Brochure

geappliances.com
98
VRF
COMMERCIAL AC DUCTLESS
WATER HEATERS WATER TREATMENT
ROOM AC
SPECIFICATIONS
ZONELINE® ULTIMATEV10
TM
VERTICAL AIR CONDITIONERS ZONELINE ULTIMATEV10 VERTICAL AIR CONDITIONERS
ZONELINE ULTIMATE V10 VERTICAL AIR CONDITIONERS
AZ95E09DAC
AZ95E12DAC
AZ95E18DAC
9,200/11,500/17,200 BTU (Cool)
11.5/12.1/11.2 EER
230/208 Volts
AZ95H09DAC
AZ95H12DAC
AZ95H18DAC
8,900/11,300/17,000 BTU (Cool)
8,500/10,500/15,800 BTU (Heat)
11.1/11.8/11.1 EER
3.3/3.5/3.3 COP*
230/208 Volts
AZ95H09EAC
AZ95H12EAC
AZ95H18EAC
8,700/11,400/17,100 BTU (Cool)
8,000/10,500/15,900 BTU (Heat)
11.0/11.0/11.0 EER
3.3/3.3/3.3 COP*
265 Volts
ESSENTIAL ACCESSORIES
Zoneline Vertical Air Conditioners require a set of essential accessories for proper operation.
Once you have selected the size of unit needed, next you’ll need to consider the following:
POWER CONNECTIONS - All AZ95 Zoneline Vertical units must be direct connected
POWER CONNECTION REQUIREMENTS (RESISTANCE HEAT)
POWER CONNECTION REQUIREMENTS (RESISTANCE HEAT)
RAK315D/320D/330D
RAK320D SHOWN
230/208-Volt Universal
DIRECT CONNECT
Power Supply Kit
RAK515D/520D/530D
RAK520D SHOWN
265-Volt Universal
Direct connect
Power Supply Kit
230/208 VOLT 9,000/12,000 BTUh 18,000 BTUh*
POWER
CONNECTION KIT
RAK315D RAK320D RAK330D RAK320D RAK330D
Heater BTUh 8360/6838 11770/9629 17060/13952 11770/9629 17060/13952
Total Watts 2568/2122 3568/2940 5118/4207 3568/2940 511 8/4207
Heater Watts 2450/2004 3450/2822 5000/4089 3450/2822 5000/4089
Total Heating Amps 10.7/9.6 15/13.6 21.7/19.7 15/13.6 21.7/19.7
MCA
15
20 30
20 30
Recommend
Protective Device
(MOCP)
15 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
265 VOLT 9,000/12,000 BTUh 18,000 BTUh*
POWER
CONNECTION KIT
RAK515D RAK520D RAK530D RAK520D RAK530D
Heater BTUh 8360 11770 17060 11770 17060
Total Watts 2568 3568 5118 3568 5118
Heater Watts 2450 3450 5000 3450 5000
Total Heating Amps 9.2 13 18.9 13 18.9
MCA
15
20 30
20 30
Recommend
Protective Device
(MOCP)
15 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
The correct kit for the installation is determined by the voltage and breaker size of the electrical circuit.
*There is no 15 amp breaker option available for the 18,000 BTUh models due to compliance with UL.
Complete features and specifications on page 135
IMPORTANT NOTICE
Equipment used as a primary source for heating or cooling is an integral part of the building in which it is installed.
Proper application is essential for satisfactory performance over a wide range of operating conditions.
It is strongly recommended that a professional engineer determine proper application.
If this unit is a replacement unit, its specifications and performance may dier from those of the unit it is replacing.
For that reason, we again strongly recommend that a professional engineer determine proper application.
SYSTEM ESSENTIAL
COMPONENTS
• Drain Platform (RAVDPLAT)
• Wall plenum
• Exterior grille
• Chassis
• Drain connections
• Remote thermostat
• Return air grille
• Ductwork (field supplied)
Supply register (field supplied)
Access panel or door
• Platform Legs (field supplied)
SYSTEM FEATURES
The Zoneline UltimateV10 Single Packaged Vertical air
conditioner is designed with features and innovations
making it the ideal unit to own.
• Excellent eciency and dehumidication
• Permanently lubricated fan motors
• Standard size air filter (18” x 20” x 1) included
• Central desk control capability
HI and LOW fan speeds controlled by remote thermostat
• Corrosion protection treatment standard
• Slinger ring condensate removal
• Indoor frost control
• Automatic compressor random restart
• Compressor restart delay
• Electronic control diagnostics/Service Models
• Warranty (including both parts and labor)
• Boost Heat
• Freeze/Heat Sentinel
• Auxiliary Control Settings
ZONELINE ULTIMATEV10
AIR CONDITIONER