05-4186A01-eNETL2TUV_Manual_RevD.doc Table of Contents 1 2 3 4 5 6 7 Important Information ............................................................................................................................................................ 3 1.1 RF Exposure ......................................................................................................................................................................... 3 1.2 FCC Approval Notice ..............................................
05-4186A01-eNETL2TUV_Manual_RevD.doc 1 Important Information 1.1 RF Exposure Professional installation required. The radio equipment described in this guide emits radio frequency energy. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come closer than 2.07 meters (6.79 feet) to the antenna when the transmitter is operating in indoor or outdoor environments.
05-4186A01-eNETL2TUV_Manual_RevD.doc 2 Introduction The eNETL2T/U/V is an RF power amplifier designed for use in the 210–270 MHz frequency range at up to 40 Watts. It is intended to serve as a 100% duty cycle amplifier for MDS entraNET 220 and TD220 radios operating in point-to-multipoint repeater or base applications. 2.
05-4186A01-eNETL2TUV_Manual_RevD.doc 3 Interfaces 3.1 J101 Control Interface The J101 Control Interface is intended to connect to the transceiver’s control interface and provides keying and power control signals. Table 1 – J101 Control Cable Pin Functions Pin Pin 1 Pin 2 Pin 3 Pin 4 Function 3 Vdc enable TX, low=off 0.7 Vdc (varies to set RF power) Not used Ground 3.2 J102 RF Output J102 is a 50 Ohm Female Type N connector. 3.3 J103 RF Input J103 is a 50 Ohm Female Type N connector. 3.
05-4186A01-eNETL2TUV_Manual_RevD.doc 4 Installation 4.1 Mounting the Unit The eNETL2T and eNETL2V are designed for mounting in a standard 19–inch rack cabinet using the 3U panel provided. Four screws (not provided) are required to attach the panel to the rack sides. This panel also serves as a heat sink for the PA module, and is normally mounted with the cooling fins facing outward. 4.2 Connecting the Unit Place the amplifier module in service by making the following cable connections. 1. 2. 3. 4. 5.
05-4186A01-eNETL2TUV_Manual_RevD.doc 5 Unit Specifications Table 2 – Unit Specifications Parameter Specification Operating Voltage 10-16 Vdc Maximum Current Draw 6 Amperes @ 12.5V, 40W RF Out. RF Drive Power 100 mW typical, 2W maximum RF Out +40 to +46 dBm (10-40 watts), adjustable Duty Cycle (T, V models) 100% up to full output power Duty Cycle (U model) 100% at 2 Watts, 30% above 2 Watts Operating Frequency 210–270 MHz* Mounting standard 19-inch rack cabinet Approximate Weight 5.15 lbs.