit. Drive the screws (AA) into the electrical junction box (J-Box) until there is about 3/8 in (1
cm) between the ceiling and the underside of the screw head.
The fixture must be properly grounded. If the J-box has a ground wire, connect the fixture ground wire to the ground wire from of the J-Box using wire nut (BB). Ground wires are
normally green or bare copper. Connect the black supply lead with the black fixture wire and the white supply lead with the white fixture wire using wire nuts (BB). Push
connections and excess wire up into the J-box.
2
3
4
5
6
2
* Actual hardware may differ from illustration.*Les éléments de fixation réels peuvent être différents de
ceux de l’illustration.*Los herrajes reales pueden diferir de los que se muestran en la ilustración
6
4
1
5
Hardware kit*/
Trousse de quincaillerie*/
Kit de aditamentos*
AAx2
AAx2 BBx3
Required/
Nécessaire/
Obligatorio
READ ENTIRE INSTALLATION PROCEDURE BEFORE YOU BEGIN!
TURN POWER OFF AT BREAKER BOX/FUSE BOX. TURN WALL SWITCH TO JUNCTION BOX OFF
If unsure if the electrical box is properly grounded, or the box is plastic
and has no ground wire, or are unfamiliar with the methods of properly
grounding fixture, consult a qualified electrician.
IMPORTANT SAFETY INFORMATION
1. Do not look directly at LEDs for extended period of time.
2. Suitable for INDOOR damp locations.
3. TURN POWER OFF BEFORE SERVICING.
4. Do not leave bare wires exposed.
5. For electrical requirements, see fixture. Minimum 90 °C supply conductors.
5/8in./
1,6cm
Locate the keyhole slots on the pan. There are 2 sets of keyhole slots on the fixture pan, the inner two will accommodate a standard J-Box. Position the keyhole slots over both
box screws protruding from the J-Box. Insert both screw heads through the larger round end of both keyhole slots. Twist the pan clockwise until both screw heads are captured
in the narrow chanels of the keyhole slots. Carefully tighten the screws down securely, without distorting or damaging the fixture pan.
Lift the diffuser into place and hold.
While holding the diffuser and place the bottom decorative ring into place. Align the three holes in the diffuser ring with the three posts on the fixture pan. Once the ring is in
place, attach the post caps and secure the diffuser ring to the fixture pan. Restore power to the electrical box to make sure the fixture is working properly.
3
BBx3
Fixture Pan
Panneau de fixation du luminaire
Bandeja del accesorio para iluminación
Fixture Post
Montant de fixation du luminaire
Poste del accesorio para iluminación
Diffuser Ring
Anneau du diffuseur
Aro del difusor
Diffuser
Diffuseur
Difusor
Post cap
Capuchon du montant
Tapa de poste
FL1242-BK2-11LF1-G
FL1242-WHG-11LF1-G
FL1242-GY2-11LF1-G
FL1242-BK2-11LF1-G
FL1242-WHG-11LF1-G
FL1242-GY2-11LF1-G
FL1242-BK2-17LF2-G
FL1242-WHG-17LF2-G
FL1242-GY2-17LF2-G
FL1242-BK2-17LF2-G
FL1242-WHG-17LF2-G
FL1242-GY2-17LF2-G
FL1242-BK2-14LF1-G
FL1242-WHG-14LF1-G
FL1242-GY2-14LF1-G
FL1242-BK2-14LF1-G
FL1242-WHG-14LF1-G
FL1242-GY2-14LF1-G
SAVE AND ATTACH RECEIPT HERE
INFORMACIÓN DE SEGURIDAD IMPORTANTE
1. No mire directamente las luces LED durante un período largo.
2. Accesorio para iluminación adecuado para lugares húmedos INTERIORES.
3. DESCONECTE LA ALIMENTACIÓN ELÉCTRICA ANTES DE HACER
SERVICIO DE AJUSTES Y REPARACIONES.
4. No deje conductores desnudos expuestos.
5. Para conocer los requisitos eléctricos, fíjese en la lámpara. Conductores de
electricidad para 90°C como mínimo.

Summary of content (4 pages)