Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 501-000669/MN User’s handbook Digital radio link EK-MFR/1 EK-CDP/1 board Eurotek s.r.l. Pag.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag. 2 of 19 501-000669/MN REGULATORY COMPLIANCE (USA) This equipment requires licensing for operation under FCC Title 47 part 101 This equipment generates, uses and radiates electromagnetic fields that could cause interference to radio communications, is more important that it is installed and used in accordance with the instruction that are explained in this manual.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag. 3 of 19 501-000669/MN Warning! The socket utilized for the unit supply must have the appropriate ground conductor. The connection of the unit , to a socket without the ground conductor, will make the whole equipment dangerous for people safety. About the repairing of the units please refer to specialized personnel only . Inside the devices there are voltages which could be dangerous to people.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag. 5 of 19 501-000669/MN INDEX 1. 2. 3. 4. GENERAL DESCRIPTION ..................................................................................................... 6 BOARD PANEL ......................................................................................................................... 7 2.1 BOARD PANEL REPRESENTATION ...........................................................................................7 2.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag. 6 of 19 501-000669/MN 1. GENERAL DESCRIPTION The EK-CDP/1 board allows to connect the EK-MFR/1 unit to the SHF parts inserted into the Eurotek Out Door Units (ODU) and allows the use of every frequency band, at present, available. Thanks to the use of two N type connectors every single board can control simultaneously two external sections (ODU) in completely independent way one from the other.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag. 7 of 19 501-000669/MN 2. BOARD PANEL 2.1 Board panel representation 2.2 Board panel description A) B) C) D) E) N type connector. IF frequency transmission input connector. IF frequency received input connector. N type connector. Yellow led: indicates, if it is on, that the received IF signal, present on the BNC connector (C), is selected.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Pag. 8 of 19 Rev. D of 28/06/2007 501-000669/MN 3. 3.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 3.2 Pag. 9 of 19 501-000669/MN Menu description and keyboard guide The user can enter every menu and sub-menu using the “explore menu” key to set the value of any variables, using the “modify variable” key and to confirm the modify, pressing the “enter” key (EKMFR/1 user ‘s handbook, front panel description paragraph). >Status >>Power Rx The user can read the power rx level of the board with the relative unit of measurement.
Series EK-MFR/1 EK-CDP/1 board Rev. D of 28/06/2007 Arch.2577 Pag. 10 of 19 501-000669/MN >ODU RX Set >>Ch Rx It is possible, if synthesized ODU are used, to change the receiver channel. The number of the channels are included between 1 and 256 with a step of 1. >>Enable Rx This menu allows to enable the receiving ODU (out door unit). If the variable “yes” is settled, the ODU is enabled, while if the variable “no” is settled, the ODU is disabled. >>IF BW It is possible to set the receiver IF bandwidth.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag. 11 of 19 501-000669/MN >Revision This menu allows to read the software revision implemented on the programmable devices of the board. The software configuration of the board is realized to obtain the release of the following programmable devices (DSP, FPGA, CPLD, RamDisk). The release version of the FPGA is not available because the device is not present on the board.
Series EK-MFR/1 EK-CDP/1 board Rev. D of 28/06/2007 Arch.2577 Pag. 12 of 19 501-000669/MN The example below explains how to set the frequency value of the gain control of the board (Rx menu). When the EK-MFR/1 is configured (EK-MFR/1 user ‘s handbook, display and keyboard description paragraph), it is possible, using the “explore menu” keys (EK-MFR/1 user ‘s handbook, front panel description paragraph), to see the boards that are inserted in the system.
Series EK-MFR/1 EK-CDP/1 board Rev. D of 28/06/2007 Arch.2577 Pag. 13 of 19 501-000669/MN When the ODU RX Set menu is selected (above view), pressing the “enter” key it is possible to enter in the sub-menu of the ODU RX Set menu and, using the “explore menu” keys, to run until the Rx menu as follow: Entering in the Rx menu, it is possible to see the actual value of the board gain control (in the above view: agc).
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 Pag. 14 of 19 501-000669/MN 4. WEB PAGE The EK-CDP/1 board is supplied of a web page that allows to obtain a complete view of the status of the board variables. When the EK-MFR/1 system is connected to a terminal unit (PC) and the web pages of the system are loaded (EK-MFR/1 user ‘s handbook, web interface chapter), the user can see the following EK-MFR/1 main web page: Eurotek s.r.l.
Series EK-MFR/1 EK-CDP/1 board Rev. D of 28/06/2007 Arch.2577 Pag. 15 of 19 501-000669/MN The EK-CDP/1 board is loaded in the slot number three; to visualize the web page of the board it is necessary to move, using a mouse, the cursor on the slot associated to the board (slot 3) and then to click the left mouse button on its. So we obtain the following image: The web page of the EK-CDP/1 board is showed above. In the top section, are reported the version of the software tool (v 1.
Series EK-MFR/1 EK-CDP/1 board Rev. D of 28/06/2007 Arch.2577 Pag. 16 of 19 501-000669/MN The next example shows how to set a variable value of the board. The procedure to set every variable value is similar to this. We suppose to enable the transmitting ODU by the Enable Tx variable. This parameter is located in the ODU TX Set menu of the board so when the menu is selected, on the page we can see the following situation: Eurotek s.r.l.
Series EK-MFR/1 EK-CDP/1 board Rev. D of 28/06/2007 Arch.2577 Pag. 17 of 19 501-000669/MN Moving the cursor, using a mouse, on the Enable Tx box and pushing the left mouse button on the black indicator, it is possible to see the available value to insert for this parameter. Eurotek s.r.l.
Series EK-MFR/1 EK-CDP/1 board Rev. D of 28/06/2007 Arch.2577 Pag. 18 of 19 501-000669/MN To enable the transmitting ODU, the “Yes” value must be settled as the following figure shows: We have settled, for example, the refresh time parameter on the 30 seconds indicator, so every thirty seconds the system variables are refreshed. When the refresh countdown is complete the refresh label is flashing.
Series EK-MFR/1 EK-CDP/1 board Arch.2577 Rev. D of 28/06/2007 501-000669/MN Eurotek S.r.l. c/o Parco Scientifico Tecnologico e delle Telecomunicazioni in Valle Scrivia Strada Comunale Savonesa, 9 15050 RIVALTA SCRIVIA (AL) tel. +39 (0)131 860205 r.a. fax +39 (0)131 860993 http://www.eurotektel.com e-mail: info@eurotektel.com Eurotek s.r.l. Pag.