Product Instruction Product Name: ALL IN ONE Manual Version: V2.
Warning 1. The Device is not a medical device 2. Temperature accuracy is ±0.5° 3. The temperature threshold to define if an user has fever is set by SW to 37.5°. Make sure that the threshold is set correctly. 4. After reboot, wait 15min for Ambient temperature calibration of the device 5. The device works only in indoor or semi indoor environment. Avoid direct sunlight or rain 6. Elevated body temperature in the context of use should be confirmed with secondary evaluation methods (e.g.
Warning for Stand/Base 1. Please DO NOT stand on base 2. Please DO NOT touch the screen 3. We meet the 10°angle requirement for UL2361. If potentially forces above 50N will be applied on the device, the base has to be screwed into the floor. This is valid for all directions.
FCC WARNING Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Catalog 1. Safety instructions ..................................................................................... 5 2. Product overview ....................................................................................... 6 3. Performance Specifications ..................................................................... 8 4. Product List ................................................................................................. 9 5. Product structure ............................................
SAFETY INSTRUCTIONS Before using the device, please read and keep the following instructions for future reference. • Please follow the device’s user manual’s instructions. • Make sure that the local power supply meets the power requirements of the display. • Do not block the vent at the back of the monitor, and make sure there is enough space around the monitor to dissipate heat. • Do not open the cover. Damage caused by improper use is not covered by the warranty.
1 Product overview (Shown for reference, to correspond to the actual product Num kind) This product is a high-capacity exists for face recognition application process, high-performance, wide application, can be customized and so demand, the introduction of a hardware intelligent face recognition, face recognition algorithms can be combined, without the user together to achieve in vivo detection, face recognition dynamic, to provide users with a safe environment The product is based on Rockchip RK3399, dual
6 Environment 7 Stable Super strong environmental adaptability, under low light and strong backlight, it has a good performance. Android or Linux, server-level stability. 8 4G 4G module can be built in( optional) Dispark Provide SDK to meet the secondary development needs of SI / ISV vendors. 9 10 RF function WiFi: Frequency Range:2412Mhz~2462Mhz, 2412Mhz~2472Mhz maximum output power.0.035W Bluetooth: 5.0 Frequency Range: 2402Mhz~2480Mhz maximum output power.0.
3 Performance Specifications Classific ation Project Equipment shell Operating system Processor Internal storage Display Parameter Description Metal materials Android 7.1 RK3399 Dual Cortex-A72 + Quad Cortex-A53 Core Structure 64-bit CPU, 21.5 "resolution 1920*1080 Ethernet WIFI Interface Device host Working environment Optional Algorithm Upright Touch screen 16G 21.5"multi-point capacitive touch screen 10/100/1000Mbps Support Bluetooth V4.
4 Product List Serial numb er Content Quantity 1 Host *1 2 AC cable(Euro code & US Code) *2 3 WIFI antenna *1 4 Tray *1 5 Install the screw pack *4 6 Remote control *1 7 Keys *2 8 Operating instruction(Certificate of conformity, product warranty card) *1 9
5 Product structure (Structural Representation) Component number 1 Instructions AC110~240V Power input 2 WIFI antenna 3 RJ45 4 USB 5 Tray support 6 Capacitive touch screen 7 Thermal imaging sensor 8 Face recognition camera 9 Loudspeaker holes 10 Remote control receiving head 11 Position of hand 12 Sterilizing liquid outlet 13 Lock 10
14 Loudspeaker holes 15 Wall mounted panel 16 Reserved cable holes for access control, etc 11
6 Relay module specifications and operation instructions Module description: 1. The module adopts genuine high-quality 30A relay, with the maximum load of normally open interface: AC 250V / 30a, DC 30V / 30A; 2. It adopts SMD optocoupler isolation, strong driving ability, stable performance, trigger current 5mA; 3. Module working voltage 12V; 4. Module can set high level or low level trigger through jumper 5.
When there is no voltage at both ends of the relay coil or the voltage is insufficient, the common port (COM) of the relay is connected with the normally closed port (NC). When the voltage at both ends of the relay coil reaches the pull-in voltage, the common port (COM) of the relay is connected with the normally open port (NO). When the relay switch is closed, there is voltage at both ends of the device, which can work normally.
7 Operating instructions of sterilizer The induction spray sterilizer is an automatic spray sterilizer which adopts digital circuit control and infrared automatic induction. It has the advantages of stable and reliable operation, strong anti-interference ability of light source, sensitive induction, etc. Infrared automatic induction liquid, suitable for all kinds of disinfectant, alcohol, liquid medicine, hand sanitizer.
Use steps: 1. Open the bottle cap, import the disinfectant, alcohol, liquid medicine into the container, and close the bottle cap. The maximum capacity is 1000ml. 2. When the pump is used for the first time, press the pump head several times by hand to discharge the air in the pump body. 3. The indicator light is green, indicating the normal working state. 4. When using, put your hand within 8mm below the nozzle, the device will spray liquid once automatically, about 1ml each time.
8 Installation Notes Environmental requirements In the use of the product, we must strictly abide by the national and regional all-electric procedures. If the device is not working properly, do not disassemble repair yourself, otherwise it will affect the equipment warranty. Installation process to avoid extreme heat (or cold), high humidity, strong backlight, vibration, radiation, chemical corrosion and other harsh or extreme environments.
8.1 Stand installation (Installation effect diagram) The mechanical structure of the device has been considered in the design of vertical standing, so it is not necessary to make fixed points for standing. This installation method is used to control the turnstile. The access control cable can pass through the back of the device, open the device, and connect the access control cable to the relay. 8.2 Wall mounting 8.2.1 Installation location The installation position of the host equipment is Wall mounting.
8.2.
9 Remote control 19
10 Toxic and hazardous substances stated Part name Plu mbu m (Pb) Toxic and harmful substances or elements Mer Cad Chromi PBBS PBDE cury miu um VI m (Hg) (Cd) (Cr(VI)) (PBB) (PBDE) Shell 〇 〇 〇 〇 〇 〇 Circuit board and its components Power Adapter 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇 〇 This table is prepared according to SJ / T11364. Indicates that the content of the hazardous substance in all homogeneous 〇 materials of the component is below the limit specified in GB/T26572.
11 Warranty card Thank you for purchasing our company's products. In order to ensure the interests of our customers, if users purchase our products, if the product fails due to quality problems, they can contact the local dealer or special repair station with the invoice and warranty card. Warranty notice: 1.Within one year from the date of purchase, in case of failure under normal use, the company shall provide free warranty, parts replacement and other services according to the failure; 2.
Certificate Inspector: Production Date: