Gallagher T15 Reader Installation Note T15 MIFARE® Reader, Black: C300470 T15 MIFARE® Reader, White: C300471 T15 Multi Tech Reader, Black: C300480 T15 Multi Tech Reader, White: C300481 3E4237 Gallagher T15 Reader | Edition 11 | February 2022 Copyright © Gallagher Group Limited T15 PIV Reader, Black: C305470 T15 PIV Reader, White: C305471 T15 PIV Reader - Multi Tech, Black: C305480 T15 PIV Reader - Multi Tech, White: C305481 Page 1
Disclaimer This document gives certain information about products and/or services provided by Gallagher Group Limited or its related companies (referred to as "Gallagher Group"). The information is indicative only and is subject to change without notice meaning it may be out of date at any given time.
Contents 1 Introduction...................................................................................................................................... 4 2 Before you begin............................................................................................................................... 4 3 Distance between readers................................................................................................................ 7 4 Installation..........................................
1 Introduction The Gallagher T15 Reader is a smart card and Bluetooth® low energy technology reader. It can be installed as either an entry reader or exit reader. The reader sends information to the Gallagher Controller and acts upon information sent from the Gallagher Controller. The reader itself does not make any access decisions. The reader is available in ten variants. The supported technologies and compatibility for each variant is shown in the table below.
2 Before you begin 2.1 Shipment contents Check the shipment contains the following items: 2.2 • 1 x Gallagher T15 Reader facia assembly • 1 x Gallagher T15 Reader bezel • 1 x M3 Torx Post Security screw • 2 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws • 2 x 40 mm No.6 self tapping, pan head, Phillips drive fixing screws Power supply The Gallagher T15 Reader is designed to operate over a supply voltage of 13.6 Vdc measured at the reader terminals.
"T" or "Star" circuits are not permitted between HBUS devices HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Controller 6000 Connect the on-board termination jumper Terminate HBUS Device HBUS Device RS485 1 "T" or "Star" circuits are not permitted between HBUS devices RS485 1 HBUS Device HBUS Device Controller 6000 Terminate Remove the on-board termination jumper Terminate HBUS Device Controller 6000 HBUS Device H1 H5 HBUS Device H4 H8 HBUS Device HBUS Module Terminat
Cable distance Cable type Cable format* HBUS single reader connected using data only in a single cable Cardax IV single reader connected using data only in a single cable*** CAT 5e or better** 4 twisted pair each 2 x 0.2 mm2 (24 AWG) 500 m (1640 ft) 200 m (650 ft) 100 m (330 ft) BELDEN 9842** (shielded) 2 twisted pair each 2 x 0.2 mm2 (24 AWG) 500 m (1640 ft) 200 m (650 ft) 100 m (330 ft) SEC472 4 x 0.
4 Installation ATTENTION: This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing. The Gallagher T15 Reader is designed to be mounted on any solid flat surface. However installation on metal surfaces, particularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal surface.
An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000). A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (attached to a Controller 6000) or a Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI).
Hint: After removal of the security screw, press the top of the facia. The bottom of the facia will exit the reader bezel. 8. 5 6 Configure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to the topic "Configuring HBUS Devices" in the Command Centre Configuration Client Online Help. If the reader is connected as a Cardax IV Reader, refer to the topic "Creating Readers" in the Command Centre Configuration Client Online Help.
7 Technical specifications Routine maintenance: Not applicable for this reader Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth Voltage: 13.
8 Approvals and Compliance Standards This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
9 mm (5.47") 13 mm (1/2") diameter hole for cable 16 mm (0.63") 44 mm (1.73") Mounting dimensions 67 mm (2.64") 9 44 mm (1.73") IMPORTANT This picture is not to scale, therefore use the measurements provided.