Product Manual
Table Of Contents
- Vivid™ E80 / Vivid™ E90 / Vivid™ E95
- Table of Contents
- Chapter 1
- Introduction
- Chapter 2
- Site Preparations
- General Ultrasound system requirements
- Facility needs
- Environmental Dangers
- Chapter 3
- System Setup
- Setup reminders
- Receiving and unpacking the equipment
- Packing materials - recycling information
- Preparing for setup
- Completing the setup
- Configuration
- Connectivity overview
- Connectivity setup
- Product Locator Installation Card
- Chapter 4
- General Procedures and Functional Checks
- Chapter 5
- Components and Functions (Theory)
- Software overview
- InSite ExC
- Vivid E80/E90/E95 overview
- Top Console with LCD monitor and Operating Panel
- Main Console
- Air Flow control
- Casters and brakes
- Front End Processor (FEP)
- Back End Processor (BEP)
- Power distribution
- Input and Output (I/O) modules
- Restart Vivid E80/E90/E95 after diagnostics
- Chapter 6
- Service Adjustments
- Chapter 7
- Diagnostics/Troubleshooting
- Chapter 8
- Replacement Procedures
- Warnings and important information
- Loading the software
- Replacing covers and bumpers
- LCD Monitor and LCD Arm parts replacement
- Upper OP Panel/Touch Panel Assembly replacement
- Lower Operating Panel Parts replacement
- A/N Keyboard parts replacement
- Other Top Console Parts replacement
- Replacing XYZ Parts
- Main Console parts replacement
- Casters and Brakes replacement
- Front End Processor (FEP) / Card Cage parts replacement
- Back End Processor (BEP) parts replacement
- Main Power Supply replacement
- Patient I/O assembly replacement
- Peripherals replacement
- Cables replacement
- Chapter 9
- Renewal Parts
- List of Abbreviations
- Software for Vivid E80/E90/E95
- Covers and Bumpers
- Top Console parts
- XYZ parts
- Main Console parts
- Casters (wheels) parts
- Front End Processor (FEP) Card Rack parts
- Back End Processor (BEP) parts
- Main Power Supply
- I/O modules parts
- Peripherals for use with Vivid E80/ E90/E95
- Mains power cables - Vivid E80/E90/ E95
- Internal Cables - Vivid E80/E90/E95
- ECG cables - Vivid E80/E90/E95
- Physio TX parts
- Probes for Vivid E80/E90/E95
- Options - Vivid E80/E90/E95
- Chapter 10
- Care and Maintenance
- Index
Diagnostics/Troubleshooting
7-4 Vivid E80/E90/E95 – Service Manual
GC091052
Rev. 3
Collect a ‘trouble image’ with logs
If the Ultrasound system should malfunction, press the Alt+D
keys simultaneously. This will collect a screen capture of the
monitor, system presets and several log files in a date and time
stamped “.zip” file.
NOTE: This function may also be used to make a Print Screen (screen
dump).
The Alt+D function is available at all times.
When Alt+D is pressed, a menu box appears that allows for;
• a place to enter a description of the issue
• a check box to indicate a Ultrasound system lockup
• a choice to Export to a pre-formatted removable media or
save to the Export directory D: drive (for remote viewing
through InSite).
NOTE: You MUST select one of the available devices as the destination
device if it is to be different than the default Export directory on
the hard drive.
The screen capture is a bitmap which eliminates the possibility
of artifacts from compression.
Figure 7-1. System problem reporting (ALT+D dialog box)
1. Type description of issue here
2. Select if you’ve had a system
lockup (after restart)
3. Select where to store the report
4. Select this button when ready to
Save and Export
5. Progress bar
6. See: ‘Advanced log options’ on
page 7-5.
7. See: ‘Advanced log options’ on
page 7-5.
8. Exit