Installation Guide

INSTALLATION INSTRUCTIONS FOR P472-X-L
For Wall Mount Fixture
WAR NING! SH UT POWER O F F AT F US E OR CI RC UIT BREAKER .
AV E R T I S S E M E N T ! C O U P E R L E C O U R A N T A U N I V E A U D E S F U S I B L E S O U D O D I S J O N C T E U R .
PREPARATION
1. Shut off power at the fuse box or circuit breaker box. If
necessary, remove the old fixture and mounting
hardware.
2. Carefully unpack your new fixture and lay out all the
parts on a clear area. Take care not to lose any small
parts necessary for installation.
MOUNTING THE FIXTURE (FIG. 1)
3. Secure mounting back plate (A) to the outlet box
using junction box screws (B) (Size: 8-32*1/2”L). The
side of the mounting back plate marked “GND” must
face out.
CONNECTING THE WIRES (FIG. 2)
4. At this point, connect the electrical wires as shown in
Fig. 2, making sure that all wire connectors are
secured. If your outlet has a ground wire (green or
bare copper), connect the fixtures ground wire to it.
Otherwise, connect the fixture ground wire directly to
the mounting back plate (A) using the green screw
provided. After wires are connected, tuck them
carefully inside the junction box.
5. Align fixture back plate (C) onto mounting back plate
(A) and secure with screws (D).
FINISHING THE INSTALLATION (FIG.1)
6. Align diffuser (F) followed by gaskets (O), onto
bracket (I) and secure with screws (G). The clear side
diffuser (F) should face down toward bracket (I).
7. Align cloth shade (H) (PS472) onto back plate (C) and
secure with screws (E)
CAUTION/ATTENTION: When handling the fixture, do
not apply pressure to the LEDs. Hold the fixture by the
base or front bracket (I) only.
IMPORTANT: Fixture should be installed by a qualified
electrician to ensure proper wiring and installation.
Replacing LED module (Fig. 3)
The LED module can be replaced by a qualified
electrician without cutting of wire and without damage to
any decorative element to which the fixture is attached.
See installation steps for more details (Fig 3.)
a. Shut off the power.
b. Remove screws (E) and cloth shade (H) from back
plate (C).
c. Remove screws (D) and carefully separate the fixture
from mounting back plate (A).
d. Remove the wire nuts (L) located inside the fixture
back plate to disconnect the LED module.
e. Remove screws (J) from heat sink(N).
f. Remove screws (K) on heat sink (N). Carefully
remove the LED module (M) from the heat sink (N),
g. Reverse steps b-f for installing the new LED module.
h. Note: The LED module should be provided by a
specified supplier.
i. For better heat dissipation the LED module (M)
should be applied with thermal grease when
re-lamping.
Fig.2
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
HOUSE
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
Fig.3
FIG.1
Set A# A-021-265106
Mounting Back Plate
Green Screw
Mounting Screws(2)
IMPORTANT: Fixture should be installed by a qualified
electrician to ensure proper wiring and installation.
Dimmable with ELV and/or LED compatible wall
dimmer switches.
LA-2979E