*** USER’S MANUAL *** FCC ID: WXAMINI400B
-1- TM951241
......................................................................................... 3 .......................................... 6 Connections ......................................................................................... 9 Information Technical And Operational Description Card Data Format Specifications ............................................................................ 10 .....................................................................................
Mini400B Series Magnetic Swipe Reader MACHINE TYPE FUNCTION MC 123 Li-Polymer Muti-Charge BlueTooth 2048 LED STATUS REC QUEUE USB Ver 1.1 Mini400B OFF AUTO OFF F - MEM 512 KB Rechargeable GNET RTC FFM VER 1.2 Track 1 & 2 & 3 Bluetooth adaptor Installation Refer to page10 Read the instructions on your device before installing batteries 1. Insert batteries into your device properly, with the (+) and (-) terminals aligned correctly. 2. Always fully charge your batteries before use. 3.
Information Lithium Ion Polymer Battery Handling Guideline Danger ! It may cause the battery swelling, leaking, explosion or ignition, if you do not reading following: 1. Do not store battery in a manner that allows terminals to short. 2. The cell batteries are requested to be stored within a proper temperature range specified in this specifications. 3. Use only approved charger (Mini123EX).Improperly charging a cell or battery may cause the cell or battery to flame or damage. 4.
Information Standard Package CD-ROM ( DISK5269 ) Main unit ( Mini400B ) Chain Sling ( TM09F1001 ) Option Li-Polymer Rechargeable Battery 3.
Front Panel Display and Operations Battery Box Power & Control Button Connector Card Reader Power ,Memory ,Read Status Bluetooth & Battery Status LED indicator LED indicator Card Reader Swipe the card through the entire length of the slot to read. Power,Memory,Read Status LED Indicator When encountering erroneous input, defective card, misread,bad memory or incorrectly encoded data and so on, the device will turn on the ERROR indicator .
Technical And Operational Description Display Information Power,Memory,Read Status LED Indicator Status Green LED Red LED Buzzer Read Card *1 Power On Take turns blink 2 times Beep. Beep. X Auto Power Off Take turns blink 2 times Beep. Beep. X Ready On Off X O Read OK Blink 1 times Off Beep. X Read Error Off Blink 1 times Beep. Beep. Beep. X Inactive Battery Off Blink 3 times Beep. Beep. Beep.
Technical And Operational Description Operational Description 1. Powered by Battery For normal use, the unit is powered by battery. Push the Power Switch Button for about 1.5 seconds to turn on the unit. Also push the Power Switch Button for about 1.5 seconds to turn off the unit. After the unit is turned on, the power would be turned off automatically if there is no swiping a card on the unit in 30 seconds.
Connections WAS-T0233 1 1 USB 4P FEMALE PIN 1 3 2 4 FUNCTION VCC DD+ GND MINI USB 4P 1 2 3 4 FUNCTION VCC RXD TXD GND Connect to PC USB PORT Personal Computer Mini400B Note: 1. When Mini400B is connected/disconnected to USB port, it would be turned On/Off automatically. 2. Normally the charging time is about 1.5 ~ 2.5 hours (Default setting is low battery charge mode, it is detected when the battery is low, it would be charge until Full automatically).
CARD DATA STRING TRACK 1 TRACK 2 TRACK 3 DATE & TIME SS TRACK1 DATA ES SS TRACK2 DATA ES SS TRACK3 DATA ES % TRACK1 DATA ? ; TRACK2 DATA ? + TRACK3 DATA ? SP DATE SP DATE TIME SP TIME WEEK WEEK TRACK 1 % CARD ID ? Track 1 IATA Bits Per Inch 1. SS is the start sentinel ( % ). 2. ES is the end sentinel ( ? ). 3. Card Id up to 76 alphanumeric data characters. 210 Bits Per Character 7 Alphanumeric Characters 79 TRACK 2 ; CARD ID ? Track 2 ABA Bits Per Inch 1.
MC 123 Magnetic Stripe Card : TRACK 1 / IATA / 210 bpi / 79 Alphanumeric Characters TRACK 2 / ABA / 75 bpi / 40 Numeric Characters TRACK 3 / Thrift / 210 bpi / 107 Numeric Characters BlueTooth Bluetooth Interface : SPP Profile ,Class 2 ,Compatible Bluetooth V2.0+EDR,V1.2,V1.1 USB Ver 1.1 USB Interface Full compliance with the USB Specification V 1.1 The device uses a Virtual Serial Port Driver, making it appear to have the software like a standard RS232 Serial Port. GNET VER 1.
GNET FEATURES Support TTY (TELE TYPE) OPERATION Use TTY to send commands and messages. Simple handshaking One enquiry one answer back. Multi-link capability Expandability GNET provides 4 major functions: 1. POLLING 2. LOGIN / LOGOUT 3. DATABASE 4. INFORMATION Also can be expandable. Simple format Use ASCII value for each field and use Separator "," between two Fields.
Communication Protocol Command Index Table Topic Command Contents Description L O P B C F S T N G E 4 Characters for Login(0000) - Login Logout Set Password Get Register Set register Get Product Version Set Date,Time and Week Get Date and Time Get Number of Record Read Record by Number Erase All Record Contents Reply Information See Error Index Table Description ACK+Information NAK+Information SETTING DATABASE New four digit password Date,Time,Week Number Reply Index Table Topic ACK NAK Repl
Communication Protocol 1. GET NUMBER OF RECORD : STX N STX A NUMBER CR NUMBER CHKSUM CR Record Count . 4 Bytes Width ( 0000h ~ 0080h ) EXAMPLE 02 N 0d 02 A 000C 14 0d The Total of Record Count : 12 2. READ RECORD BY NUMBER : STX G NUMBER STX A NUMBER , NUMBER DATA CR DATA CHKSUM CR Record Count .
Communication Protocol 4. SET DATE AND TIME : STX S STX A YYYY MM DD hh mm ss W YYYYMMDDhhmmssw CR CR Week SUN MON TUE WED THU FRI SAT Year (1980 - 20xx ) Month (01 - 12 ) Date ( 01 - 31 ) Hour ( 00 - 23 ) Mintue ( 00 - 59 ) Second ( 00 - 59 ) Week ( 1 - 7 ) 1 2 3 4 5 6 7 EXAMPLE 02 S 200005051230006 02 A 0d 0d Set Date = 2000 / 5 / 5 Set Time = 12 : 30 : 00 , Friday 5.
Communication Protocol EXAMPLE 02 F 0d 02 A V1.0R00 0d Firmware Version = 1.0 Modify times = 0 7. SET REGISTER : STX C STX A REGISTER PARAM CHKSUM REGISTER , PARAM CHKSUM CR CR Register Address . 2 Bytes Width ( 00h ~ FFh ) Set Parameters of Register C + REGISTER + , + PARAM 7-1.
Communication Protocol EXAMPLE 02 C 10 02 A 0d , 0A 41 0d Modem : 2400 Non- modem : 9600 Write to Parameter Table Address : 10 h Auto Power Off Time (Low Byte) : 5 Seconds 7-3. SET AUTO POWER OFF TIME (HIGH BYTE) : STX C STX A 11 , SECH CHKSUM CR CR SECH (00-FF)/2 *256 Seconds "00-FF" EXAMPLE 02 C 11 02 A 0d , 02 33 0d Modem : 2400 Non- modem : 9600 Write to Parameter Table Address : 11 h Auto Power Off Time (High Byte) : 2/2*256 Seconds 7-4.
Communication Protocol 7-5. SET TRACK ACTIVE MODE : STX C STX A TRACK , MODE CHKSUM CR CR TRACK "30" "31" "32" MODE TRACK 1 TRACK2 TRACK3 "FF" "00" "01" ENABLE DISABLE REQUIRED EXAMPLE 02 C 30 02 A 0d , FF 5E 0d , MODE 71 0d Write to Parameter Table Address : 30 h TRACK ACTIVE MODE : TRACK 1 ENABLE . 7-6.
Communication Protocol 8. GET REGISTER : STX B REGSTER STX A PARAM REGSTER PARAM CR CHKSUM CR Register Address . 2 Bytes Width ( 00h ~ FFh ) Set Parameters of Register 8-1. GET POWER MODE : STX B 12 CR STX A MODE CHKSUM CR Same 7-1. SET POWER MODE EXAMPLE 02 B 12 0d 02 A 00 A1 0d Write to Parameter Table Address : 12 h Get Power Mode : Real Control 8-2. GET AUTO POWER OFF TIME (LOW BYTE) : STX B 10 CR STX A SECL CHKSUM CR Same 7-2.
Communication Protocol 8-3. GET AUTO POWER OFF TIME (HIGH BYTE) : STX B 11 CR STX A SECH CHKSUM CR Same 7-3. SET AUTO POWER OFF (HIGH BYTE) EXAMPLE 02 B 11 0d 02 A 02 A3 0d Get Parameter From Parameter Table Address : 11 h Auto Power Off Time Period (High Byte) : 2*256/2 Seconds 8-4. GET SOUND MODE : STX B 19 CR STX A SECH CHKSUM CR EXAMPLE 02 B 19 0d 02 A FF CD 0d Get Parameter From Parameter Table Address : 19 h SOUND MODE : ENABLE 8-5.
Communication Protocol 9. LOGIN : STX L PASSWORD STX A PASSWORD CR CR 4 Characters for Login. 0000=Initial value EXAMPLE 02 L 02 A 0000 0d 0d Login password : 0000 10. LOGOUT : STX O CR STX A CR EXAMPLE 02 O 0d 02 A 0d Logout 11.
Communication Protocol 12. GET/SET BLUETOOTH NAME(only workable with cable WAS-T0233) : STX K STX A 1 G/S NAME CR CR NAME default setting=MINI400 EXAMPLE G=GET 02 K 1 02 A 0d G MINI400B 0d S=SET 12-1. GET/SET BLUETOOTH PIN CODE(only workable with cable WAS-T0233) : STX K STX A 2 G/S PIN CODE CR CR NAME default setting=MINI400 EXAMPLE G=GET 02 K 2 02 A 0d S=SET G 1234 0d Set new PIN CODE : 1234 12.