Installation Guide






This luminaire is designed for outdoor applications and must
adhere to 25°C (77°F) maximum ambient temperature limitation.
Make all electrical connections in accordance with the National
Electric Code and any applicable local code requirements.



 Turn power o before servicing
see instructions


 Follow installation instructions
1. Place unit on 3” diameter x 3” long tenon.
2. Torque set screws to 10-12 ft-lbs.

1. Remove globe by rotating counter-clockwise approxi-
mately 90° and raising o locking ring (see Figure 1)
2. Install lamp (see Lamp Section).
3. Access to optional internal louver/shielding is available
with globe removed. Orient shielding such that light
blocked in direction intended.
4. Replace globe by lowering into locking ring and rotating
90° clockwise. Verify that orientation of globe is correct.
For proper orientation, see “Street/house side” label on
globes so equipped.
5. Install set screws (found in pack) for tamper resistant or
2G applications.



1. Rotate globe
Set screw
(4 places)


 Wear safety glasses and gloves
during installation and servicing
g
GE
Lighting Solutions
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered suciently for the purchaser’s purposes, the matter should be referred to
GE Lighting Solutions.

Summary of content (2 pages)