Dimensions Guide

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
PTS9200SN
GE Profile
30" Smart Built-In Twin Flex Convection Wall Oven
For answers to your Monogram, GE Café
, GE Profile
or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.
Listed by
Underwriters
Laboratories
Specification Revised 7/20
MOST 30" WALL CABINETS CAN BE USED
WITH THIS UNIT.
APPROVED INSTALLATIONS: Above Warming
Drawer, Below Built-in Microwave or Advantium
®
,
Side-by Side, and Under Counter
NOTE: These ovens are not approved for stacking
one single wall oven over another single wall oven.
Cabinets installed adjacent to wall ovens must have an
adhesion spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets
and drawers on adjacent 45° and 90° walls should be
placed to avoid interference with the handle.
Side-by-side installations require two ovens in
separate cutouts and at least 2" between cutouts.
Approved cooktops for installation above this wall
oven: CHP9536, PHP9036, CHP9530, PHP9030,
JP3536, JP3036, JP3530, JP3030
IMPORTANT: Electric wall ovens are not approved
for installation with a plug and receptacle. They
must be hard wired in accordance with installation
instructions.
IMPORTANT: Before installing, consult installation
instructions packed with product for
current dimensional data.
NOTE: If the cabinet in which the wall oven is
installed does not have a solid bottom, two braces or
runners must be installed to support the weight of the
oven. The runners and braces must support up to 400
lbs (181 kg).
KW R ATING
240V 4.2
208V 3.2
BREAKER SIZE
240V 20 Amps
208V 20 Amps
Junction Box
Location, Right
Hand Side Only
(may be located in
Adjacent Cabinet)
22" (55.9 cm) min.
to Bottom of
Junction Box
Cutout Depth
23-1/2" (59.7 cm) min.
Open Door Clearance
15" (38.1 cm) min.
NOTE: Opening
Between Inside
Walls Must be at
Least
28-1/2"
(72.4 cm) wide
NOTE: Allow
1/4" (0.7 cm)
clearances from
side edges of
oven door
Junction Box Location
9-1/2" (24.1 cm) max.
Recommended Cutout
Location from Floor
26-1/2" (67.3 cm) max.
28-5/8" (72.7) max.
28-1/2" (72.4) min.
1" (2.4) min.
Top Clearance
for Wall Oven
Beyond Cutout
1-1/4" (3.2) min.
Bottom Clearance
for Wall Oven
Beyond Cutout
Cutout Width
Cabinet Width
27-5/16" (69.4) max.
27-1/4" (69.2) min.
Cutout Width
26-1/2" (67.3)
Suggested Cutout
Location from Floor
31-1/4" min.
From top surface
of countertop to
top surface of
wall oven support
platform
2-1/2" min.
From front surface
of cabinet to front edge
of cooktop cutout
30"
Center Line Center Line
11/16" (1.8) min.
Clearance for Wall
Oven Beyond
Cutout, Both Sides
Cutout - observe
all dimensions and
requirements
Cutout - observe
all dimensions and
requirements
30-1/2" (77.5) min.
30" models
2" (5.1) min.
Junction Box
Location, Right
Hand Side Only
(may be located in
Adjacent Cabinet)
22" (55.9) min.
to Bottom of
Junction Box
23-1/2" (59.7) min.
Cutout Depth
15" (38.1) min.
Open Door Clearance
NOTE: Opening
Between Inside
Walls Must be at
Least
28-1/2"
(72.4) wide
NOTE: Allow
1/4" (0.7)
clearances from
side edges of
oven door
9-1/2" (24.1) max.
2-1/2" MIN
From front edge
of countertop to front
edge of cooktop cutout
31-1/4" MIN
From top surface
of countertop to
top surface of
wall oven support
platform
INSTALLATION ABOVE A WALL OVEN
INSTALLATION BELOW A COOKTOP
28-1/8"
26-3/4"
29-3/4"
41-3/4"
Conduit
48"

Summary of content (2 pages)