GAT NET.Lock 7000 System Electronic RFID Locker Locks Installation, Configuration, Operation Document Version 3.3 www.gantner.
GAT NET.Lock 7000 System 2 HB_GAT-NETLOCK7000--US_33 www.gantner.
GAT NET.Lock 7000 System Copyright 2014-2015, GANTNER Electronic GmbH, Schruns (Austria). ! General warning and safety instructions Dear customer, We congratulate you on having selected a product (appliance or software) from GANTNER Electronic GmbH. Our aim is to ensure that our product operates with safety and to your complete satisfaction. To achieve this aim we take this opportunity to familiarise you with the following guidelines: 1.
GAT NET.Lock 7000 System 14. However, even if you just want to tell us that everything has functioned perfectly, we still look forward to hearing from you. We wish you a successful application of our product and look forward to welcoming you again as a customer soon. Contact address / manufacturer: GANTNER Electronic GmbH Montafonerstrasse 8 A - 6780 Schruns/Austria Tel.: +43 5556 73784 - 442 Fax: +43 5556 73784 - 8020 Email: info.leisure@gantner.com Website: www.gantner.
GAT NET.Lock 7000 System Table of Contents TABLE OF CONTENTS 1. INTRODUCTION ............................................................................................................................................7 1.1 About this Manual ...................................................................................................................................7 1.2 Contact & Inquiries ................................................................................................................
GAT NET.Lock 7000 System Table of Contents 5.5.1 Slave Controller ............................................................................................................................. 37 5.5.2 Master Controller ........................................................................................................................... 37 5.6 GAT Relaxx - Operation Software for GAT NET.Lock 7000 System ................................................... 38 5.6.3 User Interface ........................
GAT NET.Lock 7000 System Introduction 1. INTRODUCTION 1.1 About this Manual This manual contains all the necessary information required to install GAT NET.Lock 7000 RFID locks into lockers/depots. Operating instructions for the end user are also fully explained. In order to use GAT NET.Lock 7000 locks, a GAT NET.Controller S 7000 slave controller, a GAT NET.Controller M 7000 master controller with their associated network and power cabling are required.
GAT NET.Lock 7000 System General Information 2. GENERAL INFORMATION 2.1 System Parts The GAT NET.Lock 7000 system consists of the following system parts: 2. GAT NET.Lock BoltSet 7100 (For non-metallic doors) 1. GAT NET.Lock 7000 3. GAT NET.Lock BoltSet 7200 (For metallic doors. Includes label carrier) + 4. GAT NET.Controller S 7000 (Slave Controller) 7. GAT NET.Power Cord US (US power cable for GAT NET.Power Supply 100-240 V) 5. GAT NET.Controller M 7000 (Master Controller) 9. GAT NET.
GAT NET.Lock 7000 System General Information 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 2.2 GAT NET.Lock 7000 Electronic RFID locker lock without connection cable and without bolt set. GAT NET.Lock BoltSet 7100 Bolt set with door shackle and booster. Used for non-metallic doors. The bolt set is mounted on the inside of the locker door. GAT NET.Lock BoltSet 7200 Bolt set with door shackle and booster. Used for metallic doors. The bolt set is installed into locker door.
GAT NET.Lock 7000 System General Information 10 HB_GAT-NETLOCK7000--US_33 www.gantner.
GAT NET.Lock 7000 System General Information 2.3 Basic Function of the GAT NET.Lock 7000 System The GAT NET.Lock 7000 lock is the ideal solution for the convenient electronic locking of wardrobe lockers in fitness clubs, baths, golf resorts, hotels and other individual company applications. Operation of the GAT NET.Lock 7000 is carried out using contactless RFID data carriers (Radio Frequency Identification). The GAT NET.Lock 7000 is suitable for any type of locker material (e.g.
GAT NET.Lock 7000 System General Information FID (Company ID) and Site Key: LEGIC systems use an FID number. In MIFARE systems a site key is used which is a combination of the FID and the read and write keys. The FID and site keys are unique numbers for every leisure facility installation. These numbers are encoded in every data carrier and device and with this number it can be guaranteed that data carriers of one installation are not used in other installations. Slave Controller: The GAT NET.
GAT NET.Lock 7000 System Mounting 3. MOUNTING This mounting instruction describes how to install the GAT NET.Lock 7000 locker locks. Please read this instruction carefully and follow it prior to working on the lockers or installing the locks. As there is a wide variety of applications and locker types, a test installation including a functional testing must always be performed prior to the serial production of the lockers and the installation of the locks (see chapter "3.8. Test Installation").
GAT NET.Lock 7000 System Mounting 3.2 Metallic and Non-Metallic Doors Because the RFID field of the GAT NET.Lock 7000 is distorted or blocked by metal (e.g. with metallic locker doors), a cut-out has to be made in metallic locker doors into which the GAT NET.Lock Bolt Set 7200 and the label carrier can be installed. A specific cut-out for non-metallic doors is not necessary, only a drill hole for the LED field is required. Since the reading range of the GAT NET.
GAT NET.Lock 7000 System Mounting 3.3.2 Basic Dimensions of GAT NET.Lock 7000 and the GAT NET.Lock Bolt Sets Figure 3.3 - Dimensions of the GAT NET.Lock 7000 with GAT NET.Lock BoltSet 7100 for non-metallic doors Figure 3.4 - Dimensions of the GAT NET.Lock 7000 with GAT NET.Lock BoltSet 7200 for metallic doors www.gantner.
GAT NET.Lock 7000 System Mounting 1. 2. 3. 4. 5. 6. 7. 8. 3.4 GAT NET.Lock 7000 GAT NET.Lock BoltSet 7100 (for non-metallic doors) GAT NET.Lock BoltSet 7200 (for metallic doors) Door shackle Door contact Booster Status LED Label carrier Door Status Contact The GAT NET.Lock 7000 has a feedback function which is activated by the door contact (5) on the bolt set as soon as the locker door is closed. To guarantee the correct functionality of the GAT NET.
GAT NET.Lock 7000 System Mounting 3.5 Mounting in Lockers with Non-Metallic Doors In lockers with non-metallic doors the GAT NET.Lock 7000 is mounted on the left or right inner locker wall (depending if it is a right or left locker) and the GAT NET.Lock Bolt Set 71x0 is mounted on the inside of the locker door. Drilling of the locker door is also required for the LED status display. See the diagram below and the steps afterwards for the mounting instructions. 1. 2. 3. 4. 5. 6. 7. GAT NET.
GAT NET.Lock 7000 System Mounting - The cabinet door, the bolt set and the front side of the GAT NET.Lock 7000 must be perpendicular and parallel to each other. If not, the door contact in the GAT NET.Lock 7000, and therefore the lock itself, can potentialy not function correctly. - If right and left doors are used in a mix, please note the LED positions, since the GAT NET.Lock 7000 is mounted upside-down on the left doors, compared to the right doors. Figure 3.6 - LED positions of GAT NET.
GAT NET.Lock 7000 System Mounting Mount the GAT NET.Lock 7000 with 3 screws (3) on the inside locker wall. Note: Use the correct screws according to the type of locker material. Attention: The maximum allowed tightening torque of the screws is 2 Nm. Drill 3 holes (6 in Figure 3.5) on the locker door inside for mounting the GAT NET.Lock BoltSet 7100. Drill a hole for the LED display in the locker door (7 in Figure 3.5). The recommended drill hole diameter is 10 mm.
GAT NET.Lock 7000 System Mounting 3.6 Mounting in Lockers with Metallic Doors In lockers with metallic doors the GAT NET.Lock 7000 is mounted on the left or right inner locker wall (depending if it is a right or left locker). 2 cut-outs have to be made in the door - one on the inside door sheet and one on the outside door sheet. The two parts of the GAT NET.Lock Bolt Set 7200 are then mounted into the locker door. See the following figure and the steps afterwards for the mounting instructions. 1. 2. 3.
GAT NET.Lock 7000 System Mounting 3.6.1 Cut-Outs in the Locker Door On the inside and outside walls of the locker door the following cut-outs must be made in order to mount the GAT NET. Lock BoltSet 7200 and the label carrier. The measurements for the cut-outs are as follows. Figure 3.8 - Cut-Outs in Metallic Doors 3.6.2 Important Measurements when Mounting the GAT NET.
GAT NET.Lock 7000 System Mounting Before installing all locks in a new locker system, a test installation of one lock in a mechanically identical locker and a subsequent function check must be performed as described below. Only after a successful test installation has been performed may the remaining locks be installed in the same way. There is an installation certificate available which will assist with this process (Installation Certificate GAT Lock 7xxx.pdf). 3.6.3 Steps for Mounting the GAT NET.
GAT NET.Lock 7000 System Mounting Note: A label is available to cover the LED hole. The label has a transparent (matt) viewing window for the LED to shine through and can be ordered with a standard GANTNER or customer specific design. Figure 3.9 - Label carrier with front label Close the door to test if the locker door can be closed easily and the door shackle inserts into the opening of the GAT NET.Lock 7000. 3.7 Points to be observed during Installation Fastening screws: The GAT NET.
GAT NET.Lock 7000 System Mounting 3.8 Test Installation As the GAT NET.Lock 7000 is suitable for a wide range of installation applications, always perform a test installation and functional testing of the GAT NET.Lock 7000 in a finished sample locker from the facility before starting with the serial production of the lockers. In particular, test if the door shackle slides centrally into the opening of the GAT NET.
GAT NET.Lock 7000 System Mounting 3.10.1 Instructions for Mounting the GAT NET.Controller M 7000 und S 7000: Observe the measurements shown in Figure 3.10 and drill 3 holes for the controller mounting points. Use the correct drill diameter required by the screws and/or wall plugs (screws up to max. M4). Screw in the top two screws until the head remains approximately 5mm out from the wall. Attach the controller housing to the top two screws and push down until the housing stops against the screws.
GAT NET.Lock 7000 System Mounting 26 HB_GAT-NETLOCK7000--US_33 www.gantner.
GAT NET.Lock 7000 System Electrical Connection 4. ELECTRICAL CONNECTION This chapter describes the electrical connections required between the GAT NET.Lock 7000 and the GAT NET.Controller S 7000 and GAT NET.Controller M 7000 control units. Electrical connections must only be done in a powerless state and only by trained and specialised personnel. 4.1 System Structure The GAT NET.Lock 7000 is always connected to the GAT NET.Controller S 7000 slave controller.
GAT NET.Lock 7000 System Electrical Connection 4.2 Cable Connection of the GAT NET.Lock 7000 Back Side Figure 4.2 - Cable connection at the GAT NET.Lock 7000 4.2.1 Connection Cable The 4 m GAT NET.Lock Cable 4m (part no. 321826) connection cable is included in the scope of supply. This cable is used to connect the GAT NET.Lock 7000 to a GAT NET.Controller S 7000 slave controller. The cable has a 4-pin MOLEX plug type Micro-Fit 3.0TM on both ends.
GAT NET.Lock 7000 System Electrical Connection 4.3 Connections at the Slave Controller GAT NET.Controller S 7000 4.3.1 GAT NET.Lock 7000 Connection The GAT NET.Lock 7000 locks are connected via the 4-pin MOLEX connectors on the side panel of the GAT NET.Controller S 7000. Attention, always use original cables from GANTNER Electronic GmbH. The lock connection cable must not be modified (shortened or extended) in any way. If the cable is too short, only one GAT Net.Lock Cable 4m (part no.
GAT NET.Lock 7000 System Electrical Connection Observe the following values for the number of connectable controllers per interface: - A maximum of 8 slave controllers per RS 485 line - Maximum of one RS 485 line length = 200 m Figure 4.5 - Maximal RS 485 line length It is important to differentiate between the RS 485 IN and OUT plugs.
GAT NET.Lock 7000 System Electrical Connection 4.3.3 Power Supply The GAT NET.Controller S 7000 is connected to the mains power supply via an external power supply unit. Depending on the type of power supply unit and the country, mains voltage may be UAC 230 V or UAC 115 V (please refer to technical data). The power supply is connected to the controller via the MOLEX plug shown in Figure 4.7. Figure 4.7 - Connection of the power supply on the GAT NET.
GAT NET.Lock 7000 System Electrical Connection Figure 4.9 - Examples for power supply 4.3.4 LED Signals and Buttons For the display of the operating state and to start certain functions various LED indicators and buttons are provided on the GAT NET.Controller S 7000. Yellow LED Green LED Figure 4.10 - LEDs and buttons provided on the GAT NET.Controller S 7000 LEDs - RS 485 IN (yellow): The connection with the master controller has been established. - RS 485 IN (green): RS 485 communication is active.
GAT NET.Lock 7000 System Electrical Connection 4.4 Connections on the GAT NET.Controller M 7000 Master Controller 4.4.1 Connecting the GAT NET.Controller S 7000 Slave Controllers to the Master Controller The slave controllers are connected to the master controllers via the RS 485 interface using RJ 45 plugs. The connection must be made through the "RS 485 SLAVES" socket. Figure 4.11 - Connection of the GAT NET.Controller S 7000 at the GAT NET.
GAT NET.Lock 7000 System Electrical Connection 4.4.3 Connection of the Power Supply The GAT NET.Controller M 7000 is connected via an external power supply unit to the mains power supply, i.e. depending on the type of unit and the country of use UAC 230 V or UAC 115 V (please refer to technical data). The power supply is connected to the controller via the MOLEX plug. Figure 4.13 - Power supply on the GAT NET.
GAT NET.Lock 7000 System Configuration and Operation 5. CONFIGURATION AND OPERATION 5.1 Antenna Adjustment of the GAT NET.Lock 7000 The antenna of the GAT NET.Lock 7000 must be adjusted so that an optimal reading range for the RFID data carriers is obtained. The antenna adjustment does not need to be done by hand as the GAT NET.Lock 7000 supports automatic antenna adjustment via PC software.
GAT NET.Lock 7000 System Configuration and Operation 5.3 Restart a Controller GAT NET.Controller S 7000 or GAT NET.Controller M 7000 In certain situations (e.g. after an error or network problems) it may be helpful to restart a master or slave controller. This means that the software application in these devices will be restarted.
GAT NET.Lock 7000 System Configuration and Operation 5.5 Status Information for the GAT NET.Controller S 7000 and GAT NET.Controller M 7000 LED 2 shows the following status information at a slave and master controller. 5.5.
GAT NET.Lock 7000 System Configuration and Operation 5.6 GAT Relaxx - Operation Software for GAT NET.Lock 7000 System Note: This chapter includes only a short overview of the software and its main functions. A detailed description of all GAT Relaxx functions is included as interactive help within GAT Relaxx. For installation, general information and system requirements, an installation manual is also available and included on the GAT Relaxx installation CD.
GAT NET.Lock 7000 System Configuration and Operation Hardware View 1 2 3 4 5 7 6 8 9 Figure 5.15 - GAT Relaxx, Hardware View The hardware view is divided into the following areas: 1 - Main menu: 2 - Symbol bar: 3 - Switch user interface: 4 - Selective symbol bar: 5 - System overview: 6 - Locker overview: 7 - Information area: 8 - Locker actions: 8 - Status bar: www.gantner.com Access to all GAT Relaxx functions by selecting the corresponding menu items. Fast access to the main functions.
GAT NET.Lock 7000 System Configuration and Operation Organization View 5 7 6 8 Figure 5.16 - GAT Relaxx, Organization View The areas (5), (6) and (7) serve a somewhat different purpose in the user interface: 5 - System overview: 6 - Locker overview: 7 – Information area: 40 HB_GAT-NETLOCK7000--US_33 Here the lockers within a system are divided logically into "areas", (e.g. "male locker room" and "female locker room").
GAT NET.Lock 7000 System Technical Data 6. TECHNICAL DATA 6.1 GAT NET.Lock 7000 Nominal voltage UDC: Power supply: Average power consumption: RFID frequency: Retaining force: Force on inner side of the door: User guidance: Interface: Number of locks per slave controller: Connectors: Housing material: Door width: Dimensions: Permitted ambient temperature: Protection type: Protection class: Weight: Environment class based on VDS 2110: 6.2 5V Via connection cable from the slave controller 60 mW 13.
GAT NET.Lock 7000 System Technical Data 6.3 GAT NET.
GAT NET.Lock 7000 System Technical Data FCC INFORMATION (U.S.A.) GAT NET.Controller S 7000 F/ISO Note: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. GAT NET.Controller M 7000 F/ISO and GAT NET.
GANTNER Electronic GmbH GANTNER Electronic GmbH Deutschland GANTNER Electronics PTY LTD Australia Montafonerstraße 8 Industriestraße 40F Unit 6 15/17 Chaplin Drive, West Lane Cove 6780 Schruns, Austria 44894 Bochum, Germany Sydney NSW 2006, Australia T +43 5556 73784-0 T +49 234 58896-0 T +61 2 9011 8114 F +43 5556 73784-8000 F +49 234 58896-11 F +61 2 8209 1708 info@gantner.com info-de@gantner.com info-aus@gantner.com GANTNER Electronics Ltd.