User's Manual

Walgreens Installation Guide
G-1-2002-2B
Walgreens Installation Guide 2B.doc
Use or disclosure of this document is covered under the Non-Disclosure Agreement executed between the reader and Goliath Solutions,
LLC. This document and the information contained herein are privileged and should only be viewed by expressly authorized parties.
5/27/2008 Page: 2-56
Installation of Rx/ARA Antennae in the Stock Room:
1) Two Rx/ARA antennas will be installed in a standard Stock Room. Verify that the
cables will reach the designated antenna location. In an exception site more that two
Rx/ARA antennas could be installed in a stock room.
2) Mount the Rx/ARA to the roof girder at the designated location using cable ties.
The
bottom of the Rx/ARA must always be facing the floor.
The Rx/ARA must be mounted to the girder with the top of the antenna casing
touching the girder. The top is designated by a label showing the Rx/ARA model
number. The flat area on the top of the antennae, not the raised edge should be
touching the girder.
To mount an Rx/ARA with cable ties, one must insert a tie through the hole in
one corner of the top of its casing. Insert a second tie into the hole at the
opposite corner of the casing.
Attach the Rx/ARA to the roof girder so that the antenna is configured on the
girder as shown in the examples below.
Be careful to mount the Rx/ARA so that it is level (parallel to the floor) and NOT
angled in any way.
The Rx/ARA and cable should not touch any power conduit or any other pipes.
The Rx/ARA must have a clear line of site to the floor. There can not be any pipes
or conduit between the Rx/ARA and the floor.
Do not mount the Rx/ARA over liquids. Beverages are normally kept next to the
shelving unit near the receiving door. This is close to the designated position for
RX16.
There can not be any obstructions between the Rx/ARA and floor.
3) Power conduit or other pipes on or below the roof girder at the designated location
for an Rx/ARA may prevent the mounting of the Rx/ARA on the roof girder at that
location. In this case look for an alternate location on the girders close (within a few
feet) to the designated location or use the suspended mount method to hang the
Rx/ARA. If you suspend the Rx/ARA make sure the Rx/ARA has no obstructions
between the bottom of the antenna and the floor.
4) Create the service loop per the previously stated standard and then connect the
coaxial cable to the antenna.
The excess cable at the antenna point of termination must be looped (coil should
be no less than ten (10) inches in diameter) and secured to itself using cable ties.
Be very careful not to kink or bend the cables.
The loop must then be placed on top of the roof girder, directly above the antenna
and secured to the girder via a cable tie.
Be careful not to tighten the cable tie to the point where the cable is pinched or
kinked.