Gallagher T15 Terminal Installation Note T15 Mifare Reader Black: C300470 T15 Mifare Reader White: C300471 T15 Multi Tech Reader Black: C300480 T15 Multi Tech Reader White: C300481 3E4237 Gallagher T15 Reader | Edition 1 | June 2016 Copyright © Gallagher Group Limited T15 PIV Mifare Reader Black: C305470 T15 PIV Mifare Reader White: C305471 T15 PIV Multi Tech Reader Black: C305480 T15 PIV Multi Tech Reader White: C305481 Page 1
Disclaimer This document gives certain information about products and/or services provided by Gallagher Group Limited or its related companies (referred to as "Gallagher Group"). The information is indicative only and is subject to change without notice meaning it may be out of date at any given time.
Contents 1 Introduction...................................................................................................................................... 4 2 Before you begin............................................................................................................................... 4 3 Distance between proximity readers................................................................................................ 7 4 Installation................................................
1 Introduction The Gallagher T15 Reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader. The reader contains an NXP chip for improved read range performance and supports Bluetooth® technology for hands-free access. The reader sends information to the Gallagher Controller and acts upon information sent from the Gallagher Controller. The reader itself does not make any access decisions. The reader is available in eight variants.
2.2 Power supply The Gallagher T15 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals. The operating current draw is dependant on the supply voltage at the reader. The power source should be linear or a good quality switched-mode power supply. The performance of the reader may be affected by a low quality, noisy power supply. 2.3 Cabling The Gallagher T15 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded security cable.
HBUS Device HBUS Device "T" or "Star" circuits are not permitted between HBUS devices RS485 1 HBUS Device HBUS Device Controller 6000 Terminate Remove the on-board termination jumper Terminate HBUS Device HBUS Device "T" or "Star" circuits are not permitted between HBUS devices Controller 6000 HBUS Device H1 H5 HBUS Device H4 H8 HBUS Device HBUS Module Terminate HBUS Device Terminate HBUS Device HBUS Device Terminate Terminate Cable distance Cable type Cable format* CAT 5e or bet
Notes: 3 • Shielded cable may reduce the obtainable cable length. Shielded cable should be grounded at the Controller end only. • If other cable types are used, operating distances and performance may be reduced depending on the cable quality. • HBUS allows up to 20 readers to be connected to a single cable. Each reader requires at least 9 Vdc to function correctly. The cable length and the number of readers connected will have an impact on the voltage at each reader.
4 Installation ATTENTION: This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing. The Gallagher T15 Reader is designed to be mounted on any solid flat surface. However installation on metal surfaces, particularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal surface. The recommended mounting height for the reader is 1.
A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (attached to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or a Gallagher Local Bus Reader I/O Interface.
5 7. Removal of the facia assembly is a simple reversal of these steps. 8. Configure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to the topic "Configuring HBUS Devices" in the Command Centre Configuration Client Online Help. If the reader is connected as a Cardax IV Reader, refer to the topic "Creating Readers" in the Command Centre Configuration Client Online Help.
7 Technical specifications Routine maintenance: Not applicable for this reader Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth Voltage: 9 Vdc - 16 Vdc Current: Mifare Reader Idle 1 2 3 1 Maximum Multi Tech Reader 2 Idle 1 Maximum 2 at 9 Vdc 124 mA 175 mA 115 mA 164 mA at 13.
8 Approvals and standards This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
9 mm (5.47") 13 mm (1/2") diameter hole for cable 16 mm (0.63") 44 mm (1.73") Mounting dimensions 67 mm (2.64") 9 44 mm (1.73") IMPORTANT This picture is not to scale, therefore use the measurements provided.