30.05.2007 11:06 Uhr Seite 1 Art. 1770 4000/5 Art. 1772 5000/5 Art. 1774 5000/5 Inox Art. 1775 S 3000/4 NL F GB D 1770-20.
GARDENA Pressure Tank Unit 3000/4, 4000/5, 5000/5, 5000/5 Inox Translation of the original operating instructions from German. Please read these operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the Pressure Tank Unit, its proper use and the safety instructions.
2. Safety instructions Electrical safety: General Information: GB DANGER ! Electric shock ! Risk of injury due to electric shock ! ➔ Always unplug your Garden Pressure Tank Unit before filling, after operation, when troubleshooting and before carrying out any maintenance work.
3. Installation The installation position must be firm and dry, and permit a secure mounting for the pressure tank unit. ➔ Install the pump at a safe distance (min. 2 m) from the pumping medium. The pump must be installed in a location with low air humidity and sufficient ventilation in the area of the ventilation slots. It must be at a distance of at least 5 cm from the walls. No dirt contamination (e.g. sand or earth) may be sucked in through the ventilation slots. The mounting board (e. g.
GB Connect hose to the output side: Note: Use pressure-tight hoses, such as the GARDENA Premium Rubber hose of 19 mm (3/4”) diameter, Art. no. 4432/8452, in connection with the GARDENA Quick-Release Threaded Connector of 33.3 mm (G1) internal thread, Art. no. 7109, and the GARDENA Suction and High Pressure Connector, Art. no. 7120, for 19 mm (3/4”) hoses and a GARDENA Hose Clip, Art. no. 7192. Under no circumstances use these hoses on the suction side.
5. Storage Storage: If there is a risk of frost, the Pressure Tank Unit must be stored where it will not become frozen. 2. Turn the rotary switch to FILL. 3. Unscrew the drain screw . The Pressure Tank Unit will drain down. 4. Store the pressure tank unit in a dry, frost-free place. Store out of the reach of children. Disposal: The unit must not be disposed of with normal household waste but must be disposed of in accordance with local environmental regulations.
Cleaning the check valve: 1. Unplug the pump from the mains. 2. Turn the Pressure Tank Unit upside down. 3. Turn the rotary switch GB 2 1 to FILL. 4. If necessary close all the suction side inlets. 5. Open all pressure side outlets, so that the pressure side is depressurised. 6. Unscrew the drain screw and drain the water. 7. Undo screw and slide the clip upwards 1 and to the rear 2 into the bearing groove. 8. Using a suitable tool, unscrew the check valve cover . 9.
➔ Repair the leak. ➔ Throttle the pump on the pressure side so that the flow quantity on the suction side is governed by that on the pressure side. Suction filter or non-return valve ➔ Clean the suction filter/nonreturn valve. blocked. Pump switches on and off too frequently. Boiler diaphragm is damaged. ➔ Have the boiler diaphragm replaced by GARDENA Service. Pressure in the boiler is too low. ➔ Top up the air in the storage tank.
GB 9. Technical data Type: 3000/4 (Art. no. 1770) 4000/5 (Art. no. 1772) 5000/5 (Art. no. 1774) 5000/5 Inox (Art. no. 1775) Voltage/Frequency: 230 V AC/50 Hz 230 V AC/50 Hz 230 V AC/50 Hz 230 V AC/50 Hz Rated power: 650 W 850 W 1100 W 1200 W Connection cable: 1,5 m H05-RNF 1,5 m H05-RNF 1,5 m H07-RNF 1,5 m H07-RNF Max. delivery capacity: 2800 l/h 3500 l/h 4500 l/h 4500 l/h Max. delivery head: 40 m 45 m 50 m 50 m Max.
1770_20_Hauswwerk_Konf D 30.05.
1770_20_Hauswwerk_Konf D 30.05.2007 9:12 Uhr EU-Konformitätserklärung MaschinenVerordnung (9. GSGVO) / EMVG / Niedersp. RL Der Unterzeichnete GARDENA Manufacturing GmbH · Hans-Lorenser-Straße 40 · D-89079 Ulm bestätigt, dass die nachfolgend bezeichneten Geräte in der von uns in Verkehr gebrachten Ausführung die Anforderungen der harmonisierten EU-Richtlinien, EU-Sicherheitsstandards und produktspezifischen Standards erfüllen.
1770_20_Hauswwerk_Konf 30.05.
1770_20_Hauswwerk_Konf Deutschland/Germany GARDENA Manufacturing GmbH Service Center Hans-Lorenser-Straße 40 D-89079 Ulm Produktfragen: (+49) 731 490-123 Reparaturen: (+49) 731 490-290 service@gardena.com Argentina Argensem S.A. Calle Colonia Japonesa s/n - (1625) Loma Verde, Escobar, Buenos Aires Phone: (+54) 34 88 49 40 40 info@argensem.com.ar Australia Nylex Consumer Products 50-70 Stanley Drive Somerton, Victoria, 3062 Phone: 1800 658 276 spare.parts@nylex.com.