Operator's Manual

38832503793
Wireless Keypad Instructions
It is recommended to complete programming before mounting keypad
Keypad
Up/DownKey
(enter)
ProgramKey
LED
LEDO
LEDOn
LEDFlashing
KeypadO
KeypadOn KeypadFlashing
Keypad LED’s
Successful Entries Failed Entries
SAVE THESE
INSTRUCTIONS
FOR FUTURE
USE
WARNING
!
MOVING DOOR CAN CAUSE SERIOUS
INJURY OR DEATH.
•DO NOT install transmitter (keypad) unless the door operators
safety device works as required by the door operator’s manual.
•Wall Console must be mounted in sight of door, at least 5 feet
above oor and clear of moving door parts.
•Keep people clear of opening while door is moving.
•DO NOT allow children to play with the transmitter or door
operator.
If safety reverse does not work properly:
•Close door then disconnect opener using the manual release
handle.
•DO NOT use transmitter or door operator.
•Refer to Door and Door Opener Owners Manuals before
attempting any repairs.
AVERTISSEMENT
!
DÉMÉNAGEMENT PORTE PEUT CAUSER DES
BLESSURES GRAVES OU LA MORT.
•NE PAS installer le transmetteur (clavier) à moins que le dispositif
de sécurité de l’opérateur de porte ne fonctionne comme l’exige le
manuel d’utilisation de la porte.
•Console murale doit être monté en vue de la porte d’au moins 5
pieds au-dessus-de-chaussée et claire des pièces mobiles de la
porte.
•Garder les personnes clair de l’ouverture lorsque la porte est en
mouvement.
•Ne pas laisser les enfants jouer le premier match à distance ou la
porte.
Si la sécurité inverse ne fonctionne pas correctement:
•Fermer la porte, puis débranchez moteur à l’aide de la poignée de
déverrouillage manuel.
•Ne pas utiliser d’ouverture à distance ou la porte.
•Reportez-vous à la porte et ouvre-porte de propriétaires manuels
avant de tenter toute réparation.
Keypad LED will ash each time
a key is pressed and entry is
accepted.
Keypad LED and PROGRAM key
will ash slowly and number pad
back light will remain on for 15
seconds indicating a successful
program or valid PIN has been
entered.
Keypad LED, PROGRAM key and
number pad back light will ash
rapidly indicating a problem with
programming or an invalid PIN entry.
• Wait 15 seconds until back lighting
shuts o and enter a valid PIN or
reset keypad to reprogram.
FCC Part 15.21 Statement:
Changes or modications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.
FCC / IC Statement:
This device complies with FCC Part 15 and Industry Canada licence-
exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. Lexploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas
produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Single Door Operation:
1. Ensure number pad back lighting is o.
2. Enter PIN.
3. Press the UP/DOWN key.
4. Opener will operate.
Multi-Door Operation:
1. Ensure number pad back lighting is o.
2. Enter PIN.
3. Press the UP/DOWN key.
4. Press number key corresponding with desired door
(1, 2, or 3).
5. Desired opener will operate.
Changing an Existing PIN:
1. Enter current PIN
2. Press PROGRAM key once.
3. Enter new PIN (3-8 digits)
4. Press PROGRAM key once.
• Your PIN has been changed and your previous PIN will no
longer operate keypad or opener.
ADDITIONAL (OPTIONAL) PROGRAMMING:
Setting a Temporary PIN:
A temporary PIN allows temporary access to the garage
by normally unauthorized personnel such as repairmen or
neighbor.
1. Enter current PIN.
2. Press PROGRAM key 3 times.
3. Enter a temporary PIN (3 to 8 digits)
4. Press PROGRAM key once.
• The Temporary PIN will operate garage door opener until
the original PIN is used. Use of the original PIN will delete
temporary PIN.
For questions, comments or troubleshooting, contact The
Genie Company at:
1 Door Drive, Mount Hope Ohio, 44660
or call 1-800-354-3643 or visit our website at:
www.geniecompany.com
Keypad MUST be mounted within sight of the garage
door(s) at least 5 feet above oor and clear of any moving
door parts.
• Programming will not be lost during battery removal.
1. Remove battery cover and batteries.
2. Drill a 3/32” pilot hole for the top mounting screw.
3. Install included screw into pilot hole, leaving 1/8” gap
between the screw head and wall.
4. Hook the slotted mount on back of keypad over the
screw.
Wall
1/8"
Screw
head gap
5. Mark and drill a 3/32” pilot hole for the bottom screw
and secure keypad to the wall. (Do not over-tighten).
6. Reinstall batteries.
If the keypad back lighting fails to operate batteries may
require replacement.
• Programming will not be lost during battery change.
1. Remove battery cover and batteries.
2. Replace batteries with same type alkaline (AAA) and check
for proper direction of (+) and (-) terminals.
Rechargeable batteries are NOT recommended.
01/2018
STEP 4) OPERATING THE KEYPAD WITH THE OPENER(S)
STEP 5) MOUNTING THE KEYPAD
* RESETTING THE KEYPAD (FACTORY DEFAULT):
If the keypad has already been programmed or at any
time the programming should be erased and started from
the factory default, follow these steps.
1. Ensure that number pad back lighting is o.
2. Press and hold the PROGRAM and UP/DOWN Keys
together for approximately 5 seconds.
3. The LED will ash twice and all lights will go out
indicating the keypad has been reset.
4. Start at STEP 1 to sync the keypad to an opener.
For use with Genie Intellicode® garage door openers
Keypad Overview
Activate keypad by opening battery
compartment and pull protective
tab. Reinstall compartment door to
begin programming.
TAB
NOTE: Keypad will remain active for 15 seconds after a
successful entry is made. During this 15 seconds ANY key will
operate the opener.
Current Production Openers
1. Press and hold the program button until the round
LED turns blue, then
release.
PROGRAM
SET
+
PROGRAM
SET
+
2. The round LED will go out and the long LED will begin
ashing purple.
3. Return to previous
STEP.
PRGM
SET
TYPE 1 TYPE 2 TYPE 3
There are 4 types of programming button pads. Type 1
is shown in these steps. All buttons perform the same
function and programming is the same for all types shown
above.
Place operator into programming mode: TYPE 1-2-3-4
Openers manufactured between 1995 to
2011 and all external receivers
RADIO
SIGNAL
LEARN
CODE
CODE
LEARN
SET
SET
OPEN
FORCE
CLOSECODE
LEARN LIMITMANUAL
or
RADIO
SIGNAL
LEARN
CODE
RADIO
SIGNAL
LEARN
CODE
1. Press & release Learn Code button once. The red LED
will begin to ash.
Place operator into programming mode:
NOTE: Learn Code Buttons are normally located under lens
covers on earlier models.
PUTTING OPENER INTO PROGRAMMING MODE:
NOTE: The openers LEARN LED will time
out in 30 seconds. Programming must be
completed within 30 seconds.
-OR-
PROGRAM
SET
+
PROGRAM
SET
+
2. Return to previous STEP.
REPLACING BATTERIES
Scan this code with a QR code reader app
on a smart device to view a video of these
instructions or visit www.geniecompany.com
STEP 2) CHANGING THE FACTORY DEFAULT PIN OF 3-5-7:
1. Enter the factory default pin of 3-5-7.
2. Press PROGRAM key once.
3. Enter a new PIN of your choice (3-8 digits).
4. Press PROGRAM key once.
• Your PIN has been changed and your previous PIN will no
longer operate the keypad or opener.
STEP 3) OPTIONAL:
PROGRAMMING THE KEYPAD FOR MULTIPLE OPENERS (UP TO 3)
Whether the keypad is brand new or you are just adding
additional openers to an existing keypad, this STEP assumes
that STEPs 1 & 2 have already been completed.
Follow these steps to program opener 2 and/or 3 to the
keypad. (Only one PIN number can be used.)
1. Ensure the keypad back lighting is o.
2. Enter the current PIN.
3. Press PROGRAM key twice. LED will blink once per
second.
4. Enter total number of openers that keypad will be
operating (a total of “2” or “3” openers).
5. Press PROGRAM key once. LED will blink twice and shut
o.
•If LED did not blink twice and shut o, please see
RESETTING THE KEYPAD (FACTORY DEFAULT) section.
•THE KEYPAD IS NOW READY TO PROGRAM TO MULTIPLE
GARAGE DOOR OPENERS. CONTINUE WITH THE STEPS
BELOW.
PROGRAMMING TO MULTIPLE OPENERS CONTINUED
1. Ensure the keypad back lighting is o.
2. Place desired garage door opener (for door 2 or 3) into
PROGRAMMING MODE as shown to the right.
3. Enter the PIN number on keypad.
4. Press the UP/DOWN key once.
5. Press the number of the desired door (door 2 or 3).
6. Press the UP/DOWN key 3-4 times slowly until garage
door opener operates.
•Repeat steps 1 through 6 in this section to program
another door opener to this keypad (maximum of 3 doors
to 1 keypad).
•This completes programming of multiple doors. See STEP
4 MULTI-DOOR OPERATION for further instruction.
+
PRGM
SET
+
PRGM
SET
+
PRGM
SET
+
TYPE 4
STEP 1) PROGRAM THE NEW KEYPAD TO THE OPENER
The existing factory default Personal Identication Number
(PIN) for this keypad is the number sequence: 3-5-7
Sync the opener and the keypad by performing the
following:
1. Ensure the keypad back lighting is o.
2. Place garage door opener into PROGRAMMING MODE
as illustrated in the column to the right.
3. Press 3-5-7 in sequence on the keypad.
4. Press the UP/DOWN key 3 to 4 times slowly until
garage door opener operates.
•This completes the programming of a single door
opener (door 1) and keypad.
•IT IS RECOMMENDED THAT YOU CHANGE THIS PIN FROM THE
EXISTING FACTORY DEFAULT SETTING of 3-5-7. See STEP 2 below.
Activate keypad by opening battery compartment and
pull protective tab. Reinstall compartment door to begin
programming.

Summary of content (2 pages)