Gallagher T11 Reader Installation Note T11 Mifare Reader Black: C300410 T11 Mifare Reader White: C300411 T11 Multi Tech Reader Black: C300430 T11 Multi Tech Reader White: C300431 3E4289 Gallagher T11 Reader | Edition 1 | August 2016 Copyright © Gallagher Group Limited T11 PIV Reader Black: C305410 T11 PIV Reader White: C305411 T11 PIV Reader - Multi Tech Black: C305430 T11 PIV Reader - Multi Tech White: C305431 Page 1
Disclaimer This document gives certain information about products and/or services provided by Gallagher Group Limited or its related companies (referred to as "Gallagher Group"). The information is indicative only and is subject to change without notice meaning it may be out of date at any given time.
Contents 1 Introduction...................................................................................................................................... 4 2 Before you begin............................................................................................................................... 5 3 Distance between readers................................................................................................................ 7 4 Installation..........................................
1 Introduction The Gallagher T11 Reader is a mobile credential and smart card proximity reader. It can be installed as either an entry reader or exit reader. It can be mounted on a vertical, rectangular 50 mm x 75 mm (2" x 3") flush box with mounting holes spaced at a nominal 85 mm (3.25"). The reader sends information to the Gallagher Controller and acts upon information sent from the Gallagher Controller. The reader itself does not make any access decisions. The reader is available in eight variants.
2 Before you begin 2.1 Shipment contents Check the shipment contains the following items: 2.2 • 1 x Gallagher T11 Reader facia assembly • 1 x Gallagher T11 Reader bezel • 1 x M3 Torx Post Security screw • 2 x 6-32 UNC Phillips drive fixing screws • 4 x 25 mm No.6 self tapping, pan head, Phillips drive fixing screws • 4 x 40 mm No.
"T" or "Star" circuits are not permitted between HBUS devices HBUS Device HBUS Device HBUS Device HBUS Device HBUS Device Controller 6000 Connect the on-board termination jumper Terminate HBUS Device HBUS Device RS485 1 HBUS Device "T" or "Star" circuits are not permitted between HBUS devices RS485 1 HBUS Device Controller 6000 Terminate Remove the on-board termination jumper Terminate HBUS Device HBUS Device "T" or "Star" circuits are not permitted between HBUS devices Controller 6000
Cable distance Cable type Cable format* CAT 5e or better** HBUS single reader connected using data only in a single cable Cardax IV single reader connected using data only in a single cable*** HBUS/Cardax IV single reader connected using power and data in a single cable 4 twisted pair 500 m (1640 ft) Each 2 x 0.2 mm2 (24 AWG) 200 m (650 ft) 100 m (330 ft) BELDEN 9842** 2 twisted pair 500 m (1640 ft) (shielded) Each 2 x 0.2 mm2 (24 AWG) 200 m (650 ft) 100 m (330 ft) SEC472 4 x 0.
4 Installation ATTENTION: This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing. The Gallagher T11 Reader is designed to be mounted on vertically orientated electrical flush (gang) boxes, or any solid flat surface. However installation on metal surfaces, particularly those with a large surface area will reduce read range.
Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only. An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (attached to a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
5 6 7. Removal of the facia assembly is a simple reversal of these steps. 8. Configure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to the topic "Configuring HBUS Devices" in the Command Centre Configuration Client Online Help. If the reader is connected as a Cardax IV Reader, refer to the topic "Creating Readers" in the Command Centre Configuration Client Online Help.
7 Technical specifications Routine maintenance: Not applicable for this reader Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth Voltage: 9 Vdc - 16 Vdc Current: Mifare Reader Idle 1 2 3 1 Maximum Multi Tech Reader 2 Idle 1 Maximum 2 at 9 Vdc 124 mA 175 mA 115 mA 164 mA at 13.
8 Approvals and standards This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
9 Mounting dimensions Mifare Card read area 32 mm (1.26") 115 mm (4.53") 40 mm (1.57") 48 mm (1.89") 13 mm (1/2") diameter hole for cable 22.5 mm (0.89") 125 Card read area 40 mm (1.57") 70 mm (2.76") IMPORTANT This picture is not to scale, therefore use the measurements provided.