Data Manual

8
RESISTANCE HEAT HEAT PUMP
AZ45 SERIES AZ45 DRY AIR 25 AZ65 SERIES
Cooling EER range (230 Volts/265 Volts) 10.5 - 13.4 11.0 - 12.8 10.3 - 13.0
Heating COP range (230 Volts/265 Volts) N/A N/A 3.2 - 4.0
Refrigerant type R-410A R-410A R-410A
Cross-flow (tangential) blower Standard Standard Standard
Enhanced dehumidification Optional Standard
Sound deadening mastic Standard Standard Standard
Composite (non rustable) basepan Standard Standard Standard
Heat pump with resistance heat back-up Standard
Heat pump with supplemental
resistance heat (Boost heat)
Selectable
Staged heating 3-Stage***
Universal heaters—UPC** Standard Standard Standard
Touch-pad controls with white LEDs Standard Standard Standard
Auto dimming display Standard Standard Standard
Auxiliary control features Standard Standard Standard
Electric resistance heat lock-out (above 46°F) Standard
Automatic emergency heat Standard Standard Standard
Heat pump defrost system Reverse cycle
Quick heat recovery Standard
Separate indoor & outdoor DC
motors — permanently lubricated
Standard Standard Standard
2-speed outdoor fan Standard Standard Standard
Indoor fan speed settings Hi/Low Hi/Low Hi/Low
“SmartFan” fan cycle control Standard Standard Standard
Auto power recovery Standard Standard Standard
Automatic compressor restart delay Standard Standard Standard
Freeze Sentinel (41°F) Standard Standard Standard
Heat Sentinel (8F) Standard Standard Standard
Low Ambient Lockout (35° F) Standard
Automatic indoor frost control Standard Standard Standard
Temperature limiting (Max Heat-Max Cool) Electronic 8-step Electronic 8-step Electronic 8-step
Remote thermostat compatibility Standard Standard Standard
Central Desk Control compatibility Standard Standard Standard
2-position discharge grille 45°/65° Standard Standard Standard
Upfront filter (interchangeable) Standard Standard Standard
Manual air vent control Standard Standard Standard
Transfer fan compatibility Optional Optional Optional
Ducted installation
(non Makeup Air module)
Optional NA Optional
Corrosion-treated chassis† Optional Standard Optional
Internal condensate removal (ICR)* Optional
Makeup Air module* Optional NA Optional
*Not for use in corrosive environments
**UPC—Universal Power Cord Connection (see pages 43–45).
***Two-stage heating if using remote thermostat
†Corrosion treatment is standard on all 265V models
265-volt units must be connected in a manner to meet National Electrical Code and all local codes.
Specifications subject to change.
ZONELINE® FEATURES
ARCHITECTS & ENGINEERS DATA MANUAL AZ45/AZ65 SERIES