Brochure

VRF
COMMERCIAL AC DUCTLESS
WATER HEATERS WATER TREATMENT
ROOM AC
SPECIFICATIONS
See pages 105-106 for warranty information.
geappliances.com
135134
See page 106 for warranty information.
134
Above illustrations intended for dimensional reference only.
Refer to photography for actual product appearance.
GE BUILT-IN ROOM AIR CONDITIONERS WALL OPENING
FOR WHITE RAB26 AND BEIGE RAB46B QUICK SNAP CASES
WALL OUTLETS
All wiring, including in stallation of receptacle, must be made in
accordance with local elec trical codes and regulations. Electrical
outlet should be in reach of line cord.
Note: Aluminum wiring may pose special problems —consult a
qualified electrician.
Note: Some models may not be available in your area due to
local legislation. Contact your local dealer.
OPENING FOR WALL SLEEVE
RAB26A
A finished opening of 26-1/8" x
15-3/4", clear of intrusions, is required.
Keep clearance of 4" from side walls.
Brick veneer or frame walls should
have wood studding surrounding case
to provide firm anchoring with screws.
Case can be fastened
directly to brick or block walls with
screws sunk in lead expansion shields.
Note: Units should be caulked on
all four sides of case to the building
exterior to assure building integrity.
RAK26TO
ADDITIONAL PANELS FOR 26"
SLEEVE TENANT OPTION
Used when the air conditioner is
offered as a tenant option
Install when wall sleeve is installed
without a chassis to close off the
interior from outside elements
Includes indoor steel insulated panel,
vinyl outdoor panel and hardware
STANDARD WALL CASE
RAB26A—Color matched white
sleeve to current AJ product.
4-piece quick snap universal design.
Aluminum grille (RAG13A) included.
Uses RAD10 drain kit.
RAB46BBeige colored Quick
Snap Flat
Pack Wall Sleeve
Parallel
115V
15 Amp
Tandem
230/208V
15 Amp
Perpendicular
230/208V
20 Amp
GE AZ95 SERIES
COOLING WITH ELECTRIC HEAT
AZ95E09DAC AZ95E12DAC AZ95E18DAC
Voltage 230/208 230/208 230/208
CASE DIMENSIONS
Cooling BTUH 9,200 11,500 17,20 0
EER (Minimum) 11.5 12.1 11.2
Cooling power (W) 795 940 1,520
Cooling current (A) 3.6 4.3 7.3
Sensible heat ratio (SHR) 74% 73% 70%**
Dehumidification (Pints per Hour) 2.2 2.8 4.7**
Refrigerant R-410A R-410A R-410A
Indoor CFM (hi/lo) (0.1 ESP) 408/305 408/356 46 8/408
CASE DIMENSIONS
Width (in.) 23-5/8 23-5/8 23-5/8
Depth (in.) 24-1/8 24-1/8 24-1/8
Height (in.) 31-7/8 31-7/8 31-7/8
Net weight (lbs.) 119 127 141
Approx. shipping weight (lbs.) 132 140 154
Clearances for front install (min.) 3" on all sides 3" on all sides 3" on all sides
Clearances for side install (min.) 5" on front/3" on sides 5" on front/3" on sides 5" on front/3" on sides
GE AZ95 SERIES
HEAT PUMP WITH BACKUP ELECTRIC HEAT HEAT PUMP WITH BACKUP ELECTRIC HEAT
AZ95H09DAC AZ95H12DAC AZ95H18DAC AZ95H09EAC AZ95H12EAC AZ95H18EAC
Voltage 230/208 230/208 230/208 265 265 265
FEATURES
Cooling BTUH 8,900 11,300 17,000 8,700 11,400 17,100
EER (Minimum) 11.1 11.8 11.1 11 11 11
Cooling power (W) 800 955 1,525 775 925 1,560
Cooling current (A) 3.7 4.5 7.1 3 4 6.3
Sensible heat ratio (SHR) 76% 75% 71%** 75% 76% 75%**
Dehumidification (Pints per Hour) 1.9 2.5 4.4** 1.9 2.5 4.4**
Refrigerant R-410A R-410A R-410A R-410A R-410A R-410A
Indoor CFM (hi/lo) (0.1 ESP) 408/305 417/376 46 8/408 408/305 417/376 468/40 8
HEAT PUMP
Heating BTU 8,500 10,500 15,800 8,000 10,500 15,900
COP (Min.) 3.3 3.5 3.3 3.3 3.5 3.3
Heating power (W) 735 870 1,400 660 865 1,435
Heating current (A) 3.5 4.3 6.6 2.8 3.7 5.9
CASE DIMENSIONS
Width (in.) 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8 23-5/8
Depth (in.) 24-1/8 24-1/8 24-1/8 24-1/8 24-1/8 24-1/8
Height (in.) 31-7/8 31 -7/8 3 1-7/8 31-7/8 31 -7/8 31 -7/8
Net weight (lbs.) 122 128 142 122 128 142
Approx. shipping weight (lbs.) 135 141
155 135 141 155
Clearances for front install (min.) 3" on all sides 3" on all sides 3" on all sides 3" on all sides 3" on all sides 3" on all sides
Clearances for side install (min.) 5" on front/3" on sides 5" on front/3" on sides 5" on front/3" on sides 5" on front/3" on sides 5" on front/3" on sides 5" on front/3" on sides
*230V Performance Data Listed
**18K Dehum Rate and SHR data acquired using medium fan speed. All other models show low fan speed data.
HOTPOINT 230/208V
COOLING WITH ELECTRIC RESISTANCE HEAT
AH11E07D2B AH11E07D3B AH11E09D2B AH11E09D3B AH11E12D3B AH11E12D5B AH11E15D3B AH11E15D5B
Voltage 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208
COOLING CAPACITY
Cooling BTUH 7,200/7,000 7,20 0/7,20 0 9,000/8,800 9,200/9,000 12,000/11,800 12,000/11,800 14,500/14,400 14,500/14,400
EER (BTU/Watt) 11.9 11.9 11.3 11.3 10.7 10.7 9.7 9.7
Heater Watts 2,500/2,050 3,500/2,900 2,500/2,050 3,500/2,900 3,500/2,900 5,000/4,090 3,500/2,900 5,000/4,090
Total Electric heating watts 2,535/2,080 3,535/2,900 2,535/2,080 3,535/2,900 3,535/2,900 5,034/4,125 3,535/2,900 5,035/4,125
FEATURES
Refrigerant type R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Electronic controls
LCDI power cord
Remote thermostat capable
Slide-in chassis
Discharge grille 1-position 1-position 1-position 1-position 1-position 1-position 1-position 1-position
Fan motor 2 2 2 2 2 2 2 2
Fan speeds 3 3 3 3 3 3 3 3
Heat - Cool
Rotary compressor
Fan cycle control
Freeze control
Automatic indoor frost control
Auto power recovery
Central desk control capable
Fresh air vent Concealed Manual Vent Control / Vent Air Filter
WEIGHT & DIMENSIONS
Overall dimensions
(including room cover) (WxHxD) 42 x 16 x 21
Net weight 102 lb 102 lb 98 lb 105 lb 109 lb 109 lb 113 lb 113 lb
Approximate shipping weight 112 lb 112 lb 109 lb 130 lb 120 lb 120 lb 123 lb 123 lb
HOTPOINT® COOL SERIES
Built-in RAC Installation
(Pub. 1-G003 pg. 138) April 30.1993
Make frame if desired or caulk
between case and siding
15-3/4
26-1/8
Frame Construction
Brick Block and Brick
Frame Construction
Fill open cells
with mortar
or insulation
15-3/4
26-1/8
Lintel
Lintel
OUTSIDE INSIDE
16-7/8
Caulking
Drip Rail
Trim Molding
(if desired)
Plaster Line
Built-In Room Air Conditioners
Wall Opening for RAB36/37/38 Case
A finished opening of 26-1/8" x 15-3/4", clear of
intrusions, is required. Keep clearance of 4" from
side walls. Brick veneer or frame walls should have
wood studding surrounding case to provide firm
anchoring with screws. Case can be fastened directly
to brick or block walls with screws sunk in lead
expansion shields.
Flexible Mounting Position
64” 230V 44”
72” 115V 50”
Lin
e cord
Line cord
Maximum Cord
Set Extension
16-3/8"
26"
15-5/8"
APPLICATIONS