Installation Guide

1
6
3
3
Cut the appropriate size hole into
ceiling tile (see table at right).
Slide reector into the xture.
Verify reector trim is ush with
ceiling. Repeat Step 4 if trim is
not ush.
For wall wash reectors, position
reector so that light is directed
towards wall.
Option A: Mount xture by
attaching hanger bars to
T-Grid ceiling (BH3 SKU 94890).
Unit Installation
5
Dust off any particles that may
have adhered to connection
points and heat sink during
installation process with a dry
cloth or compressed air. Twist
Infusion™ downlight module
into holder.
Option B: Mount xture with ½”
EMT conduit.
Note: Supplied by 3rd party.
Slide hanger bars through
adjustable mounting brackets.
Adjust xture height to be
ush with ceiling and secure
by tightening both adjustable
mounting bracket wingnuts.
2
4
T-Grid T-Grid
Fixture Hole Size
4 in. round xture 5 in. (126mm) diameter hole
6 in. round xture 6½ in. (165mm) diameter hole
4 in. square xture 5½ in. x 5½ in. (140mm x 140mm)
6 in. square xture 7 in. x 7 in. (178mm x 178mm)