Installation instructions

11
1. Press the clip end of the grease cup holder into the
center hole on the grill bottom. It should hang
snugly in place.
2. Snap a clean empty can into the ring. A can with
ribbed sides is best so that it stays securely in place.
HANG THE GREASE CUP HOLDER
17
Grease Cup
Holder
Can
(not included)
1. Remove the plastic cover from the LP
tank connector.
2. Screw the regulator coupling (on the gas hose)
onto the LP tank connector in a clockwise direction.
Hand tighten only.
NOTE: The regulator coupling tightens clockwise
and will not allow gas to flow unless the connection
is tight. The connection requires tightening by
hand only.
WARNING: Do not use a wrench to tighten
the connection. Using a wrench could damage the
regulator coupling and could cause a gas leak. The
regulator vent holes should be at 3 o’clock (facing
forward). They should not be pointed up.
CONNECT THE LP TANK
15
Regulator
(vent holes
at 3 o’clock)
LP Tank
Connector
Regulator
Coupling
Assembly Instructions
Read your Owner’s Manual carefully for proper use
and care of your grill.
READ YOUR OWNER’S MANUAL
18
TO TEST FOR LEAKS:
Prepare a soap solution of one part water, one part
liquid detergent.
1. Extinguish any open flame or cigarettes in the area.
2. Make sure the LP tank valve is closed and the grill
controls are turned to OFF.
3. Connect the LP gas tank. See the CONNECT THE
LP TANK step.
4. With a full LP tank, open the tank valve slowly.
TEST FOR LEAKS
16
WARNING —A complete gas tightness
check must be performed at the final use site.
DO NOT use grill until all connections have been
leak tested.
5. Wet each connection with the soap solution.
6. A leak is identified by a flow of bubbles from the
area of the leak.
7. If a leak is detected, close the LP tank valve, tighten
the connection, and retest (Steps 4–6).
8. If you smell gas, read and follow the complete Leak
Test section in the Owner's Manual.
9. If the leak persists, contact your grill dealer for
assistance. Do not attempt to operate the grill
if a leak is present.
TEST FOR LEAKS (CONTINUED)
LP Tank Connection