GE Inspection Technologies Remote Visual Inspection ELSV-60 Solarc Light Source ® Operating Manual www.ge.
ELSV-60 Light Source What You Have Received Thank you for purchasing the ELSV-60 Solarc® Hi-Lux Light Source. This product was manufactured for GE Inspection Technologies by Welch Allyn Inc., our parent company and technology leader in the design and manufacture of advanced technology lighting products. By following the use and care instruction in this guide, you will be rewarded with years of dependable, trouble-free service. Please read these instructions completely before use.
ELSV-60 Light Source System Symbol Description Caution: Refer to User’s Manual Caution: Hot Surface Replace Fuse as Marked: Warning: Type F, 250V, 2A High Voltage is Present Symbol in Electrical Rating Signifies AC Mains Power Symbol on Power Switch Indicates Power is On When Depressed Symbol on Power Switch Indicates Power is Off When Depressed Protective Earth Ground Equipotential with Ground High Intensity Light www.ge.
ELSV-60 Light Source Warning and Precautions DIRECT VIEWING OF EXITING LIGHT CAN BE HARMFUL! The light at the front of the light source and at the tip of a connected fiber-optic bundle is of high intensity and can result in very high temperatures. To minimize the risk of injury, avoid direct viewing of the light or contact with surrounding surfaces. Light includes UV wavelengths which may cause skin or eye irritation from direct exposures exceeding 15 min./day.
ELSV-60 Light Source AVERTISSEMENTS ET PRECAUTIONS L’intensité lumineuse du générateur de lumière et à l’extrémité du guide de lumière, induit unc température élevée et une forte luminosité. Pour minimiser les risques de blessures, éviter tout contact direct avec les yeux et la peau. Afin d’empêcher un aveuglement temporaire et toute brûlure, ilest recommandé de connecter le guide de lumière au générateur avant la mise en marche de ce dernier.
ELSV-60 Light Source System Description The ELSV-60 Hi-Lux Light Source provides high quality, white light for industrial borescope and fiberscope inspections. It incorporates a patented and field-proven lamp technology that has much greater efficiency than halogen or xenon lamps when transferring light into a small fiber bundle, such as that found in borescopes and fiberscopes. This greater efficiency allows the lamp to run at only 60W, which then enables a small and lightweight light source design.
ELSV-60 Light Source System Setup and Operation CAUTION: 1. Verify that the supply voltage is within the 100-240VAC range specified for this product. 2. To prevent temporary blinding, insert light guide into socket before turning power ON. 3. The light guide tip and light source socket will be hot when light guide is removed. CONTROLS & PORTS ON/OFF Switch A two position rocker switch is used to turn the unit on or off.
ELSV-60 Light Source System Setup and Operation (continued) Setup 1. With the power switch in the OFF position, plug the AC power cord into the power input port on the back of the unit and then into a grounded receptacle. 2. Plug a light guide with appropriate adapter installed into the light exit socket. Note: The light guide is fully inserted when the light guide spring snaps into the groove cut into the socket. 3. Turn the power switch ON and wait 15 seconds for the lamp to complete the warm-up cycle.
ELSV-60 Light Source System Setup and Operation (continued) Continue with steps 5 & 6 if you are using the BCAM 1000 C-Mount Video Camera 5. Connect the BCAM power/video cable from the camera to the VIDEO IN CAMERA port on the light source front panel. 6. Connect a video cable from either the S-Video or composite video-out port on the light source front panel to a monitor or video recording device.
ELSV-60 Light Source User Maintenance Lamp Replacement CAUTION: Lamp may be Hot! Allow the lamp to cool before replacing. NOTE: Use only GE Inspection Technologies replacement lamp SPL-600. AVERTISSEMENT: Pour eviter les rique d’incendie. Utiliser une Lampe de rechange a GE Inspection Technologies SPL-600. DO NOT touch the lamp itself or the interior reflective surface, because skin oils will cause premature lamp failure. If necessary, clean fingerprints with an alcohol dampened cotton swab.
10 ELSV-60 Light Source User Maintenance (continued) FUSE REPLACEMENT 1. Fuse replacement must be completed with power cord disconnected. 2. Fuses are present in fuseholder. Use the same type, same rated fuse as marked and specified to avoid risk of fire hazard. Fuse CLEANING WARNING: Prior to cleaning, turn power switch OFF and disconnect the power cord from both the wall outlet and light source.
ELSV-60 Light Source 11 Troubleshooting Guide SYMPTOM PROBABLE CAUSE SOLUTION • Lamp is not illuminating and fan is operating. • Lamp was not given adequate time to “cool down” before restarting. • Turn unit off and wait 20 seconds before turning back on. • Light Source has overheated. • Verify environmental temperature does not exceed specifications and allow to cool down for 10 minutes. Check to ensure vents and fan exhaust are not obstructed. • Lamp has burned out.
12 ELSV-60 Light Source Technical Specifications Power In 100-240VAC, 50/60 Hz, 2.0A (@ 120VAC) Fuse Set 2 each 2.0A 250V Type F (Fast Acting) Dimensions 23 x 23 x 9.3 cm (9.0 x 9.0 x 3.7 in.) Weight 2.42 kg (5.3 lbs.
ELSV-60 Light Source 13 Agency Compliance Statements This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Class A Compliance Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
14 ELSV-60 Light Source Warranty GE Inspection Technologies warrants the ELSV-60 Light Source to be free of defects in material and workmanship and to perform in accordance with the manufacturer’s specifications when subject to normal use and service for a period of one year from the date of purchase. GE Inspection Technologies will either repair or replace components found to be defective or at variance from the manufacturer’s specifications within this time at no cost to the customer.
ELSV-60 Light Source 15 Environmental Compliance The equipment that you bought has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems.
16 ELSV-60 Light Source Service Contact Information USA GE Inspection Technologies Product Service Dept. 4619 Jordan Road North Dock Skaneateles Falls, NY 13153 Germany GE Inspection Technologies Lotzenäcker 4 72379 Hechigen Hong Kong GE Inspection Technologies Unit 1602, 16/F Sing Pao Building 101 King's Road North Point, Hong Kong Tel: 315-685-4142 Fax: 315-685-2920 Email: rvi-service@ge.com Tel: +49-7471-9882 20 Fax: +49 7471-9882 30 Email: rvi-infoeuropa@ge.
Customer Support Centers North/South America 4619 Jordan Road Skaneateles Falls, NY 13153 Tel: 888-332-3848 315-685-4142 Email: rvi-info@ge.com Europe Lotzenäcker 4 72379 Hechingen Germany Tel: +49 (0) 7471 9882 0 Email: rvi-infoeuropa@ge.com Asia/Pacific Unit 1602, 16/F Sing Pao Building 101 King’s Road North Point Hong Kong Tel: +852 2877 0801 Email: rvi-infohongkong@ge.com www.ge.com/inspectiontechnologies ©2007 General Electric Company. PowerBar is a trademark of GE Inspection Technologies, LP.