Installation Guide

Node B Installation Guide
Version 5.0.0 Page 26 of 37
Step 9 DC Power Connection
The power supply input must be a nominal -48Vdc input, with maximum 5amps.
The connection of the mains to DC supply is via screw terminals in the mains connection
block refer to the figure below. Removal of the protective safety cover (3 screws) is required
to gain access to the power terminals.
Below is the sequence to be followed for mains connection.

Cable preparation - Specification: terminal blocks maximum cable size 8AWG (Ø3.5mm
or 8.3mm
2
)

maximum size of outer diameter 7mm for overall screen of 2 core cable

Remove mains protective cover (3 screws) – see figure above

Remove blanking plug from right most position – see figure below

Feed cable thru cable gland nut, seal and cable gland

Insert cable into terminal block

Secure cable gland in base of Node B and tighen gland seal nut

Replace protective cover (3 screws)
Figure 6-14 : Power Connections
Cable gland
Gland seal
Conduit adaptor
Conduit adaptor
Terminal
Block

Summary of content (12 pages)