Operation Manual English Door control MiniMax 3 S EN conform: EN12453 (Safety in use of power operated doors)
Operation Manual English The door control DC MiniMax 3 S is designed for hold to run control of power operated doors. The basic version is designed for hold to run operation only, but it can be extended individually by an optional module. Safety Directions • In case of using DC MiniMax 3 S with a permanent mains connection, an all-pole main switch with an appropriate back-up fuse must be provided. • With three phase motor connection an external fuse in the main supply should be max. 10A delayed.
Operation Manual English Main board DC MiniMax 3S Klemmleiste Connector Motor+ +Safety Sicherheitskette Motor Switch (X2) Netzanschluss Mains supply (X1) PE Klemme supply Selector Spannungswahl voltage (X4) Connector External pushStecksockel für button station ext.
Operation Manual English 6 Main Board DC MiniMax 3S 4 5 S6 3 2 S9 S10 S8 S11 S12 S14 S16 5 J1 OPEN AUF X4 1 J4 2 3 X6 Selector mains supply Wahl der Netzspannung X4 230V 400V 1 2 2 3 S01 CLOSE ZU S02 X9 1 2 K3 J3 J2 2 X10 X8 J5 24V DC 50 mA S13 3 4 + 6 PE X7 - 7 8 L3 L2 L1 X1 9 10 11 12 13 14 15 W V U Zuleitung 230V / 50Hz Mains Zuleitung 400V / 50Hz supply S5 1 X5 4 M Motor 230 V / 50Hz Motor 400 V / 50Hz S2 1 S4 X3 S3 X2 F2 5 S7 S15
Operation Manual Labels F2 K1 K2 K3 M1 S01 S02 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 Thermal protection Contactor Close Contactor Open Traffic Light Motor connection Installation switch Open Installation switch Close Aux. limit switch Open Limit switch Open (NC) Safety limit switch Open (NC) Safety limit switch (NC) Limit switch Close (NC) Aux.
Operation Manual English Wiring Diagrams 15 STOP 14 13 8 11 CLOSE 10 9 Brown / +12V 8 Green / Signal 7 White / GND 6 - 5 + 3 2 1 9 OPEN 12 4 Electrical Safety edge 1 8k2 7 DIP Switch 1 ON Pro-Sec-O* OSE* 24 V DC Pneumatic Safety edge IMPULSE* Photobeam* 9 8 Not connected 8k2 7 DIP Switch 1 and 2 ON X3 2 Not connected Relais output* for traffic light or courtesy light X9 * only possible, if comfort module is used
Operation Manual English Jumper settings J4 Stecksockel für Ext. 3- fach Taster Connector external push button station - wird der Steckplatz nicht belegt, muss der if not used, J4 has to be bricked X6 Jumper 4, gesteckt sein. ZU AUF STOP CLOSE OPEN STOP J3 Stecksockel für Spiralkabel Connector spiral cord - wird der Steckplatz nicht belegt, muss der if not used, J3 has to be bricked Jumper 3, gesteckt sein.
English Operation Manual Comfort module Comfort-Module
Operation Manual English Installation • • Plug in the board into the connector X7 Plug in Jumper J2 on connector X10 Functionality Opto-electronical safety edge e.g.
Operation Manual English 1 The testing of the pneumatic safety edge takes place in the lower door position. Please ensure that the safety edge is activated in the lower door position. The Aux. Limit switch Close has to be used. 2 2 minute night light period is activated by every movement of the door. If the prewarning is activated, the courtesy light starts 5 seconds before the door movement. 3 Red traffic light with prewarning - prewarning 3 sec. flashing before automatic closing - prewarning 3 sec.